General Purpose Relays
MKS
Exceptionally Reliable General Purpose
Relay now available with Lockable Test
Button
• IEC Rating of 7A 250 V AC 50/60 Hz,
General use 100,000 cycles.
• Mechanical indicator standard for all models.
• Optional features include lockable test button, LED
indicator, diode surge suppression, varistor, reverse
polarity, and alternate wiring styles.
• UL (RU/
C
RU), CE and TUV approved.
• RoHS Compliant.
Features
Two-way Action Test Button (Models with Lockable Test Button)
Relay in
Normal Operation
For Momentary
Operation
For Lock
Operation
Yellow
button
Slide the latching lever
to the first position,
then press the yellow
button with
an insulated
tool to operate the
contact.
Slide the latching lever
to the second position.
(The contact is now in
the locked position.)
Note:
The latching lever is Red for AC Coil versions and Blue for DC Coil versions.
Model Number Structure
■
Model Number Legend
MKS@@@@@-@-@
1 2 3 4 5
6
7
5. Coil Polarity
Blank: Standard
1:
Reverse polarity (DC coil only)
6. Surge Absorption
Blank:Standard
D:
Surge absorber diode (DC coil only)
V:
Surge absorber varistor (AC coil only)
7. Internal Connections DPDT
Blank: Standard
2 or 5: Non-standard connections.(Refer to “Terminal
Arrange-
ment/Internal Connection (Bottom View)”.)
8. Rated Voltage
(Refer to
“Coil Ratings”.)
1. Contact Form
2:
DPDT
3:
3PDT
2. Terminals
P:
Plug-in
3. Mechanical Indicator/Test Button
Blank:Mechanical indicator
I:
Mechanical indicator and lockable test button
4. LED Indicator
Blank: Standard
N:
LED indicator
General Purpose Relays
MKS
299
■
Characteristics
Contact resistance
Operate time
Release time
Max. operating frequency
Insulation resistance
Dielectric strength
100 mΩ max.
AC: 20 ms max.
DC: 30 ms max.
20 ms max.(40 ms max. for built-in diode models)
Mechanical: 18,000 operations/hr (no load)
Electrical:1,800 operations/hr (at rated load)
100 MΩ min. (at 500 VDC)
2,500 VAC 50/60 Hz for 1 min. between coil and contacts
1,000 VAC 50/60 Hz for 1 min. between contacts of same polarity and terminals of the same polarity
2,500 VAC 50/60 Hz for 1 min. between current-carrying parts, non-current-carrying parts, and opposite
polarity
Basic insulation
4.5 kV between coil and contacts (with 1.2
×
50
μs
impulse wave)
3.0 kV between contacts of different polarity (with 1.2
×
50
μs
impulse wave)
3
250 V
Destruction:10 to 55 Hz, 1.5 mm double amplitude
Malfunction:10 to 55 Hz, 1.0 mm double amplitude
Destruction:1,000 m/s
2
(approx. 100 G)
Malfunction:100 m/s
2
(approx. 10 G)
Mechanical: 5,000,000 operations min.
Electrical:100,000 operations min.
10 mA at 1 VDC P level:
λ
60
=0.1 x 10
-6
/ ops
Operating: –40 to 60°C (with no icing or condensation)
Operating: 5% to 85%
Approx. 90 g
Insulation method
Impulse withstand voltage
Pollution degree
Rated insulation voltage
Vibration resistance
Shock resistance
Life expectancy
Min. permissible load
Ambient temperature
Ambient humidity
Weight
Note: 1.
The values given above are initial values.
2.
Ambient temperature of models with LED indicator is
−25
to 60°C.
■
Approved Standards
Coil ratings
6 to 110 VDC N.O.
6 to 240 VAC contact
N.C.
contact
UL Recognized (File No. E41515) - - Ambient Temp. = 40°C
Contact ratings
Operations
10 A, 250 V AC 50/60 Hz (Resistive) 100,000
10 A, 30 V DC (Resistive)
7 A, 250 V AC 50/60 Hz (General Use)
10 A, 250 V AC 50/60 Hz (Resistive) 100,000
10 A, 30 V DC (Resistive)
7 A, 250 V AC 50/60 Hz (General Use)
IEC Standard/TUV Certification: IEC61810-1
(Certification No. R50104853)
Coil ratings
6, 12, 24, 48, N.O.
100, 110 VDC contact
6, 12, 24, 100,
110, 200, 220,
N.C.
240 VAC
contact
Contact ratings
Operations
10 A, 250 V AC 50/60 Hz (Resistive) 100,000
10 A, 30 V DC (Resistive)
7 A, 250 V AC 50/60 Hz (General Use)
5 A, 250 V AC 50/60 Hz (Resistive)
100,000
5 A, 30 V DC (Resistive)
7 A, 250 V AC 50/60 Hz (General Use)
Note:
10A UL ratings are with no load on the other contact set.
CSA Certified (File No. LR35535)
Coil
ratings
6 to 125 VDC 2
6 to 240 VAC
3
Note:
Maximum carrying current per TUV Certification is 9 A when
new MK-S relays are mounted in PF083A-E or PF113A-E
Sockets.
Operations
100,000
Number
of Poles
Contact ratings
10 A, 250 V AC (Resistive)
10 A, 30 V DC (Resistive)
7 A, 250 V AC (General Use)
10 A, 250 V AC (Resistive)
Same Polarity
10 A, 30 V DC (Resistive)
Same Polarity
7 A, 250 V AC (General Use)
Same Polarity
100,000
302
General Purpose Relays
MKS
Engineering Data
■
Reference Data
Maximum Switching Power
Switching current (A)
100
50
30
DC resistive load
with NO contact
10
5
Rated Carry Current vs. Ambient Rated Temperature
Rated carry current (A)
10
UL derating curve
AC resistive load
with NO contact
5
3
DC resistive
load with
NC contact
1
10
30
AC resistive load
with NC contact
AC inductive
load
(p.f. = 0.4)
50
100
300
500 1.000
0
−40
−20
0
20
40
60
80
Switching voltage (V)
Ambient temperature (°C)
Note:
The lower limit of the ambient operating temperature for models
with built-in operation indicators is
−25°C.
Dimensions
Note:
All units are in millimeters unless otherwise indicated.
Models without Test Button
Models with Lockable Test Button
34.5 max.
34.5 max.
34.5 max.
0.8
52.5 max.
34.5 max.
0.8
52.5 max.
Track Mounted Sockets
See below for Socket dimensions.
Poles
Maximum carry current
2 poles
10 A
PF083A-E
PF083A-D
Finger-protection models
5A
PF083A
—
3 poles
PF113A-E
PF113A-D
PF113A
Note:
If using the PF083A or PF113A Sockets, be sure the maximum carrying current is 5 A or less. When using finger-protection sockets, make
sure the connecting wire terminals are Y-shaped.
General Purpose Relays
MKS
303