Fixed Attenuator, 36000MHz Min, 50000MHz Max, SURFACE MOUNT PACKAGE-4
CategoryWireless rf/communication    Radio frequency and microwave   
File Size538KB,8 Pages
ManufacturerSmiths Group
Download Datasheet Parametric View All

QTVA050N07CSMT Overview

Fixed Attenuator, 36000MHz Min, 50000MHz Max, SURFACE MOUNT PACKAGE-4

QTVA050N07CSMT Parametric

Parameter NameAttribute value
MakerSmiths Group
Reach Compliance Codeunknown
Nominal attenuation5 dB
Characteristic impedance50 Ω
structureCOMPONENT
Maximum input power (CW)23.01 dBm
JESD-609 codee0
Maximum operating frequency50000 MHz
Minimum operating frequency36000 MHz
Maximum operating temperature150 °C
Minimum operating temperature-55 °C
RF/Microwave Device TypesFIXED ATTENUATOR
Terminal surfaceTIN LEAD
Maximum voltage standing wave ratio1.5
DATA SHEET
FEATURES
QTVAXX0NXXXSMTF
APPLICATIONS
Point to Point Radios
Phased Array Radar
High Frequency Transceivers
Up/Down Converters
Software Defined Radios
REV 07/28/2010
36 – 50 GHz
Surface Mount for Pick and Place Assembly
1206 Small Footprint
RoHS Compliant Versions
Available on Tape & Reel
Same Footprint, Fixed Versions Available
GENERAL DESCRIPTION
The QTVA is a one of a kind, temperature variable high frequency surface mount device developed for applications where
specific signal level control is required. Being passive in nature, there is no distortion, phase shift or time delay. The
attenuator structure is internally tuned for optimum performance beyond Ka band, with the added benefit of being a truly
symmetrical, bidirectional attenuator. The QTVA comes in two styles, microstrip and coplanar.
ELECTRICAL SPECIFICATIONS
(1)
QTVAXXXNXXXSMTF
Frequency
GHz
36 – 50
Impedance
50
Attenuation
dB
0, 3 – 10
Attenuation
Accuracy
dB
± 0.5
Temperature
Coefficient
(2)
10
-3
dB/dB/°C
3, 5, 7
Temperature
Coefficient
Tolerance
10
-3
dB/dB/°C
±1
Power
Handling
(3)
mWatts CW
200
VSWR
Max
1.50
Operating
Temperature
°C
-55 to +150
Specification Notes:
(1) Measured on EMC Technology test fixture. Specifications are subject to change without notice.
(2) TCA = (LINEAR REGRESSION SLOPE) / (ATTENUATION @ 25°C).
Calculate linear regression slope from attenuation versus temperature from -55°C to +125°C in 20°C increment.
(3) Full rated power to 125°C, derated linearly to 0 Watts at 150°C
PART NUMBERING
emc-rflabs.com • +1 772-286-9300
AS 9100, ISO 9001 and ISO 14001 Certified

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号