Chip tantalum capacitors
TCT Series CL Case
Features (CL)
1) Vital for all hybrid integrated circuits
board application.
2) Wide capacitance range.
3) Screening by thermal shock.
Dimensions
(Unit : mm)
Anode mark
(Unit : mm)
Dimensions
L
W
1
W
2
H
CL case
6.0
+
0.2
−
3.2
+
0.2
−
2.2
+
0.2
−
1.4
+
0.1
−
1.3
+
0.2
−
+
−
S
Part No. Explanation
T C T
1
C L
2
1 A
3
1
5
4
7
M
5
C R
6
1
Series name
TCT
4
Nominal capacitance
Nominal capacitance in pF in 3 digits:
2 significant figures followed by the figure
representing the number of 0's.
5
Capacitance tolerance
2
Case style
TC
CL
3
Rated voltage
Rated voltage (V)
CODE
2.5 4 6.3 10 16 20 25
0E 0G 0J 1A 1C 1D 1E
M :
+
20%
−
6
Taping
C : Tape width (12mm)
R :
Positive electrode on the side opposite to sprocket hole
Rated table
Rated voltage (V)
(µF)
10 (106)
100 (107)
150 (157)
220(227)
330(337)
470(477)
CL
CL
2.5
0E
4
0G
6.3
0J
10
1A
16
1C
20
1D
25
1E
35
1V
∗
CL
∗
CL
∗
CL
∗
CL
Remark) Case size codes (CL) in the above show products line-up.
∗
Under development
www.rohm.com
c
○
2009 ROHM Co., Ltd. All rights reserved.
1/5
2009.01 - Rev.D
TCT Series CL Case
Marking
The indications listed below should be given on the surface of a capacitor.
(1) Polarity
(2) Rated DC voltage
(3) Visual typical example
Data Sheet
(1) capacitance code
(2) voltage code
[CL case]
note 1)
10V
(1)
150
(2)
150
10V
note 2) voltage code and capacitance code are variable with parts number
Characteristics
Item
Operating Temperature
Maximum operating
temperature with no voltage
derating
Performance
−55°C
to
+125°C
+85°C
2.5 4 6.3 10 16 20 25 35
1.6 2.5 4 6.3 10 13 16 22
3.2 5.0 8 13 20 26 32 44
Shall be satisfied the voltage on
" Standard list "
Test conditions (based on JIS C 5101−1 and JIS C 5101−3)
Voltage reduction when temperature exceeds
+
85
°C
Rated voltage (VDC)
Category voltage (VDC)
Surge voltage (VDC)
DC Leakage current
at 85
°C
at 125
°C
at 85
°C
As per 4.9 JIS C 5101-1
As per 4.5.1 JIS C 5101-3
Voltage : Rated voltage for 5min
As per 4.7 JIS C 5101-1
As per 4.5.2 JIS C 5101-3
Measuring frequency : 120±12Hz
Measuring voltage : 0.5Vrms
+1.5
to 2V.DC
Measuring circuit
: DC Equivalent series circuit
As per 4.8 JIS C 5101-1
As per 4.5.3 JIS C 5101-3
Measuring frequency : 120±12Hz
Measuring voltage : 0.5Vrms
+1.5
to 2V.DC
: DC Equivalent series circuit
Measuring circuit
As per 4.10 JIS C 5101-1
As per 4.5.4 JIS C 5101-3
Measuring frequency : 100±10kHz
Measuring voltage : 0.5Vrms or less
: DC Equivalent series circuit
Measuring circuit
As per 4.14 JIS C 5101-1
As per 4.6 JIS C 5101-3
Dip in the solder bath
Solder temp
: 260±5
°C
Duration
: 5±0.5s
Repetition
:1
After the specimens, leave it at room temperature for
over 24h and then measure the sample.
As per 4.16 JIS C 5101-1
As per 4.10 JIS C 5101-3
Repetition : 5 cycles
(1 cycle : steps 1 to 4) without discontinuation.
1
2
3
4
Temp.
+
−55 −
3°C
Room temp.
125
+
2°C
−
Room temp.
Time
30±3min.
3min. or less
30±3min.
3min. or less
Capacitance tolerance
Shall be satisfied allowance range.
±20%
Tangent of loss angle
(Df, tan
δ)
Shall be satisfied the voltage on
" Standard list "
Impedance
Shall be satisfied the voltage on
" Standard list "
Resistance to
Soldering heat
Appearance
L.C.
∆C
/ C
Df (tan
δ)
There should be no significant abnormality.
The indications should be clear.
Less than 200% of initial limit
Within
±
20% of initial value
Less than 200% of initial limit
There should be no significant abnormality.
The indications should be clear.
Less than 200%of initial limit
Within
±20%
of initial value
Less than 200%of initial limit
Temperature
cycle
Appearance
L.C.
∆C
/ C
Df (tan
δ)
After the specimens, leave it at room temperature for
over 24h and then measure the sample.
Moisture
resistance
Appearance
L.C.
∆C
/ C
Df (tan
δ)
There should be no significant abnormality.
The indications should be clear.
Less than 200% of initial limit
Within
±20%
of initial value
Less than 200%
of initial limit
As per 4.22 JIS C 5101-1
As per 4.12 JIS C 5101-3
After leaving the sample under such atmospheric
condition that the temperature and humidity are
60±2°C and 90 to 95% RH, respectiveiy, for 500±12h
leave it at room
temperature for over 24h and then measure the
sample.
www.rohm.com
c
○
2009 ROHM Co., Ltd. All rights reserved.
2/5
2009.01 - Rev.D
TCT Series CL Case
Item
Temperature
Stability
Temp.
Data Sheet
Performance
Test conditions (based on JIS C 5101−1 and JIS C 5101− 3)
As per 4.29 JIS C 5101-1
As per 4.13 JIS C 5101-3
−55°C
Within 0/−15% of initial value
Shall be satisfied the voltage on " Standard list "
−
∆C
/ C
Df (tan
δ)
L.C.
Temp.
+85°C
Within
+15/−5%
of initial value
Shall be satisfied the voltage on " Standard list "
5µA or 0.1CV whichever is greater
∆C
/ C
Df (tan
δ)
L.C.
Temp.
+125°C
Within
+20/−5%
of initial value
Shall be satisfied the voltage on " Standard list "
6.3µA or 0.2CV whichever is greater
There should be no significant abnormality.
∆C
/ C
Df (tan
δ)
L.C.
Surge voltage
Appearance
L.C.
∆C
/ C
Df (tan
δ)
Less than 200% of initial limit
Within
±20%
of initial value
Less than 200% of initial limit
As per 4.26JIS C 5101-1
As per 4.14JIS C 5101-3
Apply the specified surge voltage every 5±0.5 min.
for 30±5 s. each time in the atmospheric condition of 85±2°C.
Repeat this procedure 1,000 times.
After the specimens, leave it at room temperature for
over 24h and then measure the sample.
As per 4.23 JIS C 5101-1
As per 4.15 JIS C 5101-3
After applying the rated voltage for 1000+36/0 h without
discontinuation via the serial resistance of 3Ω or less
at a temperature of 85±2°C, leave the sample at room
temperature / humidity for over 24h and measure the value.
As per 4.35 JIS C 5101-1
As per 4.9 JIS C 5101-3
A force is applied to the terminal until it bends to 1mm and
by a prescribed tool maintain the condition for 5s.
(See the figure below)
(Unit : mm)
50
20
F (Apply force)
Loading at
Appearance
High temperature
L.C.
There should be no significant abnormality.
Less than 200% of initial limit
Within
±20%
of initial value
∆C
/ C
Df (tan
δ)
Terminal
strength
Capacitance
Appearance
Less than 200% of initial limit
The measured value should be stable.
There should be no significant abnormality.
R230
1
thickness=1.6mm
45
45
www.rohm.com
c
○
2009 ROHM Co., Ltd. All rights reserved.
3/5
2009.01 - Rev.D
TCT Series CL Case
Item
Adhesiveness
Data Sheet
Performance
Test conditions (JIS C 5101−1 and JIS C 5101− 3)
As per 4.34 JIS C 5101-1
As per 4.8 JIS C 5101-3
Apply force of 5N in the two directions shown in the figure
below for 10±1s after mounting the terminal on a circuit board.
product
The terminal should not come off.
C105
Apply force
YAA
a circuit board
Dimensions
Refer to "External dimensions"
Measure using a caliper of JIS B 7507 Class 2
or higher grade.
Resistance to solvents
The indication should be clear
As per 4.32 JIS C 5101-1
As per 4.18 JIS C 5101-3
Dip in the isopropyl alcohol for 30±5s, at room
temperature.
As per 4.15.2 JIS C 5101-1
As per 4.7 JIS C 5101-3
Dip speed=25±2.5mm
/
s
Pre−treatment(accelerated aging): Leave
the sample on the boiling distilled water for 1 h.
Solder temp. : 245±5°C
Duration
: 3±0.5s
Solder
: M705
Flux
: Rosin 25% IPA 75%
As per 4.17 JIS C 5101-1
Frequency : 10 to 55 to 10Hz/min.
Amplitude : 1.5mm
Time : 2h each in X and Y directions
Mounting : The terminal is soldered on a print circuit board.
Solderability
3/4 or more surface area of the solder coated
terminal dipped in the soldering bath should
be covered with the new solder.
Vibration
Capacitance Measure value should not fluctuate during the
measurement.
Appearance There should be no significant abnormality.
Standard products list, TCT series CL case
Rated
voltage
85°C
(V)
TCT CL 0J 227M
TCT CL 1A 157M
6.3
10
Category
voltage
125°C
(V)
4
6.3
Surge
voltage
85°C
(V)
8
13
Cap.
120Hz
(µF)
Df
Impedance
Leakage
120Hz
100kHz
Tolerance current
(%)
25°C
1WV.60s
(%)
25°C
125°C
−55°C
(Ω)
(µA)
85°C
±
20
±
20
Part No.
220
150
13.9
15
32
30
14
12
20
16
0.8
1.3
=Tolerance (M :
±20%)
Packaging specifications
Case code
CL
A
+
0.1
−
3.5
B
+
0.1
−
6.6
t
1
+
0.05
−
0.3
t
2
+
0.1
−
1.7
Taping [CL case]
1.75±0.1
φ1.5
A
B
+0.1
−0
t
1
5.5±0.1
12.0±0.3
Chip
8.0±0.1
2.0±0.1
4.0±0.1
t
2
Feeding direction
www.rohm.com
c
○
2009 ROHM Co., Ltd. All rights reserved.
4/5
2009.01 - Rev.D
TCT Series CL Case
Packaging style
Case code
CL case
Packaging
Taping
Packaging style
plastic taping
φ180mm
Reel
Symbol Basic ordering units
R
1,000pcs
Data Sheet
Reel [CL case]
+1.0
13
0
15.4
+
1.0
−
φ13
+
0.2
−
Pull direction
Label sticking position
EIAJ ET−7200B compatible
Damp proof package
One reel is packed in aluminum bag.
The size of aluminum bag is 240(a) x 250(b)mm.
The size up to 230(c)mm is to zipper.
A desiccant is packed with a reel.
The aluminum bag is heat-sealed.
The label of the same as the label on the reel is placed on the aluminum bag.
b
c
a
www.rohm.com
c
○
2009 ROHM Co., Ltd. All rights reserved.
0