EEWORLDEEWORLDEEWORLD

Part Number

Search

F.BK.D-.3940.ZG

Description
Single Phase EMI Filter, 250V, 50/60HzHz, METAL PACKAGE
CategoryAnalog mixed-signal IC    filter   
File Size697KB,3 Pages
ManufacturerKEMET
Websitehttp://www.kemet.com
Download Datasheet Parametric Compare View All

F.BK.D-.3940.ZG Overview

Single Phase EMI Filter, 250V, 50/60HzHz, METAL PACKAGE

F.BK.D-.3940.ZG Parametric

Parameter NameAttribute value
MakerKEMET
Reach Compliance Codecompliant
CertificationUL; CSA; VDE
filter typeSINGLE PHASE EMI FILTER
high30 mm
high potential1700 V
Maximum leakage current0.43 mA
length85 mm
Manufacturer's serial numberF.BK
Installation typeCHASSIS MOUNT
working frequency50/60Hz Hz
Maximum operating temperature85 °C
Minimum operating temperature-25 °C
physical sizeL85.0XB52.0XH30.0 (mm)/L3.346XB2.047XH1.181 (inch)
Rated current10 A
Rated voltage250 V
Chassis Mount Filters
Single phase - Multistage
A comprehensive family of multi-stage fliters with general, high and
very high performance characteristics across the frequency spectrum.
Throughout each compact range, the various styles of metal
enclosure offer a choice of termination styles and have medical
options available.
Designed to provide cost effective solutions for a wide range of
applications where space is limited but high performance is required.
F.BK-F.BR-F.BS
series
Current ratings from 1A to 30A
Multi-stage, general, high and very high performance designs
Good low and high frequency performance
Optional termination styles
Medical versions available
Mechanical Specifications
Manufacture:
metal case and cover, internal components sealed
with self-extinguishing resin.
Connections:
faston 6.3 x 0.8 mm (< 16A), flexible leads, screws
M4; ground terminal connected to case.
Electrical Specifications
Rated voltage (V
R
):
max 250V, 50/60Hz
Rated current (I
R
):
Voltage test (2
S
.):
Climatic category:
Case Circ
Diag
C1
C1
C2
G
J
A
A
A
A
A
referred to room temperature = 40°C
line to ground 3000Vdc or 1800Vac
line to line 1700Vdc
HPF (25/085/21);
Temperature range: -25°C to +85°C
Leakage current (I
L
):
at 220V 50Hz, max value
General Performance Multi-stage Filter Range – F.BK
Code
l
R
L
1
L
2
Cx
(µF)
Cy
(pF)
I
L
(mA)
R
(MΩ)
(A) (mH) (mH)
F.BK.D-.3940.ZG 10 2x0.8 2x0.8
F.BK.D-.3660.ZJ
2x0.47 2x4700
2x0.43 0.47
2x0.43 0.47
2x0.43 1
2x0.43 0.22
2x0.91 0.22
F.BK.D-.3940.ZH 12 2x0.58 2x0.58 2x0.47 2x4700
16 2x0.65 2x0.65 2x0.33 2x4700
2x1
2x1
2x4700
2x10000
F.BK.D-.4200.ZK 20 2x0.6 2x0.6
F.BK.D-.4200.ZM 30 2x0.6 2x0.6
Circuit diagram
High Performance Multi-stage Filter Range – F.BR
Code
l
R
L
1
2x22
L
2
2x22
Cx
(µF)
Cy
(pF)
I
L
(mA)
R
(MΩ)
C1
C2
G
H
H
J
Case Circ
Diag
A
A
A
A
A
A
(A) (mH) (mH)
F.BR.D-.3660.ZB 1
F.BR.D-.3940.ZD 3
F.BR.D-.4200.ZF 6
2x9.8 2x9.8
2x7.8 2x7.8
2x0.33 2x4700
2x0.47 2x4700
2x1
2x1
2x1
2x4700
2x4700
2x4700
2x4700
2x0.43 1
2x0.43 0.47
2x0.43 0.22
2x0.43 0.22
2x0.43 0.22
2x0.43 0.22
F.BR.D-.4200.ZG 10 2x4.5 2x4.5
F.BR.D-.4200.ZJ
16 2x2.8 2x2.8
F.BR.D-.4200.ZH 12 2x3.25 2x3.25 2x1
Very High Performance Multi-stage Filter Range – F.BS
Code
l
R
L
1
L
2
Cx
(µF)
Cy
(pF)
I
L
(mA)
R
(MΩ)
C1
C2
G
H
H
J
Case Circ
Diag
B
B
B
B
B
B
(A) (mH) (mH)
F.BS.D-.3660.ZB 1
F.BS.D-.3940.ZD 3
F.BS.D-.4200.ZF
6
2x22 2x0.5
2x7.8 2x0.11
2x0.33 4700
2x1
4700
4700
4700
4700
2x0.43 1
2x0.43 0.47
2x0.43 0.22
2x0.43 0.22
2x0.43 0.22
2x0.43 0.22
2x9.8 2x0.16 2x0.47 4700
F.BS.D-.4200.ZG 10 2x4.5 2x0.06 2x1
F.BS.D-.4200.ZH 12 2x3.25 2x0.05 2x1
F.BS.D-.4200.ZJ
16 2x2.8 2x0.043 2x1
D = Flexible leads
B = Faston 6.3x0.8 mm
I = Screws M4
Approvals
Made in accordance to VDE, UL and CSA requirements
41

F.BK.D-.3940.ZG Related Products

F.BK.D-.3940.ZG F.BK.D-.3660.ZJ F.BK.D-.3940.ZH F.BK.D-.4200.ZK F.BK.D-.4200.ZM
Description Single Phase EMI Filter, 250V, 50/60HzHz, METAL PACKAGE Single Phase EMI Filter, 250V, 50/60HzHz, METAL PACKAGE Single Phase EMI Filter, 250V, 50/60HzHz, METAL PACKAGE Single Phase EMI Filter, 250V, 50/60HzHz, METAL PACKAGE Single Phase EMI Filter, 250V, 50/60HzHz, METAL PACKAGE
Maker KEMET KEMET KEMET KEMET KEMET
Reach Compliance Code compliant compliant compliant compliant compliant
Certification UL; CSA; VDE UL; CSA; VDE UL; CSA; VDE UL; CSA; VDE UL; CSA; VDE
filter type SINGLE PHASE EMI FILTER SINGLE PHASE EMI FILTER SINGLE PHASE EMI FILTER SINGLE PHASE EMI FILTER SINGLE PHASE EMI FILTER
high 30 mm 40 mm 30 mm 45.4 mm 57.6 mm
high potential 1700 V 1700 V 1700 V 1700 V 1700 V
Maximum leakage current 0.43 mA 0.43 mA 0.43 mA 0.43 mA 0.91 mA
length 85 mm 85 mm 85 mm 113.5 mm 119 mm
Manufacturer's serial number F.BK F.BK F.BK F.BK F.BK
Installation type CHASSIS MOUNT CHASSIS MOUNT CHASSIS MOUNT CHASSIS MOUNT CHASSIS MOUNT
working frequency 50/60Hz Hz 50/60Hz Hz 50/60Hz Hz 50/60Hz Hz 50/60Hz Hz
Maximum operating temperature 85 °C 85 °C 85 °C 85 °C 85 °C
Minimum operating temperature -25 °C -25 °C -25 °C -25 °C -25 °C
physical size L85.0XB52.0XH30.0 (mm)/L3.346XB2.047XH1.181 (inch) L85.0XB52.0XH40.0 (mm)/L3.346XB2.047XH1.575 (inch) L85.0XB52.0XH30.0 (mm)/L3.346XB2.047XH1.181 (inch) L113.5XB57.5XH45.4 (mm)/L4.469XB2.264XH1.787 (inch) L119.0XB85.5XH57.6 (mm)/L4.685XB3.366XH2.268 (inch)
Rated current 10 A 16 A 12 A 20 A 30 A
Rated voltage 250 V 250 V 250 V 250 V 250 V
3DH Model
Are there any accelerometer chips with algorithms? Algorithms with step counting and algorithms with sleep status?...
jack1981520 Sensor
What kind of products need a dedicated shutdown discharge circuit?
Recently I saw a development board from NVIDIA with a special discharge circuit, which uses a resistor and a MOS tube connected in series between the power supply and GND. When the power is turned off...
lingking Integrated technical exchanges
[First Round] Interview Questions for Embedded Engineers
I have compiled some frequently asked questions in interviews. I hope these tips will be helpful to you in your interviews. 1. Given an array table, use a macro definition to find the number of elemen...
huaqingyuanjian Programming Basics
How to prevent PCB board from bending and warping during reflow oven
[font="][size=14px]As we all know, PCB boards are prone to bending and warping when passing through the reflow oven. So how to prevent PCB boards from bending and warping when passing through the refl...
jlcgwc PCB Design
Fully automatic high pressure steam sterilization controller
1. Introduction of the WorkThis activity designs a steam sterilizer system, using the IMX1020 evaluation board. The design includes sterilization process control, modbus master module, temperature con...
aple0807 DigiKey Technology Zone
ECG ten electrodes and 12 leads
ECG ten electrodes and 12 leads1. I don't know much about how to obtain electrocardiogram information using ECG. Why is ECG called 12-lead when it only has ten electrodes? What is the relationship bet...
QWE4562009 Test/Measurement

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号