EEWORLDEEWORLDEEWORLD

Part Number

Search

HKA251-73

Description
Toggle Switch, 3PST, On-off, Maintained, Quick Connect Terminal, Toggle Bat Actuator, Panel Mount
CategoryMechanical and electronic products    switch   
File Size61KB,1 Pages
ManufacturerCarling Technologies
Download Datasheet Parametric View All

HKA251-73 Online Shopping

Suppliers Part Number Price MOQ In stock  
HKA251-73 - - View Buy Now

HKA251-73 Overview

Toggle Switch, 3PST, On-off, Maintained, Quick Connect Terminal, Toggle Bat Actuator, Panel Mount

HKA251-73 Parametric

Parameter NameAttribute value
Reach Compliance Codecompliant
ECCN codeEAR99
Actuator length0.687 inch
Actuator typeTOGGLE BAT
body width27.6352 mm
body height20.3962 mm
Body length or diameter33.2232 mm
Nozzle length0.465 inch
Casing type15/32-32
Contact functionON-OFF
Dielectric withstand voltage1000V V
Electrical life50000 Cycle(s)
Insulation resistance100000000 Ω
insulator materialPHENOLIC
Manufacturer's serial numberH
Installation featuresPANEL MOUNT
Maximum operating temperature85 °C
Minimum operating temperature
surface mountNO
Switch actionMAINTAINED
switch function3PST
Switch typeTOGGLE SWITCH
Terminal length0.437 inch
Termination typeQUICK CONNECT
Base Number Matches1
Toggle Switches
H-Series
The H-Series toggle switches are heavy-
duty, high voltage, high amperage, three-
pole switches. These switches have a
slow-make,
slow-break
contact
mechanism, are AC rated to 600V, and
are available in a wide range of ratings,
circuits, terminations and bushing/toggle
configurations.
Specifications
•Certifications*: UL, CSA,
•Dielectric Strength: 1,000 V (minimum)
•Insulation Resistance: 100 Megohms
(minimum)
•Base Material: Phenolic
•Actuator Material: Brass/Nickel Plate
or Polycarbonate
•Bushing Material: Brass/Nickel Plate
* Due to ongoing technological advances, consult factory for
certification specifics.
Dimensional Specifications: in. [mm]
15/32-32UNS-2A
THREAD
.687[17.44]
.465[11.81]
KEYWAY
.072[1.82]
X
.038[.965] DP
.125[3.18] DIA
.075[1.91] DIA
.055[1.40] DIA
.330[8.38]
.187[4.74]
SOLDER LUG
.437[11.09]
.394[10.00]
.250[6.35]
.250 TAB (Q.C.)
.187[4.74]
.187 TAB (Q.C.)
.803[20.40]
3-POLE
#6-32NC-2
THREAD
TERMINAL TYPE
6.000[152.40]
.141[3.58]
.187[4.75]
.350[8.89]
WIRE LEAD
.062[1.57]
.500[12.70] DIA
.500[12.70] DIA
.125[3.17] DIA
WITH LOCKING RING
PRINTED
CIRCUIT
.376[9.55]
.187[4.75]
.422[10.72]
1.308[33.22]
1.088[27.64]
KEYWAY
.072[1.82]
X
.038[.965] DP
NYLON
TOGGLE
IN
4-POLE BASE
1.436[36.47]
.370[9.39]
.465[11.81]
.500[12.70]
.286[7.26]
SCREW
(ASSEMBLED)
.500[12.70] DIA
.687[17.44]
.803[20.40]
1.308[33.22]
.422[10.72]
.038[9.65]
MOUNTING HOLE
WITH KEYWAY
H
SERIES
H
THREE POLE
TOGGLE
K
CIRCUIT
1
K
ON-NONE-OFF
L
ON-NONE-ON
M
ON-OFF-ON
25
1
.187
TAB
(QC)
3
D
R
3
D
3
D
R
-
SCREW
TERM.
4
E
S
4
E
4
E
S
73
WIRE
LEAD
5
F
T
5
F
5
F
T
PC
TERM.
6
G
U
6
G
6
G
U
TERMINATION/FUNCTION
.250
SOLDER TAB
FUNCTION
LUG
(QC)
ON-NONE-OFF
0
1
(ON)-NONE-OFF
A
B
ON-NONE-(OFF)
L
M
ON-NONE-ON
0
1
ON-NONE-(ON)
A
B
ON-OFF-ON
0
1
ON-OFF-(ON)
A
B
(ON)-OFF-(ON)
L
M
RATING
A27
6A 600VAC
12A 250VAC
17A 125VAC
1HP 125VAC
1, 2 OR 3 PHASE
1 1/2HP 250VAC
1, 2 OR 3 PHASE
2HP 480-600VAC;
3 PHASE
25
10A 250VAC
15A 125VAC
3/4HP 125-250VAC
1, 2 OR 3 PHASE
26
3A 250VAC
6A 125VAC
1/4HP 125-250VAC
1, 2 OR 3 PHASE
27
12A 250VAC
17A 125VAC
1 1/2HP 250VAC
1, 2 OR 3 PHASE
28
5A 250VAC
8A 125VAC
1/2HP 125-250VAC
1, 2 OR 3 PHASE
TOGGLE STYLE
2
TOGGLE
LENGTH
.687
1.25
BUSHING
LENGTH
.465
.343
SUFFIX
NO.
73
B2
NEOPRENE
SEAL
78
---
BAT
NOTES:
Shading indicates standard configurations.
For bushing accessories, see pages 69 and 70.
1
Consult factory for additional circuits.
2
Nylon toggles are available with 4-pole base only.
NBL toggle uses black oxide plated metal bushing for standard construction. NWH toggle uses nickel plated
metal bushing for standard construction.
NYLON .687
.687
.465
.465
NBL3
NWH3
NBL8
NWH8
54
Carlingswitch,Inc. (860) 793-9281• Carlingswitch, LTD. Int + 44 1392-364422 • Carlingswitch Asia-Pacific, LTD. Int + 852-2737-2277
How to implement ship mode in Li-ion battery designs
Author: Texas Instruments Gautham Do you remember that many battery-powered electronic toys have a small plastic pull tab on the battery (see Figure 1) that you pull to make the toy start moving? This...
alan000345 TI Technology Forum
Read the good book "The Self-Taught Handbook for Electronic Engineers" - Mastery Edition
When I saw this activity, I was very interested and wanted to read its content. I didn’t apply with high hopes, but I didn’t expect to be selected. I’m really happy.Today, I just received the book sen...
一个小白5 Analog electronics
TI E2E Chinese Community celebrates its 8th anniversary, with 8 technical collections for you who love technology!
TI E2E Chinese Community 8th Anniversary, 8 technical collections for you who love technology! The event has started~Event time: From now until September 15, 2019 Click here to enter the event Activit...
EEWORLD社区 TI Technology Forum
What is the function of the DET signal?
In many interfaces, you can see signals with the suffix DET. 1. I would like to ask what the function of these signals is (I guess it is to check whether there is any device connected)? 2. What is the...
普拉卡图 Industrial Control Electronics
Several issues with the tps65130 chip
[size=4] baidu.php?url =0f0000jeTx0mG_-ZTjIRI5jUHVr15dzJ-bLfvEeuERF9ehwDE14FOLSbLWnfKtZyC_e94PPS6pYv6YH2e7rEus1spa_a0v0POCRcKxjkmJ1 bq_UjDrOySUE0aIwu0eulYutFVg4QSWxoIHjGrBZ-DAeE-Rgj2a3tQz-rAmdYfk1u2ZE...
qwqwqw2088 Analogue and Mixed Signal
B-U585I-IOT02A Bluetooth problem solved
The Bluetooth problem of this development board has troubled me for a long time. Maybe all development boards do not have the STM32WB Bluetooth firmware when they leave the factory, so errors always o...
littleshrimp MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号