EEWORLDEEWORLDEEWORLD

Part Number

Search

U.FL-2LP(V)-04N2T-A-35

Description
Interconnection Device, ROHS COMPLIANT
CategoryThe connector    The connector   
File Size194KB,7 Pages
ManufacturerHirose
Websitehttp://www.hirose-connectors.com/
Environmental Compliance
Download Datasheet Parametric Compare View All

U.FL-2LP(V)-04N2T-A-35 Overview

Interconnection Device, ROHS COMPLIANT

U.FL-2LP(V)-04N2T-A-35 Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
MakerHirose
package instructionROHS COMPLIANT
Reach Compliance Codeunknown
Connector typeINTERCONNECTION DEVICE
Base Number Matches1
The product information in this catalog is for reference only. Please request the Engineering Drawing for the most current and accurate design information.
All non-RoHS products have been discontinued, or will be discontinued soon. Please check the products status on the Hirose website RoHS search at www.hirose-connectors.com, or contact your Hirose sales representative.
Ultra Small Surface Mount Coaxial Connectors - 1.9mm or 2.4mm Mated Height
U.FL Series
Up to 6GHz Transmission Speed
Mated height comparison (with E.FL series)
U.FL-LP-040
U.FL-LP-066
1.9(2.0Max)
2.4(2.5Max)
U.FL-LP(V)-040
E.FL-LP-040
E.FL-LP-066
3(3.2Max)
E.FL
U.FL
sFeatures
1. Nominal mated height of 1.9 or 2.4mm (Max. 2.0 or 2.5mm)
2. Small mounting area
The receptacle occupies an area of 7.7mm
2
.
qSpace
Factor of Mated Connector
Plug
2.5Max
U.FL-LP-040
Cable
3. Light weight
Receptacle: 15.7mg
Dia.0.81
4. Accepts high frequency transmission.
To meet the frequency requirements of a wide variety of
miniature devices, the connectors offer high frequency
performance from DC to 6GHz, with a V.S.W.R. of 1.3 to 1.5
max.
Packaged on tape-and-reel the receptacles can be placed with
vacuum nozzles of the automatic placement equipment.
U.FL-R-SMT-1
Receptacle
Cable
Plug
2.5Max
U.FL-LP-066
Dia.1.32
Dia.1.13
U.FL-R-SMT-1
Receptacle
5. Automatic board placement
6. Plugs are terminated with ultra-fine coaxial
(fluorinated resin insulated) cable
2.0Max
Standard ultra-fine coaxial cable of 0.81mm diameter (single
braid shielding) is used for the plug termination, assuring secure
and stable connections.
Plug
U.FL-LP(V)-040
Cable
Dia.0.81
7. Simple connector mating / unmating
Use of available extraction tool assures correct disconnection
of the plug and receptacle.
U.FL-R-SMT-1
Receptacle
8. Verification of the fully mated condition
2.4Max
Tactile click sensation confirms fully mated condition, assuring
complete electrical and mechanical connection.
Plug
U.FL-LP-062
Cable
Dia.1.00
sApplications
Cellular phones, PHS, mobile phones, wireless communication
devices, electronic measuring instruments, GPS, wireless LAN,
Bluetooth and any application requiring high frequency
transmission using small coaxial connectors.
U.FL-R-SMT-1
Receptacle
Plug
2.4Max
U.FL-LP-088
Cable
Dia.1.37
U.FL-R-SMT-1
Receptacle
2009.2w
1

U.FL-2LP(V)-04N2T-A-35 Related Products

U.FL-2LP(V)-04N2T-A-35 U.FL-LP-068N2T-A-(65)
Description Interconnection Device, ROHS COMPLIANT RF SMA/SSMA Connector, 1 Contact(s), Male, Panel Mount, Solder Lug Terminal, Plug
Is it Rohs certified? conform to conform to
Reach Compliance Code unknown unknown
Base Number Matches 1 1
Problems with frequency modulation using MAX2607
This is a verification board. The error is because the minimum spacing was changed when making a homemade PCB board. Please don't mind. L3 and L4 should be 120nh in theory, but since they were not ava...
VHDLI2C11 RF/Wirelessly
Recruiting BLE software development engineers (with favorable treatment)
[i=s]This post was last edited by Lazy Cat Love Flying on 2019-4-3 11:08[/i] Statement: I am recruiting for a friend: Due to the expansion of the company's business, we are now recruiting several BLE ...
懒猫爱飞 Talking about work
Award-winning lecture: Nexperia Micro Classroom - Explanation of parameters in the power GaN device data sheet
The Anshi Semiconductor micro-classroom will start from 2:30 to 3:00 pm on September 22 (Thursday)!Click here to sign up for lectures and interactions. Not only can you learn knowledge, but you will a...
eric_wang Power technology
[Environmental Expert's Smart Watch] Part 12: Configuration of watch name and time
1. Introduction The watch will definitely use the same firmware when it leaves the factory, so the name must be the same, so each user will modify the name of the watch when they get it. At the same t...
w494143467 onsemi and Avnet IoT Innovation Design Competition
[TI recommended course] #Boost and buck-boost DCDC converters help wireless charging design#
//training.eeworld.com.cn/TI/show/course/5501...
朝哥Carry TI Technology Forum
Why does the servo motor make noise during operation?
[align=left][color=rgb(0, 0, 0)][font=sans-serif] Some users may experience loud noises when using servo motors. Most people may think that this is a quality problem with the servo motors! In fact, th...
森默电气 Industrial Control Electronics

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号