EEWORLDEEWORLDEEWORLD

Part Number

Search

FLCSMC6ABL

Description
Fiber Optic Connector, 62.5/125um, Multi Mode, Simplex, ROHS COMPLIANT
CategoryThe connector    The connector   
File Size201KB,2 Pages
ManufacturerPanduit
Websitehttp://www.panduit.com
Environmental Compliance
Download Datasheet Parametric View All

FLCSMC6ABL Online Shopping

Suppliers Part Number Price MOQ In stock  
FLCSMC6ABL - - View Buy Now

FLCSMC6ABL Overview

Fiber Optic Connector, 62.5/125um, Multi Mode, Simplex, ROHS COMPLIANT

FLCSMC6ABL Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
package instructionROHS COMPLIANT
Reach Compliance Codecompliant
ECCN codeEAR99
Other featuresPANDUIT
Connection TypeSIMPLEX
Connector typeFIBER OPTIC CONNECTOR
Contact to complete cooperationNOT SPECIFIED
Contact materialNOT SPECIFIED
Coupling typeSNAP
DIN complianceNO
Fiber size62.5/125um
IEC complianceNO
Insertion loss0.3 dB
MIL complianceNO
modelMULTI
Installation typeCABLE
OptionsGENERAL PURPOSE
Base Number Matches1
Keyed LC OptiCam
®
Pre-Polished
Fiber Optic Connectors
SPECIFICATION SHEET
specifications
Keyed LC small form factor (SFF) pre-polished connectors
shall exceed TIA/EIA-568-B.3 performance requirements,
and contain a factory-terminated fiber, eliminating field
polishing and adhesive. Keyed LC pre-polished connectors
shall be mechanically keyed with color-specific positive
and negative keying features to prevent unintentional
mating with unlike keyed or non-keyed adapters. Keyed LC
pre-polished connectors shall have an average insertion
loss 0.3dB per mated pair for multimode and singlemode
fiber. Keyed LC pre-polished connectors shall captivate
fiber and buffer in one action allowing for up to two
re-terminations with no degradation in performance.
Keyed LC OptiCam
®
Pre-Polished
Multimode Simplex Connectors
Keyed A (black):
FLCSMC^ABL
Keyed B (red):
FLCSMC^BRD
Keyed C (green):
FLCSMC^CGR
Keyed D (yellow):
FLCSMC^DYL
Keyed E (orange):
FLCSMC^EOR
Keyed F (dark blue):
FLCSMC^FDB
Keyed LC OptiCam
®
Pre-Polished
Singlemode Simplex Connectors
Keyed A (black):
Keyed B (red):
Keyed C (green):
Keyed D (yellow):
Keyed E (orange):
Keyed F (dark blue):
FLCSSCABL
FLCSSCBRD
FLCSSCCGR
FLCSSCDYL
FLCSSCEOR
FLCSSCFDB
technical information
Standards requirements:
Fiber compatibility:
Fiber size and type:
Exceed TIA/EIA-568-B.3 performance requirements
62.5/125µm OM1, 50/125µm OM2, 50/125µm OM3/OM4, 9/125µm OS1/OS2
900µm tight-buffered fiber
250µm coated fiber, by using F250BT-C 250 micron fiber build-up tube
kit or FO6CB or FO12CB fan-out kit
1.6mm – 2.0mm and 3.0mm jacketed cable with optional boots
Zirconia ceramic with a pre-polished fiber stub
0.3dB average (multimode and singlemode)
>20dB (multimode), >26dB (10Gig
multimode), >50dB (singlemode)
OptiCam
®
1.6/2.0mm Boots
Black boots:
FMCBT2BL-X*
OptiCam
®
3.0mm Boots
Black boots:
FMCBT3BL-X*
*X = Bag of 10 Boots; 100 per carton.
Jacketed cable size:
Ferrule type:
Insertion loss:
Return loss:
key features and benefits
Color-specific keys with
positive and negative
keying features
Factory pre-polished
fiber stub endface
Mechanically and visually distinguish connections to prevent unintentional
insertion into unlike keyed or non-keyed ports, allow network design
flexibility and versatility, and accommodate more discrete networks
Eliminates inconsistent and time-consuming field polishing to deliver
required optical performance; reduces termination time (less than half
the time of field polish connectors) and the number of installation
tools required
Secures both the fiber and the buffer during the camming step to
facilitate consistent termination results; reduces the termination time
compared to conventional termination methods
Allows up to two re-terminations to achieve optimum termination results;
reduces the number of rejected connectors and terminations to provide
yield rates approaching 100% for lower installed costs
OptiCam
®
Termination Tooling
OptiCam
®
Termination Kit:
FCAMKIT
OptiCam
®
Conversion
Kit (upgrades
Opti-Crimp
®
Kit to also
terminate OptiCam
®
Connectors):
FPPKIT-CVY
Field polish kit
upgrade (upgrades
field polish kit to also
terminate OptiCam
®
Connectors):
FIELDKITUPG
LC cradles (2 per pkg.):
FLCC
Keyed LC Mini-Com
®
Duplex Adapter
Modules (Ceramic Split Sleeves)
Keyed A (black):
Keyed B (red):
Keyed C (green):
Keyed D (yellow):
Keyed E (orange):
Keyed F (dark blue):
CMDABLLCZ**
CMDBRDLCZ**
CMDCGRLCZ**
CMDDYLLCZ**
CMDEORLCZ**
CMDFDBLCZ**
Dual cam design with fiber
and buffer clamps
Translucent housing
assembly (laser marked)
Non-optical disconnect design
Universal termination tool with
integrated visual termination
indicator (VTI)
Facilitates inspection of the fiber termination quality, resulting in rapid
installations, improved termination yields, and lower installed costs;
laser marked to identify fiber stub fiber type (9µm, 62.5, 50, or 50X)
Maintains data transmission under tensile loads for jacketed cable
Ensures fast, consistent, and optimal terminations of all OptiCam
®
Connectors with connector specific cradles; offers visual indication of
proper termination after the cam step has been completed to virtually
eliminate operator error to deliver a lower installed cost
Keyed LC Opticom
®
Fiber Adapter Panels
(Ceramic Split Sleeves)
Keyed A (black):
FAP‡WABLDLCZ
Keyed B (red):
FAP‡WBRDDLCZ
Keyed C (green):
FAP‡WCGRDLCZ
Keyed D (yellow):
FAP‡WDYLDLCZ
Keyed E (orange):
FAP‡WEORDLCZ
Keyed F (dark blue):
FAP‡WFDBDLCZ
LC Lock-in Duplex Clip
LC lock-in
FLCCLIW-X
duplex clip:
^Substitute for fiber type: 6 = 62.5/125µm OM1,
5 = 50/125µm OM2, X = 10Gig
50/125µm
OM3/OM4 or 9 = 9/125µm OS1/OS2.
**Substitute for module color: AW for Arctic White,
BL for Black, BU for Blue, EI for Electric Ivory, or
IW for Off White.
‡Substitute for number of adapters: 6, 8, or 12.
applications
Secure networks require a level of visual and
mechanical differentiation, and physical layer
security that conventional LC connector solutions
cannot provide. Typical applications for Keyed LC
OptiCam
®
Connectors include maintenance or
emergency restoration of secure fiber networks
and retrofit/initial install of behind the wall (BTW)
connections and the permanent side of interconnect
and cross-connect patch fields. Keyed LC OptiCam
®
Connectors eliminate the need for endface polishing
and adhesive, enabling faster deployment, especially
in remote areas and confined spaces. The hand-held
OptiCam
®
Termination Tool gives installers the
flexibility to terminate in very close proximity to the
application without having to switch tools or find
benchtop space.
w w w. p a n d u i t . c o m
GD32E231 incense machine control board
[i=s]This post was last edited by Xiaotao Electronics on 2019-6-23 15:59[/i]IntroductionThe control board of the incense machine is based on GD32E231 as the main control, and uses timers and PWM to co...
小涛电子 GD32 MCU
SPI interface oled screen driver based on pic18f25k22 microcontroller
void SPI_PORT_INIT(void){TRISBbits.TRISB3=0;//SDO2TRISBbits.TRISB1=0;//SCK2TRISAbits.TRISA6=0;//D/CTRISAbits.TRISA7=0;//RESANSELBbits.ANSB3=0;ANSELBbits.ANSB1=0;}void OLED_SPI_INIT(void){SSP2CON1=0X30...
charles.xiong Microchip MCU
[RVB2601 Creative Application Development] Design of a Farmland Pest Control Device
[i=s] This post was last edited by Mengxi Kaiwu on 2022-5-12 17:09[/i]Design of pest control device for farmland1. Project Background This project is the design of a farmland pest control device. Farm...
梦溪开物 XuanTie RISC-V Activity Zone
[RVB2601 Creative Application Development] 2. Light up the LED
As a low-level engineer, I deal with pipes and pins all day long. So the second plan is to light the lamp. Checked the schematic diagram: The green light is at the PA25 pin. I don't like yellow lights...
ddllxxrr XuanTie RISC-V Activity Zone
Level shifter reverse circuit
Please help me to see how to design the circuit in the figure below...
lhjsol Power technology
Please advise, is it necessary to consider the safety power when calculating the LED resistance?
For example, if the resistance of an LED is 4K, the current is 5mA, and the voltage is 24V, then the resistance power is 0.1W. I usually use 0805, which is 0.125W. What does the safety resistance in t...
sky999 PCB Design

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号