M6000 series
H6000 series
VCXO 5.0V
Full/Half size, Thru-hole, HCMOS/TTL
Features
Frequency range of 1KHz to 150MHz
Industrial temperature range of -40 to +85ºC
Excellent incremental and best-straight-line
linearity
Start-up time is less than 5ms
RoHS Status
Applications
Phase locked loops
xDSL customer premise equipment
3 MHz to 55MHz
Cable modems
ATM/SONET/SDH
Electrical Specifications
Parameter
Frequency
Range
Frequency
Stability
Aging
Operating
Temperature
Supply Voltage
Supply Current
Output Levels
Rise & Fall
Times
Input
Impedance
Symmetry
Control Voltage
Bandwidth
T
Vcc
Icc
“0” Level, sinking 16mA
“1” Level, sourcing 10mA
Symbol
F
∆F/F
Condition
Min
0.001
Typ
Max
150
Unit
MHz
ppm
ppm
ppm/yr
Note
Operating Temperature at 25°C
First Year
After First Year
-40°
4.5
±
40
3
1
±
50
+85°
5.0
30
5.5
45
0.4
4
2
°C
V
mA
V
ns
KOhm
V
DD
-0.4
2.5
15
1000
45/55
15
150
From 0.4 to (V
DD
-.4) V
(Above 35 MHz)
Pin 5., Vc
At V
DD
/2
%
KHz
75 South Street, Hopkinton, MA 01748 • 800-982-5737 • 508-497-6377 • FAX 508-435-5289 • www.valpeyfisher.com • RevA_1007
1
M6000 series
H6000 series
VCXO 5.0V
Full/Half size, Thru-hole, HCMOS/TTL
Environmental and Mechanical Conditions
Parameter
Shock
Vibration
Humidity
Gross Leak
Fine Leak
Pins
Bend Test
Header
Case
Marking
Resistance to Solvents
Center Frequency is between Two Voltages
with ±50 ppm stability
Specification
1000 Gs, 0.35 ms, 1/2 sine wave, 3 shocks in each plane
10-2000 Hz of .06" d.a. or 20 Gs, whichever is less
Resistant to 85° R.H. at 85°C
Each unit checked in 125°C fluorocarbon
Mass spectrometer leak rate less than 2 X 10
-8
atm,
cc/sec of helium
Kovar, nickel plated with 60/40 solder coat
Will withstand two bends of 90° from reference
Steel, with nickel plated
Stainless steel, type 304
Permanent black epoxy ink or laser marked
MIL STD 202, Method 215
DESCRIPTIONS
M6001,
H6001
M6002,
H6002
M6003,
H6003
M6004,
H6004
±175 ppm, min. deviation when using
0.3 to 10V control‐voltage
±75 ppm, min. deviation when using
0.3 to 4.0V control‐voltage
±175 ppm to ±300 ppm deviation when
using
0.3 to 10V control‐voltage
±125 ppm deviation when using
0.3 to 4.0V control‐voltage
±75 ppm to ±300 ppm deviation when
using
1.0 to 4.0 control‐voltage, for use where
the
control voltage is 1 volt off both rails
±150 ppm, min. deviation when using
0 to 5.0 control‐voltage
±125 ppm to ±250 ppm deviation when
using
0.5 to 4.5 control‐voltage
±75 ppm capture when using 0.5 to 4.5V
control‐voltage and 2.5V center with 50
ppm stability
±100 ppm capture when using 0.5 to 4.5V
control‐voltage and 2.5V center with 50
ppm stability
±150 ppm capture when using 0.5 to 4.5V
control‐voltage and 2.5V center with 50
ppm stability
M6005,
H6005
M6006,
H6006
M6007,
H6007
M6021,
H6021
M6022,
H6022
M6023,
H6023
Center Frequency is at 2.5V with ±20 ppm stability
75 South Street, Hopkinton, MA 01748 • 800-982-5737 • 508-497-6377 • FAX 508-435-5289 • www.valpeyfisher.com • RevA_1007
2