• Optional Remote I/O via Flex modules. Communication can be
via the DeviceNet communication platform or the Remote I/O
communication platform.
Available from 23-1200 Amperes.
Specifications
Approvals
C
UL
US
Standards
The ElectroGuard Safety Isolation System is used in place of a
disconnect switch for Lockout and Tagout (LOTO). It uses power
contactors and Remote Lockout Stations to accomplish LOTO.
Isolating the electrical energy usually involves calling an electrician to
turn “Off ” the main disconnecting means. The electrician would
then perform LOTO of the disconnecting means operating handle.
This same procedure is required to perform cleaning, maintenance,
setup, lubrication or adjustment. Machines or processes with
multiple access points may require operator/maintenance
intervention several times a shift (perhaps as often as 60 times per
shift).
To perform these activities, the operator/maintenance person may
be required to place part of his or her body into an area not accessed
during normal operation. This may cause serious or fatal injury if
LOTO procedures are not followed.
The ElectroGuard Safety Isolation System allows the machine
operator to safely and quickly accomplish LOTO with dramatically
reduced downtime.
Provides Energy Isolation
• Power isolation accomplished by means of contactors rather than
disconnect switches.
• Uses redundant, independent and self-monitoring circuits to
detect a system fault.
• Prevents accumulation of faults in order to maintain the integrity
of the safety system.
• Tamper-resistant design.
Convenient Remote Lockout Station
• Allows remote isolation of the electrical power to the machine or
process—machine operator simply turns “Off ” a Remote
Lockout Station.
• A light on the Remote Lockout Station indicates that the three-
phase power source to the machine or process has been isolated.
No Light Means No Entry.
• If a fault occurs in the Safety Isolation System, the “System
Isolated” light on the Remote Lockout Stations will not
illuminate.
• Easy Lockout/Tagout.
Certified by TUV to meet requirements of Category 4
• Certified by TUV to meet Category 4, the most stringent safety
category defined within International Standard EN 954-1/ISO
13849-1.
• Subjected by TUV to rigorous third party testing and verification
of the Failure Mode & Effect Analysis (FMEA).
Estimated Component Life
Remote Lockout Station
Power Contactors
(Isolation & Grounding)
Environmental
Storage Temperature
Operating Temperature
Relative Humidity,
Non condensing
Power Panel Construction
Listed Industrial Control Panel;
TUV Rheinland certified; CE marked
for all applicable directives
IEC/EN 60204-1; IEC/EN 60439-1;
Category 4 to International Standard
EN 954-1/ISO 13849-1; 98/37/EC
Machinery Directive; 89/336/EC EMC
Directive; 73/23/EC Low Voltage
Directive; Fulfils the function of an
energy isolating device in accordance
with the conditions set forth in the
FedOSHA letter of interpretation
pertaining to Section 1910.147(b);
Cal/OSHA 3314.
250,000 operations
23A - 85A: 2,000,000 operations
110A-1200A: 1,000,000 operations
-10°C...+60°C (14°F...140°F)
0°C...+40°C (32°F...104°F) (Ambient)
90% Relative Humidity
Tamper-resistant Control Module
23A-85A systems support up to 4
Remote Lockout Stations without an
Expansion Module
110A-1200A systems support up to 6
Remote Lockout Stations without an
Expansion Module
Control Module with viewing window
for visual check of status indicator lights
Top and bottom 25.4mm (1.0in)
conduit entry (removable plug in
bottom conduit hole)
Sealing provision for tamper-resistance
Operating handle accepts up to 3
padlocks
4 port—supports up to 4 lockout
stations
• allows the systems to
accommodate up to 24 Remote
Lockout Stations
10 port—supports up to 10 lockout
stations
• allows the systems to
accommodate up to 60 Remote
Lockout Stations
Window for viewing status indicator
lights; Sealed for tamper-resistance
Remote Lockout Stations
Safety Mats,
➊
Light Curtains,
➊
E-Stop Stations,
➊
Proximity Switches,
➊
Photo Switches
➊
+10%, -15% of the line voltage
Remote Lockout Station
Construction
Expansion Module
Construction
Safety Isolation Sys. Inputs
Standard Inputs from
Optional Inputs from
Rockwell Automation
Safety Products
System Operational Limits
➊
Use of any of these input devices will not meet Lockout/Tagout (LOTO)
requirements.
12-2
Safety Isolation System
ElectroGuard
Overview
Principle of Operation
Power Circuit
1IC
Incoming
3 Phase
Power
H1
X1
Disconnecting
Means/Branch
Circuit Protection
➊
H2
Trans.
X2
GC
Voltage
Decay
Relays
(VDR)
2IC
To Motor
Controllers
To Loads
After using the normal stopping
method of the machine or process,
the machine operator turns a
Remote Lockout Station handle
from the “On” to “Off ” position.
The station signals the isolation
contactors (1IC and 2IC) to drop
out and isolate the supply voltage
from the loads (see Control
Circuit).
When system residual voltage
decays to pre-determined levels,
the grounding contactor (GC) is
energized, connecting the load to
ground (see Power Circuit). The
grounding contactor (GC) is
electrically and mechanically
interlocked with the isolation
contactors (1IC and 2IC).
The “System Isolated” Light will
now illuminate on the Remote
Lockout Station to indicate the
system is isolated. The machine
operator then Locks-Out and
Tags-Out the station in the “Off ”
position.
Control Power
Grd
Control Circuit
Remote Lockout Station
Off
On
GC
1IC
GC
2IC
VDR
1IC
2IC
GC
Mechanically
Interlocked
1IC, 2IC,
&
GC are
mechanically
and electrically
interlocked
GC
1IC
2IC
System Isolated (*)
(*) = “On” when the Remote
Lockout Station switch is “Off”
➊
Available factory installed within the ElectroGuard as an option.
Optional Features
• Four (4) or ten (10) port Expansion Modules to permit additional Remote
Lockout Stations to be used (see page 12-16 for details).
• Pneumatic Isolation Module to isolate pneumatic energy (see page 12-15 for
details).
• Status communication to a remote PLC (see page 12-17 for details).
• Fusible disconnect switch (Bulletin 2032) or thermal-magnetic circuit breaker
(Bulletin 2033) to provide branch circuit protection.
Optional Pneumatic Isolation Module
12-3
Safety Isolation System
ElectroGuard
Non Combination Systems
+
Power Panel
3-Phase Max. Hp Rating (60Hz)
Ampere
Rating
(AC-3)
23
43
85
110
180
210
300
420
630
860
1200
Type 1 General
Purpose
Enclosure
2031-A0023A⊗
2031-A0043A⊗
2031-A0085A⊗
2031-A0110A⊗
2031-A0180A⊗
2031-A0210A⊗
2031-A0300A⊗
2031-A0420A⊗
2031*-A0630A⊗
2031*-A0860A⊗
2031*-A1200A⊗
One or More Remote Lockout Stations
(conduit hub not included)
Product Selection: For North America (see page 12-19 for Ordering Instructions)
Catalogue Number
➊
Type 12
Dust tight
Enclosure
2031-A0023J⊗
2031-A0043J⊗
2031-A0085J⊗
2031-A0110J⊗
2031-A0180J⊗
2031-A0210J⊗
2031-A0300J⊗
2031-A0420J⊗
2031*-A0630J⊗
2031*-A0860J⊗
2031*-A1200J⊗
200V
5
10
25
40
50
60
100
150
200
250
450
230V
7.5
15
30
40
60
75
125
175
250
300
450
460V
15
30
60
75
150
-
250
350
500
600
900
575V
15
30
60
100
150
200
300
400
600
700
900
Type 12 Motor
Control Centre
Type Enclosure
(with bussing)
2031-!0023J⊗
2031-!0043J⊗
2031-!0085J⊗
2031-!0110J⊗
2031-!0180J⊗
2031-!0210J⊗
2031-!0300J⊗
2031-!0420J⊗
2031-!0630J⊗
2031-!0860J⊗
2031-!1200J⊗
Type 4
Watertight
Painted Steel
Enclosure
2031-A0023F⊗
2031-A0043F⊗
2031-A0085F⊗
2031-A0110F⊗
2031-A0180F⊗
2031-A0210F⊗
2031-A0300F⊗
2031-A0420F⊗
2031*-A0630F⊗
2031*-A0860F⊗
2031*-A1200F⊗
Type 4X
Watertight
Stainless Steel
Enclosure
2031-A0023C⊗
2031-A0043C⊗
2031-A0085C⊗
2031-A0110C⊗
2031-A0180C⊗
2031-A0210C⊗
2031-A0300C⊗
2031-A0420C⊗
2031*-A0630C⊗
2031*-A0860C⊗
2031*-A1200C⊗
To order the Time Delay feature, add the following Catalogue String to the end of the Catalogue Number shown in the
table:
Factory set 30 second time delay feature:
-1TD
Example:
Catalogue Number
2031-A0180A⊗
becomes Catalogue Number
2031-A0180A⊗-1TD
to include the time delay feature.
* Input Power Feed Catalogue Number Code
The Catalogue Number as listed is incomplete. Select an Input Power Feed Code from the table below.
Example:
Catalogue Number
2031*-A0630J⊗
becomes Catalogue Number
2031T-A0630J⊗
for a “Top Feed” input power requirement.
Input Power Feed
Top Feed
Bottom Feed
Catalogue Number Code
T
B
Example:
Catalogue Number
2031-
!
0085J⊗
becomes Catalogue Number
2031-M0085J⊗
for “600A Line Side Incoming Bus and Outgoing Power Cables”
bussing designation.
Type of Bussing
➋
600A Line Side Incoming Bus and Outgoing Power Cables
1200A Line Side Incoming Bus and Outgoing Power Cables
Line Side Incoming Power Cables and 600A Load Side Outgoing Bus
Line Side Incoming Power Cables and 1200A Load Side Outgoing Bus
⊗
Input Line Voltage Code
Catalogue Number Code
M
S
F
B
!
Bussing Designation
The Catalogue Number as listed is incomplete. Select a Bussing Designation Code from the table below.
The Catalogue Number as listed is incomplete. Select an Input Line Voltage Code from the table below.
Example:
Catalogue Number
2031-A0085J⊗
becomes Catalogue Number
2031-A0085JB
for a 480V 60Hz Input Line Voltage application.
Input Line Voltage
Voltage Code for Catalogue Number
208V 60Hz
H
240V 60Hz
A
480V 60Hz
B
600V 60Hz
C
➊
Optional Time Delay Feature. The Safety Isolation System may be ordered with a factory set time delay feature (30 seconds) in order to allow time for the machine
operator to shut-down drives or other equipment that requires a controlled stop, after the operating handle on a Remote Lockout Station has been moved to the “Off”
position. Consult your local Rockwell Automation sales office for other time settings.
➋
Bus Type: Copper with tin plating. Consult factory for other types of bussing.
12-4
Safety Isolation System
ElectroGuard
Non Combination Systems
Product Selection: Remote Lockout Station
➊
“System Isolated”
Light Colour
White
Type 1 General
Purpose Enclosure
2030-RLSAW
Catalogue Number
Type 12 Dust tight
Type 4 Watertight Painted
Enclosure
Steel Enclosure
2030-RLSJW
2030-RLSFW
Type 4X Watertight Stainless
Steel Enclosure
2030-RLSCW
Product Selection: For Outside of North America (see page 12-19 for Ordering Instructions)
3-Phase Max. kW Rating (50Hz)
Ampere
Rating
(AC-3)
23
43
85
110
180
210
300
420
630
860
1200
230V
7.5
13
25
32
55
63
90
132
200
250
391
400V
11
22
45
55
90
110
160
220
355
500
710
500V
11
22
45
63
110
150
200
300
450
560
888
600V
11
22
45
100
160
200
300
425
500
600
1043
IP 30 Enclosure
2031-C0023P⊗
2031-C0043P⊗
2031-C0085P⊗
2031-C0110P⊗
2031-C0180P⊗
2031-C0210P⊗
2031-C0300P⊗
2031-C0420P⊗
2031*-C0630P⊗
2031*-C0860P⊗
2031*-C1200P⊗
Catalogue Number
➋
IP 54 Motor Control
Centre Type Enclosure
IP 54 Enclosure
(w/bussing)
2031-C0023H⊗
2031-C0043H⊗
2031-C0085H⊗
2031-C0110H⊗
2031-C0180H⊗
2031-C0210H⊗
2031-C0300H⊗
2031-C0420H⊗
2031*-C0630H⊗
2031*-C0860H⊗
2031*-C1200H⊗
2031-!0023H⊗
2031-!0043H⊗
2031-!0085H⊗
2031-!0110H⊗
2031-!0180H⊗
2031-!0210H⊗
2031-!0300H⊗
2031-!0420H⊗
2031-!0630H⊗
2031-!0860H⊗
2031-!1200H⊗
IP 65 Enclosure
2031-C0023W⊗
2031-C0043W⊗
2031-C0085W⊗
2031-C0110W⊗
2031-C0180W⊗
2031-C0210W⊗
2031-C0300W⊗
2031-C0420W⊗
2031*-C0630W⊗
2031*-C0860W⊗
2031*-C1200W⊗
To order the Time Delay feature, add the following Cat. String to the end of the Cat. No. shown in the table:
Factory set 30 second time delay feature:
-1TD
Example:
Catalogue Number
2031-C0180H⊗becomes
Catalogue Number
2031-C0180H⊗-1TD
to include the time delay feature.
* Input Power Feed Catalogue Number Code
The Catalogue Number as listed is incomplete. Select an Input Power Feed Code from the table below.
Example:
Catalogue Number
2031*-C0630H⊗
becomes Catalogue Number
2031T-C0630H⊗
for a “Top Feed” input power requirement.
Input Power Feed
Catalogue Number Code
Top Feed
T
Bottom Feed
B
Example:
Catalogue Number
2031-
!
0085H⊗
becomes Catalogue Number
2031-E0085H⊗
for “600A Line Side Incoming Bus and Outgoing Power Cables”
bussing designation.
Type of Bussing
➌
600A Line Side Incoming Bus and Outgoing Power Cables
1200A Line Side Incoming Bus and Outgoing Power Cables
Line Side Incoming Power Cables and 600A Load Side Outgoing Bus
Line Side Incoming Power Cables and 1200A Load Side Outgoing Bus
⊗
Input Line Voltage Code
Catalogue Number Code
E
D
H
R
!
Bussing Designation
The Catalogue Number as listed is incomplete. Select a Bussing Designation Code from the table.
The Catalogue Number as listed is incomplete. Select an Input Line Voltage Code from the table below.
Example:
Catalogue Number
2031-C0085P⊗
becomes Catalogue Number
2031-C0085PN
for a 380V 50Hz Input Line Voltage application.
Input Line Voltage
220V 50HZ
380-400V 50Hz
400-415V 50Hz
440V 50Hz 500V 50Hz
Voltage Code for Catalogue Number
A
N
G
B
M
550V 50Hz
C
Product Selection: Remote Lockout Station
➊
“System Isolated” Light Colour
Green
IP 30 Enclosure
2030-RLSPG
Catalogue Number
IP 54 Enclosure
2030-RLSHG
IP 65 Enclosure
2030-RLSWG
➊
Safety Isolation Systems rated up through 85A can support a maximum of four (4) Remote Lockout Stations (RLS).
Systems rated from 110A - 1200A can support a maximum of six (6) RLS. If additional RLS are required, order the optional Expansion Module(s) (see page 12-16).
➋
Optional Time Delay Feature. The Safety Isolation System may be ordered with a factory set time delay feature (30 seconds) in order to allow time for the machine
operator to shut-down drives or other equipment that requires a controlled stop, after the operating handle on a Remote Lockout Station has been moved to the “Off”
position. Consult your local Rockwell Automation sales office for other time settings.
➌
Bus Type: Copper with tin plating. Consult factory for other types of bussing.
[i=s]This post was last edited by Jacktang on 2019-8-10 17:04[/i]Many products are now “at your fingertips” through the Internet of Things (IoT) environment, including test equipment such as digital m...
1. Serial port data transparent transmission (already realized)2. Key pairing by pressing keys3. Low power consumption, interrupted by pressing keys (required to be around 20uA)Development cost 5000-1...
This issue recommends e-books from ADI Think TankPractical Handbook of RF and Microwave TechnologyAnalog Devices has been deeply involved in the RF and microwave fields for many years and has the indu...
From: https://mcuoneclipse.com/2019/11/24/wor ... xp-lpc845/After completing a clock using stepper motors (see " DIY Stepper Motor Clock Using NXP LPC845-BRK "), I wanted to build a special clock that...
[color=#000][font=汉仪中黑简, Fujitsu-san, "][size=14px]Getting accurate DC measurements is a common requirement for many applications, but simply purchasing an instrument with high accuracy and sensitivit...
[i=s]This post was last edited by Aguilera on 2019-7-20 17:16[/i]What is PSRR?
PSRR (Power supply rejection ratio), also known as power supply rejection ratio, is an important parameter to measure the...
According to the Russian Satellite News Agency, the Russian Sistemma company recently launched a Russian artificial intelligence program named SistemmaGPT, whose functions are similar to ChatGPT. T...[Details]
The non-contact displacement sensor is a revolutionary improvement on the displacement sensor based on potential technology. Compared with the complex applications in the past, the displacement sensor...[Details]
AsiaInfo Electronics officially launched the first EtherCAT slave dedicated communication SoC solution in Greater China – the AX58200 2/3-port EtherCAT slave dedicated communication SoC with two buil...[Details]
Zuosi Auto R&D released the "2023 Automotive HUD Industry Research Report". The vehicle head-up display system (Head Up Display, or HUD), also called the head-up display system, uses optical princi...[Details]
As mentioned in the previous article, when using peripheral functions, they must be carefully initialized in advance before using their functions. The following is a program listing for system timer ...[Details]
If the development of the integrated circuit industry is sorted out vertically and horizontally, then in the vertical direction, the evolution of process nodes represented by Moore's Law will be a re...[Details]
With the continuous advancement of science and technology, the technical requirements for machine tool products are increasing day by day. In the implementation of the JB/T3382.2-2000 standard, it is...[Details]
step: (Take square wave as an example) 1. Assume that the time corresponding to the required duty cycle A is C=BXA (B is the period of the required signal). Set the positive pulse on the signal g...[Details]
Mr. Zhu Yiming, Chairman and CEO of Changxin Storage, delivered a keynote speech entitled "China's Storage Technology Development and Solutions" at the GSA MEMORY+ Summit held in Shanghai. According ...[Details]
Today at the 2020 Lenovo Innovation Technology Conference, Lenovo showcased the Savior Gaming Phone Pro Transparent Edition. As shown in the picture, the Savior Gaming Phone Pro Transparent ...[Details]
China Energy Storage Network News:
On January 7, the results of the State Grid Corporation's 2021 Science and Technology Award were announced. State Grid Jibei Power's major cultivation ach...[Details]
In recent years, digital television technology has developed rapidly. Digital video mixers can mix two or more digital video signals into one or more digital video signals according to certain algo...[Details]
"Power Supply (PSU)" is actually the abbreviation of "Power Supply Unit". The often mentioned "PC power supply" is actually also an abbreviation. Strictly speaking, "PC power supply" should be call...[Details]
A few months after the rumors, Nintendo did release a cheaper version of the Switch console, which is very straightforwardly called the Switch Lite. According to the president of Nintendo of A...[Details]
The closed-loop servo control system is an automatic control system with high precision, high response speed and high stability, which is widely used in industrial automation, robotics, aerospace, ...[Details]