For information regarding selection of the proper heat sink for your application, refer to "Heat Sink Size Vs. Load Current" graph on page 54 or "Load Current Vs.
Ambient Temperature Characteristics" on page 55.
52
Bulletin 700-SH
Solid-State Relays
Specifications
Control/Input Ratings
Cat. No.
Rated Control
Voltage
Operating Control
Voltage Range
Impedance
➊
Control Voltage Levels
Pick-up Voltage
5...24V DC
700-SH_ _G…
100...120V AC
200...240V AC
700-SH_ _ H…
5...24V DC
75...132V AC
150…264V AC
4…32V DC
36 kΩ +/-20%
72 kΩ +/-20%
5 mA max.
➋
Load/Output Ratings
Cat. No.
Rated Load
Voltage
—
700-SH05G…
24…240V AC
700-SH10G…
700-SH10H…
700-SH25G…
700-SH25H…
700-SH40G…
700-SH40H…
200…480V AC
24…240V AC
200…480V AC
24…240V AC
200…480V AC
180…528 VAC
19…264V AC
180…528V AC
19…264V AC
180…528V AC
19 …264V AC
0.1 A
0.2 A
0.1 A
0.2 A
0.1 A
0.2 A
10 A
10 A
25 A
25 A
40 A
40 A
0.1 A
0.2 A
0.1 A
0.2 A
0.1 A
0.2 A
4A
4A
4A
4A
6A
6A
150 A (@50/60 Hz, 1
cycle)
Load Voltage
Range
—
Applicable Load
Continuous Load
With Heat Sink (A)
➍
Min.
0.1 A
Max.
5A
Current (Resistive)
Without Heat Sink (A)
➍
Min.
0.1 A
Max.
3A
60 A (@50/60 Hz, 1 cycle)
Max. Inrush Current➎
75V AC max.
➌
150V AC max.
➌
4V DC max.
20V AC min.
➌
40V AC min.
➌
1V DC min.
4...32V DC
15 mA max
➋
4V DC max.
1V DC min.
Drop-out Voltage
220 A (@ 50/60 Hz, 1
cycle)
440 A (@ 50/60 Hz, 1
cycle)
The input impedance is measured at the maximum value of the rated supply voltage.
With a constant current input system, SSR impedance varies with a change in input voltage.
Refer to graphs, “Temperature Characteristics…” and “Must Release Voltage” on page 54 for further details.
When specified heat sink is used. Refer to accessories, page 52 for applicable heat sinks. For more details, refer to graphs “Load Current Vs. Ambient Temperature
Characteristics” on page 55, and the “Heat Sink vs. Load Current” graph on page 54.
➎
If the SSR operation is continuous ON/OFF, this value should be reduced by 50%. Refer to “Inrush Current Resistivity” graphs on page 54 for more details.
➊
➋
➌
➍
53
Bulletin 700-SH
Solid-State Relays
Specifications, Continued
Characteristics
Cat. No.
Load Switching Method/
Device
Pick-up Time
Drop-out Time
Output ON Voltage Drop
Output Leakage Current
Output
V
DRM
, V
CEO
(V)
Output di/dt (A/uS)
Output dv/dt (V/uS)
Output
I
2
t (A
2
S)
Output Tj °C Max.
Insulation Resistance
Dielectric Strength
Vibration Resistance (max.)
Shock Resistance (max.)
Ambient Temperature
Storage: -30°C…100°C (-22°F…212°F)
with no icing or condensation
Ambient Humidity
Standards
➊
Weight
Approx. 60g
Operating: 45%…85% (no condensation)
UL508, CSA C22.2, CE, TÜV
Approx. 70g
Approx. 80g
600
-SHO5G = 100,
-SHO10G, -SH25G= 50
-SHO5G = 200,
-SHO10G, -SH25G= 100
-SHO5G = 24.5,
-SHO10G=112.5 -SH25G= 260
700-SH05G, -SH10G, SH25G
Triac
1/2 of load power source + 1 ms max. (DC input)
3/2 of load power source + 1 ms max. (AC input)
1/2 of load power source + 1 ms max. (DC input)
3/2 of load power source + 1 ms max. (AC input)
1.6 V (RMS) max
5 mA max (at 100V AC)
10 mA max (at 200V AC)
600
50
100
1260
125
100 MΩ min (at 500 VDC)
2,500V AC, 50/60 Hz for 1 minute
10…55 Hz, 1.5 mm double amplitude (10 G)
1,000 m/s
2
(100 G)
Operating: -30°C…80°C (-22°F…176°F)
with no icing or condensation
1.8 V (RMS) max
10 mA max. (@ 200V AC)
20 mA max. (@ 400V AC)
1200
100
300
260, SH40 = 1800
700-SH40G
700-SH10H, -SH25H, SH40H
Thyristor
➊
Cat. No. 700-SH_ _ _HZ25 not CE or TÜV approved.
Inrush Current Resistivity
➋
➌
➋
Inrush current resistivity is the ability of an SSR to withstand a large surge current for a short period of time. Surges are considered non-repetitive (max. repeatability
once every 2…5 seconds). Keep the inrush current to half the rated value if it occurs repetitively. Exceeding the non-repetitive inrush current will damage the SSR.
➌
The heat sink size refers to the combined area of the sides of the heat sink that radiate heat. For example, when a current of 18 A is allowed to flow through the SSR
at 40°C, the graph shows that the heat sink size is about 450 cm
2
. Therefore, if the heat sink is square, one side of the heat sink must be 15 cm (15
2
x 2 = 450) or longer.
54
Bulletin 700-SH
Solid-State Relays
Specifications, Continued
Load Current vs. Ambient Temperature Characteristics
➊➋
➊
For the above 5 graphs, the line “with iron plate measuring 100 x 100 x 0.8” means the SSR is mounted directly to an iron plate of at least this size.
➋
All graphs assume conductive grease is being used. Refer to page 56 for details of using conductive grease.