EEWORLDEEWORLDEEWORLD

Part Number

Search

RP300-100-100-S

Description
Three Phase EMI Filter
CategoryAnalog mixed-signal IC    filter   
File Size2MB,3 Pages
ManufacturerAstrodyne TDI
Environmental Compliance
Download Datasheet Parametric Compare View All

RP300-100-100-S Overview

Three Phase EMI Filter

RP300-100-100-S Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
MakerAstrodyne TDI
Reach Compliance Codecompliant
filter typeTHREE PHASE EMI FILTER
Manufacturer's serial numberRP300
Base Number Matches1
RP
RP300 Series
RP300
3PHASE DELTA TO 500A
ROHS COMPLIANT
RADIUS POWER
Your Power Partner
3-Phase Delta Single Stage Power Line Filter
SPECIFICATIONS
Operating Freq.
Usable Freq.
Max. Operating Voltage
Ambient Temperature
Climatic Category
Hipot Rating (L-G)
Terminals (-T)
:
:
:
:
:
:
:
50/60Hz
DC - 400Hz
480V +10%
-25 to 50C
25/100/21
3500VDC
S: 25/50/55A (M5)
65/100A (M6)
150/200A (M10)
300A (M12)
500A (Dual M12)
cURus, EN60939
LEAKAGE CURRENT
Y-cap, nF
0
10
100
1000
2000
mA,
480V/60Hz
0
0.1
1
10
20
Safety Approvals
:
PART NUMBER/ ORDERING
RP300
-X
(Amps)
25
50
55
65
100
150
200
300
500
-Y
(Ycap, nF)
0
10
100
1000
2000
-T
S
Weight
LBS (KG)
Typ.
4.6 (2.1)
5.8 (2.6)
5.8 (2.6)
6.5 (3.0)
11.0 (5.0)
14.4 (6.7)
17.8 (8.1)
19.7 (8.9)
24.0 (10.9)
SCHEMATIC
Note:
Use any combination of -Y with any -X (Amps) rating
e.g. RP300-500-2000-S (500 Amps with 2000nF Ycap)
Optional Ycap on Line side
(consult factory)
www.radiuspower.com
Reference purposes only.
Specifications are subject to change.
Consult factory to verify specifications.
Engineering Assistance: engg@radiuspower.com
Sales:sales@radiuspower.com
51

RP300-100-100-S Related Products

RP300-100-100-S RP300-25-1000-S RP300-25-100-S RP300-100-2000-S RP300-100-10-S RP300-100-0-S RP300-100-1000-S RP300-300-1000-S RP300-300-100-S
Description Three Phase EMI Filter Three Phase EMI Filter Three Phase EMI Filter Three Phase EMI Filter Three Phase EMI Filter Three Phase EMI Filter Three Phase EMI Filter Three Phase EMI Filter Three Phase EMI Filter
Is it Rohs certified? conform to conform to conform to conform to conform to conform to conform to conform to conform to
Maker Astrodyne TDI Astrodyne TDI Astrodyne TDI Astrodyne TDI Astrodyne TDI Astrodyne TDI Astrodyne TDI Astrodyne TDI Astrodyne TDI
Reach Compliance Code compliant compliant compliant compliant compliant compliant compliant compliant compliant
filter type THREE PHASE EMI FILTER THREE PHASE EMI FILTER THREE PHASE EMI FILTER THREE PHASE EMI FILTER THREE PHASE EMI FILTER THREE PHASE EMI FILTER THREE PHASE EMI FILTER THREE PHASE EMI FILTER THREE PHASE EMI FILTER
Manufacturer's serial number RP300 RP300 RP300 RP300 RP300 RP300 RP300 RP300 RP300
Base Number Matches 1 1 1 1 1 1 1 1 1
High-speed circuit design and simulation analysis: Cadence example design details
Circuit design, especially modern high-speed circuit system design, is a job that changes with each passing day as electronic technology develops. It is very interesting and challenging. The purpose o...
arui1999 Download Centre
I would like to ask a question about ultrasonic binary gas concentration measurement?
Has anyone in the forum done research on ultrasonic binary gas concentration measurement? For example, measuring oxygen concentration in air-oxygen mixed gas. I see such sensors on the Internet, but m...
qzc飘曳 Sensor
Is it "reasonable..." to fly a kite made of your own photo?
Original post link: http://mc.dfrobot.com.cn/thread-275083-1-1.html http://mc.dfrobot.com.cn/thread-275083-1-1.html Not long ago, I found a Japanese guy named ARuFa who lives in people's hearts. Out o...
kikiwu DIY/Open Source Hardware
Why is the application of gallium nitride in RF electronics still so popular?
最近,QORVO又推了一篇氮化镓在射频电子中的应用,在这篇中指出,GaN 非常适合提供毫米波领域所需的高频率和宽带宽。它可以满足性能和小尺寸要求,如下图所示。使用毫米波频段的应用需要高度定向的波束形成技术(波束形成将无线电信号聚焦成强指向性的波束,从而提高功率并最大限度地减少用户设备上的干扰)。这意味着 RF 子系统将需要大量有源元件来驱动相对紧凑的孔径。GaN 非常适合这些应用,因为以小封装尺寸...
alan000345 RF/Wirelessly
When the MOS is turned on like 2301, is the VDS voltage 0? That is, there is no loss? The simulation shows that there is no loss.
When the MOS is turned on like 2301, is the VDS voltage 0? That is, there is no loss? The simulation shows that there is no loss....
QWE4562009 Integrated technical exchanges
Battery Management System BMS Technical Data Transfer
1:[/size][/font][/color][/b][color=rgb(51, 51, 1: [/size][/font][/color][/b][color=rgb(51, 51, 51)][font=Microsoft YaHei][size=10.5pt][font=Microsoft YaHei]2: [/size][/font][/color][/b][color=rgb(51, ...
q2512262471 Automotive Electronics

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号