The 1782 laser component is characterized for use as a CW optical source in
CATV and DWDM networks. The 1782 is dc-coupled with a built-in TEC,
thermistor, and monitor photodiode. The device is mounted in a 14-pin, OC-48
pinout compatible butterfly package with the optical isolator mounted on the TEC.
The 1782 incorporates a high efficiency coupling scheme to deliver 40 mW, 50
mW, 63 mW and 100 mW of CW optical power.
Applications
DWDM
CATV
Free Space Optics
Performance Highlights
Parameter
Operating Case Temperature
Wavelength
40
50
63
100
-
-
-
Standard
Enhanced
SMSR
Polarization Extiction Ratio (PMF pigtail)
Optical Isolation
Optical Return Loss
-
-
30
17
32
40
Min
-20
Typ
25
See Page 4
-
-
-
-
-
-
-
-
-
-
-
-
-
Max
+65
Units
C
nm
Optical Output Power
Features
40, 50, 63 & 100 mW Optical Output
Power
OC-48 Pinout Compatible
Telcordia Technologies™ GR-468
Compliant
PM Fiber
-20°C to +65°C Operating Temperature
Range
Monitor Photodiode
RoHS
Threshold Current
Operating Current
RIN
RIN Through 65 km Fiber
-
-
-
-
40
650
-163
-155
-157
-
-
-
-
mW
mA
mA
dB/Hz
dB/Hz
dB/Hz
dB
dB
dB
dB
| REV 2013.07
Information contained herein is deemed reliable and accurate as of the issue date. EMCORE reserves the right to change the design or specification at any time without notice.
1782 DWDM High Power CW Source Laser
DATASHEET | JULY 2013
FIBER OPTICS
Absolute Maximum Ratings
Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute stress
ratings only. Functional operation of the device is not implied at these or any other conditions in excess of those given in the
operational sections of the data sheet. Exposure to absolute maximum ratings for extended periods can adversely affect
device reliability.
Parameter
Operating Case Temperature
Storage Temperature
Laser Forward dc Current
Photodiode Reverse Voltage
Laser Reverse Voltage
TEC current
ESD
Symbol
T
OP
T
STG
-
V
R,MPD
-
I
TEC
-
Condition
continuous
continuous
continuous
continuous
continuous
continuous
HBM: R = 1500
,
C = 100 pF
Min
-20
-40
-
-
-
-
-500
Max
+65
+85
750
10
2
1.7
500
Units
C
C
mA
V
V
A
V
Electrical/Optical Characteristics
Parameter
Operating Case Temperature
Optical Output Power
Threshold Current
Operating Current
Operating Laser Temperature
Laser Bias Forward Voltage
Wavelength
Spectral Linewidth
Optical Isolation
Optical Return Loss
Sidemode Suppression Ratio
Polarization Extinction Ratio
Wavelength Drift Over T
C
Range
Relative Intensity Noise
Monitor PD Current
Monitor PD Dark Current
Thermistor Resistance
Thermistor Temp. Coefficients
TEC Current
TEC Voltage
(1)
1
Symbol
T
op
P
O
I
TH
I
OP
-
V
OP
OP
ISO
ORL
SMSR
PER
TOP
RIN
I
MPD
I
D
R
TH
TC
TH
I
TEC
V
TEC
Condition
-
40 mW version, T = T
set
, I
F
= I
OP
50 mW version, T = T
set
, I
F
= I
OP
63 mW version, T = T
set
, I
F
= I
OP
100 mW version, T = T
set
, I
F
= I
OP
BOL
BOL
Min
-20
40
50
63
100
-
-
18
Typ
25
-
-
-
-
-
-
-
See Page 4
-
-
-
-
-
-
-
-
-
10.0
-4.4
-
-
Max
65
-
-
-
40
650
35
2.7
1.0
-
-
-
-
40
-163
2500
0.2
10.5
-
+1.5
+3.0
Unit
C
mW
mA
mA
°C
V
nm
MHz
dB
dB
dB
dB
pm
dB/Hz
A
A
K
%/C
A
V
BOL, I
F
= I
OP
T = T
set
, I
F
= I
OP
T = T
set
, I
F
= I
OP
, FWHM
-
-
-
I
F
= I
OP
T = T
OP
-
I
F
= I
OP
, V
MPD
= -5 V
I
OP
= 0 mA , V
MPD
= -5 V
T
OP
= 25
C
T
OP
= 25
C
-20C < T
C
< +65C
-20C < T
C
< +65C
-
-
32
40
30
17
-
-
100
-
9.5
-
-1.0
-2.0
1. Linewidth () is calculated using this formula:
=
RIN(f){16(D2L/c)2f2}-1
Where: D = fiber dispersion; L = fiber length (65km); C = velocity of light in free space (3.00E+8);
= opt center wavelength
RIN(f)
= RIN
through fiber (RIN
65km
– RIN
0km
); f = the measurement frequency (860MHz)
| REV 2013.07
Information contained herein is deemed reliable and accurate as of the issue date. EMCORE reserves the right to change the design or specification at any time without notice.
1782 DWDM High Power CW Source Laser
DATASHEET | JULY 2013
FIBER OPTICS
Outline Drawing
Pin Assignments
Pin
1
2
3
4
5
6
7
8
9
10
11
12
13
14
Description
Thermistor
Thermistor
Dc Laser Bias (-)
MPD Anode (-)
MPD Cathode (+)
Thermal Electric Cooler (+)
Thermal Electric Cooler (-)
Case Ground
Case Ground
NC
Laser Common (+), Case Ground
Laser Modulation (-)
Laser Common (+)
NC
| REV 2013.07
Information contained herein is deemed reliable and accurate as of the issue date. EMCORE reserves the right to change the design or specification at any time without notice.
1782 DWDM High Power CW Source Laser
DATASHEET | JULY 2013
FIBER OPTICS
ITU Grid Channel Numbering
Please contact EMCORE Sales for ITU Wavelength Channel availability.
Package Schematic
OPT OUT
1
10K
ISO
NC
14
2
13
GND
DC BIAS
3
0.1uF
choke
(-)
12
RF INPUT
4
(+)
11
(+)
GND
5
(-)
6
(+)
7
(-)
TEC
CASE
GND
10
NC
9
8
| REV 2013.07
Information contained herein is deemed reliable and accurate as of the issue date. EMCORE reserves the right to change the design or specification at any time without notice.
1782 DWDM High Power CW Source Laser
DATASHEET | JULY 2013
FIBER OPTICS
Laser Safety
This product complies with 21 CFR 1040.10 and 1040.11 except for deviations pursuant to Laser Notice No. 50, dated June
24, 2007.
All Versions of this laser are Class 1M laser product, tested according to IEC 60825-1:2007/EN 60825-1:2007
Single-mode fiber pigtail with FC/APC connectors (standard).
Wavelength = 1.5
m.
Maximum power = 100 mW.
Because of size constraints, laser safety labeling (including an FDA class 1M label) is not affixed to the module, but
attached to the outside of the shipping carton.
Product is not shipped with power supply.
Caution: Use of controls, adjustments and procedures other than those specified herein may result in hazardous
laser radiation exposure.
| REV 2013.07
Information contained herein is deemed reliable and accurate as of the issue date. EMCORE reserves the right to change the design or specification at any time without notice.
/*Program description: Use timer TA to generate a fixed-cycle square wave, and control the high-level time of the square wave to controlthe average output power. This control method is called PWM modu...
QT is a very good cross-platform tool. So we only need to master the method of QT to make the interface, and we can easily make QT cross-platform applications.Why should we learn QT_For_Android?1. Exp...
If you have just started to learn microcontrollers, will you feel happy when you use the program to light up the LED or the digital tube? This is a good thing, and it is also the motivation to continu...
This article explains in detail the configuration steps of the KingView Modbus communication usage tutorial Modbus-rtu and Modbus-tcp Modicon communication. See the attached download:...
Understand the hardware system and environment establishmentUnboxingDuring transportation, it may have been subjected to external forces, so it is a little bent, but it does not affect the overall sit...