Ferrocode
Specifications (continued)
Utilization Category (AC)
4A/250V AC/1000VA at COSϕ=1
Max Switched DC Current/Volt 2A/30V DC/60W
Min Switched DC Current/Volt 10mA/10V
Max Output Fuse
Indication
Max Drop Out Time
Impulse withstand Voltage
Operating Temperature
Contamination Level
Humidity
5A quick acting
Green = Power ON
Green = Output closed
<50mS
2500V
-10°C to +55°C (14°F to 131°F)
3
90% RH
IP40 DIN 0470
IP20 DIN 0470
1 x 2.5mm
2
(14 AWG) stranded with
sleeve stripped 8mm,1 x 4mm
2
(14AWG) solid conductor
Plus-minus terminal screws M3.5
Box terminal with wire protection
314g (0.69lbs)
530g (1.17lbs)
Red polycarbonate
16 way D = 120 H = 73 W = 45.5
C in accordance with VDE 0110
35mm DIN rail
24V DC +/– 15%
<1VA
1A output fuse
ON = 7mm, OFF = 9mm
ON = 9mm, OFF = 14mm
1 N.O. & 1 N.C.
0.5A/120V AC/60VA at COSϕ =1
Description
A two-channel system, the Ferrocode setup consists of an actuator
and a separate safety switch head that is connected to a monitoring
control unit. The Ferrocode uses electromagnetic coding, which
provides a higher level of security over magnetic coding systems. To
further prevent possible override of the system, both sensor and
actuator are supplied with tamper-resistant mounting hardware.
The absence of moving parts and direct physical contact between
sensor and actuator eliminate mechanical wear.
A Ferrocode sensor may be used without the control unit for low
power/low risk applications. However, risks should be thoroughly
evaluated prior to application of this method.
The control unit should be used when monitoring and checking of
the circuit is required. Up to 6 Ferrocode switches can be interfaced
with the 110/230V control unit and up to 15 Ferrocode switches
with the 24V version. A control unit may also be used in conjunction
with electromechanical safety devices such as limit switches, gate
interlocks and emergency stops with two contacts, 1 N.O. & 1 N.C.
Degree of Enclosure
Protection
Terminal Isolation
Max Conductor Size
Terminals
Weight 24V DC unit
110/230V unit
Material & Colour
Housing
Installation Group
Fixing Details
Switching Head
Power Supply
Power Consumption
Internal Fuse
Safety Distance
Aux. Distance
Outputs
Utilization Category (AC)
Features
• Electro-magnetic tamper resistant coding
• Interfaces directly to a safety relay control unit
Specifications
Standards
EN954-1, ISO13849-1, IEC/EN60204-
1, NFPA79, EN1088, ISO14119,
IEC60947-5-1, ANSI B11.19,
AS4024.1
Cat. 3 per EN954-1 (Sensors with
controller)
CE marked for all applicable directives
and cULus
24V AC/DC or 110/230V AC
<6VA
Normally closed contactor loop
1 N.O. & 1 N.C. from Ferrocode head
500 mAT replaceable supply fuse
Mains selector switch
2 N.O. & 1 N.C. T
Ü
V approved
Max Switched DC Current/Volt 1A/28V DC/28W
Min Switched DC Current/Volt 10mA/10V
Max Output Fuse
Indication
Impulse withstand Voltage
Operating Temperature
Contamination Level
Humidity
Degree of Protection
1A quick acting
LED 1
2500V
-10°C to +55°C (14°F to 131°F)
3
90% RH
IP67 (NEMA 6P)
Green 1 = Guard closed
Category
Approvals
Power Supply
Power Consumption
X1-X2 Contactor Monitor
Loop
Safety Inputs
Internal Fuse
Internal Switches
Relay Output
Weight (not including cable)
Switch 30g (0.07lbs)
Actuator 40g (0.09lbs)
Material & Colour
Fixing Details
Cable
Red moulded ABS plastic
M4
0.2 mm
2
(24AWG) 6 wire; Braided
PVC Jacket OD 6mm (0.23in)
3-68

440N-C02078 Related Products

440N-C02078 440N-C02067 440N-C02068
Description Non contact Switches Non contact Switches Non contact Switches
About DSP clock and PLL issues
1. Clock input problem Clock input: There are many clock options for the 280x series DSP, including: Crystal input through X1 and X2: CLKIN needs to be connected to the reference ground, otherwise it ...
Jacktang DSP and ARM Processors
How to select filter capacitors?
[size=4]When the AC voltage output from the secondary side of the transformer is rectified by the diode, a capacitor is connected for filtering. There are some small problems here. U0 is the voltage b...
灞波儿奔 Analogue and Mixed Signal
Domestic simulation software recruits part-time test engineers
[align=left][color=#000000][color=rgb(68, 68, 68)][backcolor=transparent][font=Tahoma,]Company Introduction: [/font][/backcolor][/color] [color=rgb(68, 68, 68)][backcolor=transparent][font=Tahoma,]We ...
faradaydynamics Recruitment
A2B, In-car entertainment network, a new direction
In-car entertainment network, after Ethernet AVB, MOST, etc. A2B has appeared. Friends on the entertainment network should search on Baidu.https://www.analog.com/cn/landing-pages/001/a2b.html...
5525 Automotive Electronics
Phased Array Beamforming IC Simplifies Antenna Design
Wireless communications and radar systems are seeing an increasing demand on antenna architectures to improve performance. Many new applications are only possible with antennas that consume less power...
Aguilera RF/Wirelessly
Communication example between two nodes of SM32W108 wireless RF module
This article writes a program based on the SimpleMac protocol stack of 802.15.4/ZigBee to realize the communication between two STM32W108 wireless nodes. The nodes are divided into SUN nodes and PLANE...
fish001 RF/Wirelessly

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号