Synthesizer , SMT
1780 — 1860 MHz, 50 & 100 & 200 kHz
Features
•
Fully Integrated VCO, PLL, Loop Filter
•
High Performance, Low Cost
•
Miniature SMT Package (LSM6)
MASYVS0006-1810
Rev: F
Description
This synthesizer design integrates a high performance VCO, PLL,
IC and discrete loop filter in a surface mount package. This SMT
package provides electrical shielding, easy PCB assembly and re-
peatable performance. The synthesizer is designed for use in wire-
less base stations.
M/A-COM synthesizers are manufactured in an ISO9001 certified
facility, incorporating surface mount assembly and automated elec-
trical testing. This ensures consistent electrical performance and
quality over volume production quantities.
Electrical Specifications
1
:
T
A
= +25°C, Z
0
= 50 Ohms, V
cc1
= 5V, V
cc2
= 5V.
Parameter
Frequency Range
RF Output Power
Phase Noise
Test Conditions
Over T
op 2
Over T
op 2
SSB at 100 Hz offset from carrier
SSB at 1 kHz offset from carrier
SSB at 10 kHz offset from carrier
SSB at 100 kHz offset from carrier
SSB at 1.0 MHz offset from carrier
100 Hz to 1 MHz bandwidth
Units
MHz
dBm
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
Degree
dBc
Phase comparison frequency
( ± 50 kHz or ± 100 kHz or ± 200 kHz)
Reference breakthrough ( ± 10 MHz)
Frequency Lock Time
VCO Supply Current (I
CC1
)
PLL Supply Current (I
CC2
)
VCO Power Supply (V
CC1
)
PLL Power Supply (V
CC2
)
Over F
out
, Measured to within ± 50 Hz
Recommended operating condition
Recommended operating condition
Recommended operating condition
Recommended operating condition
dBc
dBc
ms
mA
mA
V
V
+4.75
+2.85
Min
1780
-2.5
-70
-70
-99
-122
-142
1.2
-25
-80
-80
20
25
6
+5.00
+5.00
30
10
+5.25
+5.25
Typ
Max
1860
+2.5
-65
-65
-95
-120
-140
1.7
-20
-75
-75
Integrated Phase Noise
Harmonic Suppression
Spurious Suppression
(Non-Harmonic)
1. All specification limits are indicated values @ +25 ºC and apply over F
out
unless otherwise stated.
2. See “Absolute Maximum Ratings” table for T
op
.
1
M/A-COM Inc. and its affiliates reserve the right to make changes to
the product(s) or information contained herein without notice. M/A-
COM makes no warranty, representation or guarantee regarding the
suitability of its products for any particular purpose, nor does M/A-
COM assume any liability whatsoever arising out of the use.
or application of any product(s) or information.
•
North America
Tel: 800.366.2266 / Fax: 978.366.2266
•
Europe
Tel: 44.1908.574.200 / Fax: 44.1908.574.300
•
Asia/Pacific
Tel: 81.44.844.8296 / Fax: 81.44.844.8298
Visit
www.macom.com
for additional data sheets and product information.
Synthesizer , SMT
1780 — 1860 MHz, 50 & 100 & 200 kHz
Electrical Specifications
1
: (cont’d)
Parameter
Step Size (∆F)
Reference Frequency (F
R
)
PLL Programming
PLL Lock Monitor Output
Test Conditions
Recommended operating limit
1.0 V pp ± 0.2V square wave with input filter
Units
kHz
MHz
MASYVS0006-1810
Min
Typ
50/100/200
Max
10
20
3-wire serial CMOS IAW LMX2326, Charge Pump 1 mA
Logic high = V
CC2
x 0.8 Min and Logic low = V
CC2
x 0.2 Max
Locked = V
CC2
- 0.4 Min , Unlocked = 0.4V Max
Pin Configuration
Pin No.
1
2
3
4
5
6
7
Function
V
CC2
GND
REF I/P
GND
V
CC1
GND
RF O/P
Pin No.
8
9
10
11
12
13
14
Function
GND
Lock Detect
Clock
Data
Load Enable
GND
GND
Absolute Maximum Ratings
T
A
= +25°C
Parameter
VCO Supply Voltage (V
CC1
)
PLL Supply Voltage (V
CC2
)
Reference Frequency Level
Data, Clock, Strobe
Voltages
Operating Temperature
Storage Temperature
Solder Assembly
Temperature
Absolute Maximum
-0.3V to 6.5 V
-0.3V to 6.5 V
-0.3V to 6.5 V
-0.3V to V
cc
+ 0.3 V
-40°C to +85°C
-45°C to +120°C
See App Note M2032
Functional Block Diagram
TO CONTROLLER
1. Operation of this device above any one of these parameters
may cause permanent damage.
2. Static sensitive, observe appropriate handling precautions.
13
1
VCC2
10nF
2
GND
DATA
11
GND
LOAD ENABLE
12
Environmental Specifications
Devices are designed to function after exposure to the
shock, vibration, thermal shock and moisture conditions
typically encountered in base station and other infra-
structure environments.
3
REF IN
CLOCK
10
4
GND
LOCK DETECT
9
5
VCC1
10nF
6
GND
GND
14
GND
8
RF OUT
7
Ordering Information
50R
Part Number
MASYVS0006-1810 B
Package
Bulk Packaging
Tape and Reel (300/Reel)
1
Reverse Tape and Reel
(300/Reel)
1
1. The diagram above shows a typical application.
2. The Reference input and RF output are internally AC cou-
pled.
3. The diagram applies when digital lock detect is selected. For
analog open-drain mode, a filter is required.
MASYVS0006-1810 T
MASYVS0006-1810 R
1. See application note M513.
2
M/A-COM Inc. and its affiliates reserve the right to make changes to
the product(s) or information contained herein without notice. M/A-
COM makes no warranty, representation or guarantee regarding the
suitability of its products for any particular purpose, nor does M/A-
COM assume any liability whatsoever arising out of the use.
or application of any product(s) or information.
•
North America
Tel: 800.366.2266 / Fax: 978.366.2266
•
Europe
Tel: 44.1908.574.200 / Fax: 44.1908.574.300
•
Asia/Pacific
Tel: 81.44.844.8296 / Fax: 81.44.844.8298
Visit
www.macom.com
for additional data sheets and product information.
Synthesizer , SMT
1780 — 1860 MHz, 50 & 100 & 200 kHz
Recommended PCB Layout
MASYVS0006-1810
Outline Drawing
1.
2.
Plating: Au, 0.15µm over Ni barrier of 0.5µm.
Internal Solder: Sn95.5/Ag4.0/Cu0.5, lead free.
ECO History
Rev
F
Date
Dec 20, 2004
Description
Extended operating frequency from 1780-1840 MHz to 1780—1860 MHz
By
BH
3
M/A-COM Inc. and its affiliates reserve the right to make changes to
the product(s) or information contained herein without notice. M/A-
COM makes no warranty, representation or guarantee regarding the
suitability of its products for any particular purpose, nor does M/A-
COM assume any liability whatsoever arising out of the use.
or application of any product(s) or information.
•
North America
Tel: 800.366.2266 / Fax: 978.366.2266
•
Europe
Tel: 44.1908.574.200 / Fax: 44.1908.574.300
•
Asia/Pacific
Tel: 81.44.844.8296 / Fax: 81.44.844.8298
Visit
www.macom.com