Electrical Specifications: Freq. = 5 - 1225 MHz, T
A
= 25°C, Z
0
= 75 Ω, P
in
= 0 dBm
Parameter
Impedance Ratio
Insertion Loss 1
(Pin 1 - Pin 3)
Insertion Loss 2
(Pin 1 - Pin 2)
Amplitude Balance
Phase Balance
(ref value 180°)
Input Return Loss
(Pin 1)
Conditions
—
5 - 300 MHz
300 - 1000 MHz
1000 - 1225 MHz
5 - 300 MHz
300 - 1000 MHz
1000 - 1225 MHz
5 - 300 MHz
300 - 1225 MHz
5 - 300 MHz
300 - 1225 MHz
5 - 300 MHz
300 - 1225 MHz
Units
—
dB
dB
dB
dB
dB
Min.
—
—
—
—
—
25
15
Typ.
1:1
0.2
0.4
0.7
0.3
0.5
0.4
0.2
0.4
1.0
2.0
30
25
Max.
—
0.3
0.8
1.0
0.5
0.7
0.8
±0.3
±0.7
±3.0
±9.0
—
Ordering Information
1
Part Number
MABA-011085-PPR
MABA-011085-TB
Description
900 piece reel
sample board
Absolute Maximum Ratings
Parameter
Input RF Power
DC Current
Operating Temperature
Absolute Maximum
2000 mW
1500 mA
-40°C to +125°C
1. All sample boards include 5 loose parts.
1
MACOM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice.
Visit
www.macom.com
for additional data sheets and product information.
For further information and support please visit:
https://www.macom.com/support
DC-0012064
MABA-011085
1:1 Transmission Line Balun with Tertiary Winding
5 - 1225 MHz
Recommended PCB Layout
Rev. V2
Layout Option 1 - no dc voltage on tertiary winding
1.
2.
3.
4.
Recommended PCB layout shown above uses 1.6 mm FR4
Grounded coplanar wave guide transmission line
Trace width 0.70 mm
Gap 0.57 mm
Layout Option 2 - dc voltage on tertiary winding
Application Schematics
Option 1 - no dc voltage on tertiary winding
Option 2 - dc voltage on tertiary winding
Parts List
Component
C1
2
MACOM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice.
Visit
www.macom.com
for additional data sheets and product information.
For further information and support please visit:
https://www.macom.com/support
DC-0012064
Value
10 nF
Package
0402
MABA-011085
1:1 Transmission Line Balun with Tertiary Winding
5 - 1225 MHz
Typical Performance Curves: T
A
= 25°C, Z
0
= 75 Ω, P
IN
= 0 dBm
Rev. V2
Full temperature plots available on request
3
MACOM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice.
Visit
www.macom.com
for additional data sheets and product information.
For further information and support please visit:
https://www.macom.com/support
DC-0012064
MABA-011085
1:1 Transmission Line Balun with Tertiary Winding
5 - 1225 MHz
Part Outline Drawing
Rev. V2
1.
2.
3.
4.
Dimensions in mm
Tolerance: ±0.2 mm unless otherwise noted
Model number and lot code are printed on the reel
Plating finish: ENIG
Carrier Tape Orientation
Tape & Reel Information
Parameter
Qty per reel
Reel Size
Tape Width
Pitch
Orientation
Units
-
mm
mm
mm
-
Value
900
330
16.00
12.00
F60
4
Reference Application Note ANI-019 for orientation
MACOM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice.
Visit
www.macom.com
for additional data sheets and product information.
For further information and support please visit:
https://www.macom.com/support
DC-0012064
MABA-011085
1:1 Transmission Line Balun with Tertiary Winding
5 - 1225 MHz
Rev. V2
MACOM Technology Solutions Inc. All rights reserved.
Information in this document is provided in connection with MACOM Technology Solutions Inc ("MACOM")
products. These materials are provided by MACOM as a service to its customers and may be used for
informational purposes only. Except as provided in MACOM's Terms and Conditions of Sale for such products or
in any separate agreement related to this document, MACOM assumes no liability whatsoever. MACOM
assumes no responsibility for errors or omissions in these materials. MACOM may make changes to
specifications and product descriptions at any time, without notice. MACOM makes no commitment to update
the information and shall have no responsibility whatsoever for conflicts or incompatibilities arising from future
changes to its specifications and product descriptions. No license, express or implied, by estoppels or otherwise,
to any intellectual property rights is granted by this document.
THESE MATERIALS ARE PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESS OR
IMPLIED, RELATING TO SALE AND/OR USE OF MACOM PRODUCTS INCLUDING LIABILITY OR
WARRANTIES RELATING TO FITNESS FOR A PARTICULAR PURPOSE, CONSEQUENTIAL OR
INCIDENTAL DAMAGES, MERCHANTABILITY, OR INFRINGEMENT OF ANY PATENT, COPYRIGHT OR
OTHER INTELLECTUAL PROPERTY RIGHT. MACOM FURTHER DOES NOT WARRANT THE ACCURACY
OR COMPLETENESS OF THE INFORMATION, TEXT, GRAPHICS OR OTHER ITEMS CONTAINED WITHIN
THESE MATERIALS. MACOM SHALL NOT BE LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL, OR
CONSEQUENTIAL DAMAGES, INCLUDING WITHOUT LIMITATION, LOST REVENUES OR LOST PROFITS,
WHICH MAY RESULT FROM THE USE OF THESE MATERIALS.
MACOM products are not intended for use in medical, lifesaving or life sustaining applications. MACOM
customers using or selling MACOM products for use in such applications do so at their own risk and agree to
fully indemnify MACOM for any damages resulting from such improper use or sale.
5
MACOM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice.
Visit
www.macom.com
for additional data sheets and product information.