XMLP600PP130
pressure transmitter - XMLP - 600psi - 1/4"18NPT
- 0,5..4,5V - Packard - set 1
Main
Range of product
Product or component type
Pressure sensor type
Pressure sensor name
Electrical circuit type
Pressure sensor size
Local display
Controlled fluid
OsiSense XM
Electronic pressure sensors
Pressure transmitter
XMLP
Control circuit
600 psi
Without
Fresh water 0...135 °C
Air -40...135 °C
Hydraulic oil -40...135 °C
Gas -40...135 °C
Refrigeration fluid -40...135 °C
1/4" - 18 NPT (male)
1 male connector Packard Metripack 150 3 pins
5 V DC SELV, voltage limits: 4.5...5.5 V
< 7 mA
Analogue
0.5...4.5 V, 3-wire
Set of 1
Individual
Fluid connection type
Electrical connection
[Us] rated supply voltage
Current consumption
Type of output signal
Analogue output function
Quantity per set
Type of packing
Complementary
Pressure setting range
Maximum permissible accidental
pressure
Destruction pressure
Materials in contact with fluid
Operating position
Protection type
May 10, 2018
0...600 psi
1800 psi
3600 psi
Stainless steel AISI 316L
Any position
Load short-circuit
1
Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications
Reverse polarity
Electromagnetic compatibility
1.2/50 µs shock waves immunity test conforming to EN/IEC 61000-4-5 - test level 1 kV (f = 42 Ohm)
Immunity to magnetic fields conforming to EN/IEC 61000-4-8 - test level 100 A/m (f = 50 Hz)
Susceptibility to electromagnetic fields conforming to EN/IEC 61000-4-3 - test level 10 V/m (f =
80...3000 MHz)
Radiated RF fields conforming to EN/IEC 61000-4-6 - test level 10 V (f = 0.01...80 MHz)
Electrical fast transient/burst immunity test conforming to EN/IEC 61000-4-4 - test level 2 kV
Electrostatic discharge immunity test conforming to EN/IEC 61000-4-2 - test level 8 kV air, 4 kV
contact
0.5 kV
<= 2 ms for 10...90 % of full scale
+/- 0.5 % of the measuring range
0.1 % of the measuring range
+/- 0.02 % of measuring range/°K
+/- 0.02 % of measuring range/°K
>= 10000000 cycles
0.09 kg
26 mm
55 mm
[Uimp] rated impulse withstand voltage
Response time on output
Measurement accuracy
Accuracy
Drift of the sensitivity
Drift of the zero point
Mechanical durability
Product weight
Diameter
Length
Environment
Standards
Product certifications
EN/IEC 61326-2-3
NSF ANSI 61
CULus
RCM
EAC
CE
TC
-30...85 °C
-50...100 °C
20 gn (f = 15...2000 Hz) conforming to EN/IEC 60068-2-6
100 gn for 11 ms conforming to EN/IEC 60068-2-27
IP65 conforming to EN/IEC 60529
IP67 conforming to EN/IEC 60529
Protective treatment
Ambient air temperature for operation
Ambient air temperature for storage
Vibration resistance
Shock resistance
IP degree of protection
Offer Sustainability
Sustainable offer status
RoHS (date code: YYWW)
REACh
Product environmental profile
Product end of life instructions
Green Premium product
Compliant - since 1723 - Schneider Electric declaration of conformity
Schneider Electric declaration of conformity
Reference not containing SVHC above the threshold
Reference not containing SVHC above the threshold
Available
Need no specific recycling operations