Halogen and Antimony Free. “Green” Device (Note 3)
Applications
•
•
•
•
•
•
•
•
Position and Proximity Sensing in Automotive Applications
Open and Close Detect
Position Detect
Level Detect
Flow Meters
Contactless Switches
Seatbelt Buckle
Seat Position
•
•
•
•
•
•
•
•
Notes:
1. No purposely added lead. Fully EU Directive 2002/95/EC (RoHS), 2011/65/EU (RoHS 2) & 2015/863/EU (RoHS 3) compliant.
2. See https://www.diodes.com/quality/lead-free/ for more information about Diodes Incorporated’s definitions of Halogen- and Antimony-free, "Green" and
Lead-free.
3. Halogen- and Antimony-free "Green” products are defined as those which contain <900ppm bromine, <900ppm chlorine (<1500ppm total Br + Cl) and
Electros Static Discharge Withstand—Human Body Model (HMB)
Electros Static Discharge Withstand—Machine Model (MM)
Electros Static Discharge Withstand—Charged Device Model (CDM)
SIP-3 (Ammo Pack),
SIP-3 (Bulk Pack)
SOT23
Value
32
-32
32
60
-50
Unlimited
550
230
-65 to +165
+150
8
800
2
Unit
V
V
V
mA
mA
mW
°C
°C
kV
V
kV
5. Stresses greater than the 'Absolute Maximum Ratings' specified above may cause permanent damage to the device. These are stress ratings only;
functional operation of the device at these or any other conditions exceeding those indicated in this specification is not implied. Device reliability may be
affected by exposure to absolute maximum rating conditions for extended periods of time.
6. The absolute maximum V
DD
of 32V is a transient stress rating and is not meant as a functional operating condition. It is not recommended to operate
the device at the absolute maximum rated conditions for any period of time.
Recommended Operating Conditions
(@T
A
= -40°C to +150°C, unless otherwise specified.)
Symbol
V
DD
T
A
Parameter
Supply Voltage
Operating Temperature Range
Operating
Operating
Condition
Rating
3.0 to 28
-40 to +150
Unit
V
°C
Electrical Characteristics
(Note 7 & 8) (@T
A
= -40°C to +150°C, V
DD
= 3V to 28V, unless otherwise specified.)
Symbol
V
OUT_ON
I
LKG
I
DD
Parameter
Output ON Voltage
Output Leakage Current
(When Output is Off)
Supply Current
Condition
I
OUT
= 20mA, B > B
OP
V
OUT
= 28V, B < B
RP
, Output Off
Output open, T
A
= +25°C
Output open, T
A
= -40°C to +150°C
V
DD
= -18V, T
A
= +25°C
V
DD
= -18V, T
A
= -40°C to +150°C
V
DD
= -28V, T
A
= +25°C
V
DD
= -28V, T
A
= -40°C to +150°C
V
DD
>= 3V, B > B
OP
(Note 7)
—
(Note 9)
R
L
= 1kΩ, C
L
= 20pF
R
L
= 1kΩ, C
L
= 20pF
B > B
OP
, (Note 10 )
I
DD
= 5mA
Min
—
—
—
—
—
—
—
—
—
—
—
Typ
0.2
<0.1
3
-
0.6
0.6
1.6
1.6
10
800
3.75
Max
0.4
10
3.5
4
—
1500
—
2500
—
—
—
Unit
V
µA
mA
mA
µA
µA
µA
µA
µs
kHz
µs
I
DD_R
Reverse Supply Current
t
P_ON
f
C
t
D
t
R
t
F
I
OCL
V
Z
Notes:
Device Power-on Time (Start-up Time)
Chopping Frequency
Response Time Delay
(Time from Magnetic Threshold Reached
to the Start of the Output Rise or Fall)
Output Rising Time
(External Pull-up Resistor R
L
and Load
Capacitance Dependent)
Output Falling Time
(Internal Switch Resistance and Load
Capacitance Dependent)
Output Current Limit
Zener Clamp Voltage
—
0.2
1
µs
—
30
28
0.1
—
—
1
55
—
µs
mA
V
7. When power is initially turned on, V
DD
must be within its correct operating range (3.0V to 28V) to guarantee the output sampling. The output state is valid
after the start-up time of 10µs typical
from the operating voltage reaching 3V.
8. Typical values are defined at T
A
= +25°C, V
DD
= 12V. Maximum and minimum values over the operating temperature range is not tested in production but
guaranteed by design, process control, and characterization.
9. Guaranteed by design, process control, and characterization. Not tested in production.