TR30RDM050-12G02-RD-BK-Level-VI

Description
Wall Mount AC Adapter Switching Adapter, Level VI, Wallmount, Medical, 30 Watt, 80-264VAC Input, 5VDC Output, 5.0A, 5.5x2.5x12mm Straight, DC Cable 1220mm, UL1571 with OVP, Red-Black
CategoryPower/power management    Plug in ac adapter    Wall mounted AC adapter   
File Size406KB,4 Pages
ManufacturerCincon
Environmental Compliance
Download Datasheet Parametric View All

TR30RDM050-12G02-RD-BK-Level-VI Online Shopping

Suppliers Part Number Price MOQ In stock  
TR30RDM050-12G02-RD-BK-Level-VI - - View Buy Now

TR30RDM050-12G02-RD-BK-Level-VI Overview

Wall Mount AC Adapter Switching Adapter, Level VI, Wallmount, Medical, 30 Watt, 80-264VAC Input, 5VDC Output, 5.0A, 5.5x2.5x12mm Straight, DC Cable 1220mm, UL1571 with OVP, Red-Black

TR30RDM050-12G02-RD-BK-Level-VI Parametric

Parameter NameAttribute value
MakerCincon
Product CategoryWall Mount AC Adapter
AC plug included/requiredIncluded
areaAustralia, Europe, North America, United Kingdom
productInterchangeable Plug
Input voltage80 VAC to 264 VAC
Number of outputs1 Output
Output Power30 W
Output voltage—channel 15 V
Output current—channel 15 A
industryMedical
DC output connectorRight Angle Barrel Plug
DC output wire length1220 mm
efficiencyLevel VI
seriesTR30RDM
CertificationEN 60601-1, IEC 60601-1, ANSI/AAMI ES60601-1
Installation styleWall Mount
load regulationRegulated
Maximum operating temperature+ 60 C
Minimum operating temperature- 20 C
Factory packaging quantity1
V10
Features
* Universal Input Range 80~264VAC
* Interchangeable AC Plugs
* Approved EN55011, FCC CFR47 Part 18 Class B
* Meets EN60335-1
* Approved EN60601-1-11 for Home Care Applications
* Low Leakage Current <50uA
* Meets IP21
* Continuous Short Circuit Protection
* Over Voltage Protection
* Meet CoC Tier 2 & DoE Level VI
(Output Cable Length
1800mm)
(TR30RDM050: Output Cable Length
1220mm)
* No Load Power Consumption<75mW
* 2MOPP Class II
TR30RDM
SERIES
30W MEDICAL
SWITCHING ADAPTER
Ordering information
TR30RDMXXX
-XX
G
UL1571 WITH OVP
XX
DC Cable Length and Type
01: 720mm
02: 1220mm
03: 1800mm
11: 720mm with Ferrite Core
12: 1220mm with Ferrite Core
13: 1800mm with Ferrite Core
* 16AWG / UL1571 or Equivalent for Vo: 5V, 9V
* 18AWG / UL1571 or Equivalent for Vo: 12V, 15V
* 22AWG / UL1571 or Equivalent for Vo: 18V, 24V
-XX-BK
Color of Top
Case
BK-BK : Black-Black
BE-BK : Blue-Black
RD-BK : Red-Black
Model No.
DC Plug Type
MODEL
TR30RDM050
TR30RDM090
TR30RDM120
TR30RDM150
TR30RDM180
TR30RDM240
OUTPUT
VOLTAGE
5V
9V
12V
15V
18V
24V
OUTPUT
CURRENT
5.0A
3.3A
2.5A
2.0A
1.67A
1.25A
RIPPLE &
NOISE
NOTE 1
100mVp-p
100mVp-p
120mVp-p
120mVp-p
120mVp-p
120mVp-p
VOLTAGE
ACCURACY
NOTE 2
±2%
±2%
±2%
±2%
±2%
±2%
LINE
REGULATION
NOTE 3
±1%
±1%
±1%
±1%
±1%
±1%
LOAD
REGULATION
NOET 4
±6%
±3%
±2%
±2%
±2%
±2%
% EFF. (Typ.)
NOTE 5
84%
88%
88%
88%
88%
88%
Specifications are subject to change without notice.
1
[Help] Dear electronic engineers, what did you mention when you first went back to the girl's house?
I have been with my girlfriend for more than four years, two years for studying and two years for working. Due to the epidemic, I have not been able to go to her house. I will take advantage of the Ob...
吾妻思萌 Talking
Popular Science: What is LPWA?
1 Definition of LPWA LPWA – Low power wide area, short for low power wide area technology, uses lower power consumption to achieve long-distance wireless signal transmission. Compared with familiar te...
灞波儿奔 RF/Wirelessly
EEWORLD University Hall----Intel FPGA 2019 Engineer Application Video
Intel FPGA 2019 Engineer Application Video : https://training.eeworld.com.cn/course/5153Intel FPGA training course, dynamic configuration, hard-core processor...
抛砖引玉 FPGA/CPLD
Which is better, UHF wireless microphone or 2.4g wireless microphone?
2.4g is better 2.4g will not be interfered by wireless signals from mobile phones, nor will there be crosstalk from several nearby microphones. It has good confidentiality, is not easy to be demodulat...
jp2109 RF/Wirelessly
Pingtouge RISC-V Development Board--STEP1--Impression
[i=s]This post was last edited by ylyfxzsx on 2022-2-23 11:36[/i]RISC-V has been one of the hottest topics in the electronics industry since last year. Especially after reading various articles and pu...
ylyfxzsx XuanTie RISC-V Activity Zone
Silicon Labs development kit review + information about on-board sensors
The hardware distribution on the development board is described in detail in the user manual. The board integrates the temperature and humidity sensor Si7021, the ambient light sensor VEML6035, the Ha...
yin_wu_qing Development Kits Review Area

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号