EEWORLDEEWORLDEEWORLD

Part Number

Search
 PDF

TPP 100-112A-J

Description
AC/DC power module 100W 12V 8.34A 2X4 Med. Open
CategoryPower/power management    AC/DC power supply module   
File Size402KB,4 Pages
ManufacturerTraco Power
Websitehttps://www.tracopower.com/
Environmental Compliance
Download Datasheet Parametric Compare View All

TPP 100-112A-J Overview

AC/DC power module 100W 12V 8.34A 2X4 Med. Open

TPP 100-112A-J Parametric

Parameter NameAttribute value
MakerTraco Power
Product CategoryAC/DC power module
Output Power100 W
Input voltage85 VAC to 264 VAC, 120 VDC to 370 VDC
Number of outputs1 Output
Output voltage—channel 112 V
Output current—channel 18.34 A
length76.2 mm
width50.8 mm
high29.5 mm
industryMedical
seriesTPP 100A-J
input frequency47 Hz to 63 Hz
Insulation voltage4000 Vrms
open frame/closedOpen Frame
EncapsulationBulk
Installation styleChassis
load regulationRegulated
Maximum operating temperature+ 85 C
Minimum operating temperature- 25 C
Factory packaging quantity1
unit weight156 g

TPP 100-112A-J Related Products

TPP 100-112A-J TPP 100-148A-J TPP 100-115A-J TPP 100-124A-J TPP 100-136A-J TPP 100-128A-J
Description AC/DC power module 100W 12V 8.34A 2X4 Med. Open AC/DC power module 100W 48V 2090mA 2X4 Med. Open AC/DC power module 100W 15V 6.67A 2X4 Med. Open AC/DC power module 100W 24V 4170mA 2X4 Med. Open AC/DC power module 100W 36V 2780mA 2X4 Med. Open AC/DC power module 100W 28V 3580mA 2X4 Med. Open
Maker Traco Power Traco Power Traco Power Traco Power Traco Power Traco Power
Product Category AC/DC power module AC/DC power module AC/DC power module AC/DC power module AC/DC power module AC/DC power module
Output Power 100 W 100 W 100 W 100 W 100 W 100 W
Input voltage 85 VAC to 264 VAC, 120 VDC to 370 VDC 85 VAC to 264 VAC, 120 VDC to 370 VDC 85 VAC to 264 VAC, 120 VDC to 370 VDC 85 VAC to 264 VAC, 120 VDC to 370 VDC 85 VAC to 264 VAC, 120 VDC to 370 VDC 85 VAC to 264 VAC, 120 VDC to 370 VDC
Number of outputs 1 Output 1 Output 1 Output 1 Output 1 Output 1 Output
Output voltage—channel 1 12 V 48 V 15 V 24 V 24 V 28 V
Output current—channel 1 8.34 A 2.09 A 6.67 A 4.17 A 2.78 A 3.58 A
length 76.2 mm 76.2 mm 76.2 mm 76.2 mm 76.2 mm 76.2 mm
width 50.8 mm 50.8 mm 50.8 mm 50.8 mm 50.8 mm 50.8 mm
high 29.5 mm 29.5 mm 29.5 mm 29.5 mm 29.5 mm 29.5 mm
industry Medical Medical Medical Medical Medical Medical
series TPP 100A-J TPP 100A-J TPP 100A-J TPP 100A-J TPP 100A-J TPP 100A-J
input frequency 47 Hz to 63 Hz 47 Hz to 63 Hz 47 Hz to 63 Hz 47 Hz to 63 Hz 47 Hz to 63 Hz 47 Hz to 63 Hz
Insulation voltage 4000 Vrms 4000 Vrms 4000 Vrms 4000 Vrms 4000 Vrms 4000 Vrms
open frame/closed Open Frame Open Frame Open Frame Open Frame Open Frame Open Frame
Encapsulation Bulk Bulk Bulk Bulk Bulk Bulk
Installation style Chassis Chassis Chassis Chassis Chassis Chassis
load regulation Regulated Regulated Regulated Regulated Regulated Regulated
Maximum operating temperature + 85 C + 85 C + 85 C + 85 C + 85 C + 85 C
Minimum operating temperature - 25 C - 25 C - 25 C - 25 C - 25 C - 25 C
Factory packaging quantity 1 1 1 1 1 1
unit weight 156 g 156 g 156 g 156 g 156 g 156 g
Shipping restrictions - Mouser does not currently sell this product. Mouser does not currently sell this product. Mouser does not currently sell this product. Mouser does not currently sell this product. Mouser does not currently sell this product.
Disassemble and see what's inside the Mercedes-Benz computer board that's been soaked in water!
This is the SAM module of a water-soaked Mercedes-Benz car, and it looks clean on the outside.Judging from the label, it is produced by Hella and made in Romania.From the side, there is a lot of dried...
littleshrimp Automotive Electronics
Satellite Temperature Sensing Reference Design
This reference design describes a satellite temperature sensing reference design. This reference design illustrates various methods of remotely acquiring temperature data on a subsystem using the MSP4...
Jacktang Microcontroller MCU
Good luck to the start of 2022, set a flag and grab a building to get a gift~ Break the magic of "set it up and it will fall down"
Awards have been awardedHi, fellow forum membersSay goodbye to the Spring Festival days of eating, drinking and playing~Let's start the journey of working in the frontline together... At the beginning...
EEWORLD社区 Talking
"Deciphering the MCU" legend!
It seems that there is no such encryption solution that can be solved once and for all. I will talk about the cracking incidents I know about. Although most of them are hearsay, I guess the credibilit...
bigbat MCU
[Mill MYB-YT507 development board trial experience] Use tornado to quickly create a web server
1. Install the tprnado module: atp install python3-tornado 2. Create files on the web server: #!/usr/bin/env python # -*- coding:utf-8 -*-import tornado.ioloop import tornado.webclass MainHandler(torn...
lugl4313820 Domestic Chip Exchange
Common failure modes of resistors
[align=center][b]Common failure modes of resistors[/b][/align][align=left] Failure mode: various failure phenomena and their manifestations. [/align][align=left] Failure mechanism: physical, chemical,...
yezhan2019 TI Technology Forum

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号