Surge protection device - D-UFB-V24/8-BS-B - 2782106
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's
documentation. Our General Terms of Use for Downloads are valid
(http://phoenixcontact.com/download)
Attachment plug with surge voltage fine protection for V.24 interface with handshake. Connection: D-SUB-25
socket/plug, for installation in lines
The figure shows version D-UFB-
V24/SB-S
Key Commercial Data
Packing unit
GTIN
GTIN
4017918069346
1 pc
Technical data
Dimensions
Height
Width
Length
54.5 mm
24.5 mm
84.6 mm
Ambient conditions
Ambient temperature (operation)
Degree of protection
-40 °C ... 60 °C
IP20
General
Housing material
Color
Standards for cearances and creepage distances
Mounting type
Type
Direction of action
Aluminum
black
VDE 0110-1
IEC 60664-1
Connection-specific intermediate plugging
Attachment plug
Line-Line & Line-Signal Ground/Shield & Signal Ground/Shield-Earth
Ground
11/05/2018 Page 1 / 3
https://www.phoenixcontact.com/pi/products/2782106
Surge protection device - D-UFB-V24/8-BS-B - 2782106
Technical data
Protective circuit
IEC test classification
VDE requirement class
Maximum continuous voltage U
C
(line-signalground)
Nominal current I
N
Operating effective current I
C
at U
C
Residual current I
PE
Nominal discharge current I
n
(8/20) µs (line-line)
Nominal discharge current I
n
(8/20) µs (line-earth)
Nominal discharge current I
n
(8/20) µs (signalground-earth)
Total surge current (8/20) µs
Max. discharge current I
max
(8/20) µs maximum (line-earth)
Nominal pulse current Ian (10/1000) µs (line-earth)
Output voltage limitation at 1 kV/µs (line-earth) spike
Output voltage limitation at 1 kV/µs (line-signalground) spike
Output voltage limitation at 1 kV/µs (line-shield) spike
Output voltage limitation at 1 kV/µs (line-earth) static
Output voltage limitation at 1 kV/µs (line-signalground) static
Residual voltage at I
n
(line-signalground)
Residual voltage with Ian (10/1000) µs (line-signalground)
Voltage protection level U
p
(line-earth)
Voltage protection level U
p
(line-signalground)
Response time t
A
(line-line)
Response time tA (line-signalground)
Response time t
A
(line-earth)
Input attenuation aE, asym.
Cut-off frequency fg (3 dB), asym. (GND) in 50 Ohm system
Cut-off frequency fg (3 dB), asym. (GND) in 600 Ohm system
Impulse durability (line-line)
Impulse durability (line-earth)
C1
C3
C1
C3
15 V DC
1 A (60 °C)
≤ 5 µA
≤ 1 µA
300 A
300 A
5 kA
5 kA
300 A
59 A
≤ 600 V
≤ 22 V
≤ 22 V
≤ 600 V
≤ 22 V
≤ 28 V
≤ 25 V
≤ 600 V
≤ 28 V
≤ 1 ns
≤ 1 ns
≤ 100 ns
0.1 dB (≤ 700 kHz)
0.1 dB (≤ 50 kHz)
typ. 4 MHz
typ. 300 kHz
C1 - 500 V / 250 A
C1 - 500 V / 250 A
C3 - 25 A
Connection data
Connection method
Connection method IN
Connection method OUT
Connection technology
D-SUB 25
D-SUB-25 socket
D-SUB-25 male connector
V.24
Standards and Regulations
11/05/2018 Page 2 / 3
https://www.phoenixcontact.com/pi/products/2782106
Surge protection device - D-UFB-V24/8-BS-B - 2782106
Technical data
Standards and Regulations
Standards/regulations
IEC 61643-21
Drawings
Dimensional drawing
85
16
1
TxD 2
RxD 3
RTS 4
1
2
3
4
5
6
8
20
7
Circuit diagram
54,5
IN
CTS 5
DSR 6
DCD 8
DTR 20
Gnd 7
OUT
Phoenix Contact 2018 © - all rights reserved
http://www.phoenixcontact.com
PHOENIX CONTACT GmbH & Co. KG
Flachsmarktstr. 8
32825 Blomberg
Germany
Tel. +49 5235 300
Fax +49 5235 3 41200
http://www.phoenixcontact.com
11/05/2018 Page 3 / 3