The models in this table are UL/CSA certified. This is indicated with a certification mark on the products.
(This does not include models with high contact reliability or plastic sealed, latching, or hermetically sealed models.)
2.
Models with an asterisk (*) next to them are new versions.
3.
The standard models with plug-in terminals, models with coil surge absorption diodes, and models with coil surge absorption CR circuits were used in
combination with the PYF-E and PYFS (2-pole and 4-pole) for the EC Declaration of Conformity. These products display the CE Marking.
4.
Products cannot be manufactured for the cells with a diagonal line. Ask your OMRON representative for details on manufacturing products for cells containing
“---” in the above table.
2
4
MYQ4Z
MY2K
MY4H
MYQ4Z-02
MY2K-02
MY4H-0
4 Bifurcated
4
MYQ4N
---
Without operation
indicator
MY2*
MY2Z
MY3
MY4*
MY4Z*
MY2-D*
MY2Z-D
MY3-D
MY4-D*
MY4Z-D*
MY2-CR*
MY4-CR*
MY4Z-CR*
MY4Z-CBG
MYQ4
MYQ4-02
MY4IN-CR(S)*
MY4ZIN-CR(S)*
---
MY4IN-D2(S)*
MY4ZIN-D2(S)*
---
---
MY4IN(S)*
MY4ZIN(S)*
MY2IN-D2(S)*
MY3-02
MY4-02
MY4Z-02
MY3F
MY4F
MY4ZF
With latching lever
MY2IN(S)*
MY2-02
MY2F
PCB terminals
Case-surface
mounting
Refer to
Connection Socket and Mounting Bracket Selection Table on page 33
in
Options
for information on the
possible combinations of Models with Plug-in Terminals and Sockets.
1
MY
Miniature Power Relays: MY2
Refer to the standards certifications and compliance
section of your OMRON website for the latest
information on certified models.
Ordering Information
Classification
When your order, specify the rated voltage.
Rated voltage (V)
Standard products
12, 24, 100/110, or 200/220 VAC
12, 24, 48, or 100/110 VDC
12, 24, 100/110, 110/120, 200/220, or 220/240 VAC
12, 24, 48, or 100/110 VDC
12, 24, or 100/110 VDC
12, 24, 48, or 100/110 VDC
100/110 or 200/220 VAC
100/110 or 200/220 VAC
110/120 or 220/240 VAC
110/120 or 220/240 VAC
48 VDC
Made-to-order items
110/120 or 220/240 VAC
Model
Standard models
MY2
Models with built-in operation indicators
Models with built-in diodes
Models with built-in diodes and operation
indicators
Models with built-in CR circuits
Models with built-in CR circuits and operation
indicators
MY2N
MY2-D
MY2N-D2
MY2-CR
MY2N-CR
Note: 1.
Ask your OMRON representative for details on the time required to deliver made-to-order products.
2.
Ask your OMRON representative for details on product specifications and the ability to manufacture products with voltages other than
the above coil specifications.
3.
The above models and specifications are new versions in the MY Series.
4.
Except for MY2(N)-CR Relays with the above voltage specifications, all Relays have a height of 53 mm or less.
If Mounting Brackets are required, refer to page 33 for selection information.
Ratings and Specifications
Ratings
Operating Coils (Standard Models)
Item
Rated
voltage (V)
12
24
AC
100/110
110/120
200/220
220/240
12
DC
24
48
100/110
Rated current (mA)
50 Hz
106.5
53.8
11.7/12.9
9.9/10.8
6.2/6.8
4.8/5.3
72.7
36.3
17.6
8.7/9.6
60 Hz
91
46
10/11
8.4/9.2
5.3/5.8
4.2/4.6
Coil resistance
(Ω)
46
180
3,750
4,430
12,950
18,790
165
662
2,725
11,440
Coil inductance (H)
Armature
OFF
0.17
0.69
14.54
19.2
54.75
83.5
0.73
3.2
10.6
45.6
Armature
ON
0.33
1.3
24.6
32.1
94.07
136.4
1.37
5.72
21.0
86.2
10% min.
*2
Approx. 0.9
80% max.
*1
30% min.
*2
110% of rated
voltage
Approx. 0.9 to 1.1
(at 60 Hz)
Must-
operate
voltage (V)
Must-
release
voltage (V)
Maximum
voltage (V)
Power consumption
(VA, W)
Approx. 1.0 to 1.2
(at 60 Hz)
Note: 1.
The rated current and coil resistance are measured at a coil temperature of 23°C with tolerances of +15%/−20% for the AC rated current and ±15% for the
DC coil resistance.
2.
The AC coil resistance and inductance values are reference values only (at 60 Hz).
3.
Operating characteristics were measured at a coil temperature of 23°C.
4.
The maximum voltage capacity was measured at an ambient temperature of 23°C.
*1.
There is variation between products, but actual values are 80% max.
To ensure operation, apply at least 80% of the rated value (at a coil temperature of +23° C).
*2.
There is variation between products, but actual values are 30% minimum for AC and 10% minimum for DC. To ensure release, use a value that is lower than the
specified value.
Contact Ratings
Load
Item
Rated load
Rated carry current
Maximum contact voltage
Maximum contact current
Contact configuration
Contact structure
Contact materials
Resistive load
5 A at 220 VAC
5 A at 24 VDC
5A
250 VAC, 125 VDC
5A
DPDT
Single
Ag
Inductive load
(cos
φ
= 0.4, L/R = 7 ms)
2 A at 220 VAC
2 A at 24 VDC
Type
Item
Ambient
operating
temperature
*1
Ambient
operating
humidity
Standard
models
−55
to 70°C
Model with built-in operation
indicator, diode, or CR circuit
−55
to 60°C
*2
5% to 85%
*1.
With no icing or condensation.
*2.
This limitation is due to the diode junction temperature and elements used.
2
MY
Characteristics
Item
Contact resistance
*1
Operation time
Release time
*2
Maximum
operating
frequency
Mechanical
Rated load
*2
Type
Standard
models
50 mΩ max.
20 ms max.
20 ms max.
Models with built-
in operation
indicators
Models with
built-in CR
circuits
Models with
built-in
diodes
Model with built-in
operation indicator
and diode
Model with built-in
operation indicator
and CR circuit
18,000 operations/h
1,800 operations/h
100 MΩ min.
2,000 VAC at 50/60 Hz for 1 min.
Insulation resistance
*3
Between coil and contacts
Dielectric
strength
Between contacts of
different polarity
Between contacts of the
same polarity
Vibration
resistance
Shock
resistance
Destruction
Malfunction
Destruction
Malfunction
Mechanical
Endurance
Electrical
*4
1,000 VAC at 50/60 Hz for 1 min.
10 to 55 to 10 Hz, 0.5-mm single amplitude (1.0-mm double amplitude)
10 to 55 to 10 Hz, 0.5-mm single amplitude (1.0-mm double amplitude)
Measurement conditions: 1 A at 5 VDC using the voltage drop method.
*2.
Measurement conditions: With rated operating power applied.
Ambient temperature condition: 23° C
*3.
Measurement conditions: For 500 VDC applied to the same location as for dielectric strength
measurement.
*4.
Ambient temperature condition: 23°C
*5.
This value was measured at a switching frequency of 120 operations per minute.
Dimensions
MY2, MY2N, MY2-D, MY2N-D2, MY2-CR,
and MY2N-CR
Terminal Arrangement/In-
ternal Connections
(Bottom View)
Standard Models
MY2N
DC Models
(Unit: mm)
AC Models
2.6
Eight, 1.2-dia. × 2.2 oval holes
0.5
28 max.
(The coil has no polarity.)
36 max.
6.4
21.5 max.
Check the coil polarity when wiring
and wire all connections correctly.
(The coil has no polarity.)
Note: 1.
An AC model has coil disconnection self-
diagnosis.
2.
For the DC models, check the coil polarity when
wiring and wire all connections correctly.
3.
The indicator is red for AC and green for DC.
4.
The operation indicator indicates the
energization of the coil and does not represent
contact operation.
MY2-D
MY2N-D2
MY2-CR
MY2N-CR
Check the coil polarity when wiring
and wire all connections correctly.
Check the coil polarity when wiring
and wire all connections correctly.
(The coil has no polarity.)
(The coil has no polarity.)
3
MY
Miniature Power Relays: MY2Z
Refer to the standards certifications and compliance
section of your OMRON website for the latest
information on certified models.
Ordering Information
Classification
When your order, specify the rated voltage.
Rated voltage (V)
Standard products
100/110 or 200/220 VAC
12 or 24 VDC
100/110 or 200/220 VAC
24 VDC
24 VDC
24 or 100/110 VDC
Made-to-order items
12, 24, 100/120, or 200/240 VAC
48 or 100/110 VDC
12, 24, 100/120, or 200/240 VAC
12, 48, or 100/110 VDC
12 or 100/110 VDC
12 VDC
100/110 or 200/220 VAC
100/110 VAC
200/220 VAC
Model
Standard models
MY2Z
Models with built-in operation indicators
Models with built-in diodes
Models with built-in diodes and operation
indicators
Models with built-in CR circuits
Models with built-in CR circuits and operation
indicators
MY2ZN
MY2Z-D
MY2ZN-D2
MY2Z-CR
MY2ZN-CR
Note: 1.
Ask your OMRON representative for details on the time required to deliver made-to-order products.
2.
Ask your OMRON representative for details on product specifications and the ability to manufacture products with voltages other than
the above coil specifications.
Ratings and Specifications
Ratings
Operating Coil (Standard Models)
Item
Rated
voltage (V)
12
24
AC
100/110
110/120
200/220
220/240
12
DC
24
48
100/110
Rated current (mA)
50 Hz
106.5
53.8
11.7/12.9
9.9/10.8
6.2/6.8
4.8/5.3
75
36.9
18.5
9.1/10
60 Hz
91
46
10/11
8.4/9.2
5.3/5.8
4.2/4.6
Coil resistance
(Ω)
46
180
3,750
4,430
12,950
18,790
160
650
2,600
11,000
Coil inductance (H)
Armature
OFF
0.17
0.69
14.54
19.2
54.75
83.5
0.73
3.2
10.6
45.6
Armature
ON
0.33
1.3
24.6
32.1
94.07
136.4
1.37
5.72
21.0
86.2
10% min.
*2
Approx. 0.9
80% max.
*1
30% min.
*2
110% of rated
voltage
Approx. 0.9 to 1.1
(at 60 Hz)
Must-
operate
voltage (V)
Must-
release
voltage (V)
Maximum
voltage (V)
Power consumption
(VA, W)
Approx. 1.0 to 1.2
(at 60 Hz)
Note: 1.
The rated current and coil resistance are measured at a coil temperature of 23°C with tolerances of +15%/−20% for the AC rated current and ±15% for the
DC coil resistance.
2.
The AC coil resistance and inductance values are reference values only (at 60 Hz).
3.
Operating characteristics were measured at a coil temperature of 23°C.
4.
The maximum voltage capacity was measured at an ambient temperature of 23°C.
*1.
There is variation between products, but actual values are 80% max.
To ensure operation, apply at least 80% of the rated value
*2.
There is variation between products, but actual values are 30% minimum for AC and 10% minimum for DC. To ensure release, use a value that is lower than the
specified value.
Contact Ratings
Load
Item
Rated load
Rated carry current
Maximum contact voltage
Maximum contact current
Contact configuration
Contact structure
Contact materials
Resistive load
5 A at 220 VAC
5 A at 24 VDC
5A
250 VAC, 125 VDC
5A
DPDT
Bifurcated
Au plating + Ag
Inductive load
(cos
φ
= 0.4, L/R = 7 ms)
2 A at 220 VAC
2 A at 24 VDC
Type
Item
Ambient
operating
temperature
*1
Ambient
operating
humidity
Standard
models
−55
to 70° C
Model with built-in operation
indicator, diode, or CR circuit
−55
to 60° C
*2
5% to 85%
*1.
With no icing or condensation.
*2.
This limitation is due to the diode junction temperature and elements used.
4
MY
Characteristics
Item
Contact resistance
*1
Operation time
Release time
*2
Maximum
operating
frequency
Mechanical
Rated load
*2
Type
Standard
models
50 mΩ max.
20 ms max.
20 ms max.
Models with built-
in operation
indicators
Models with
built-in
diodes
Model with built-in
operation indicator
and diode
Models with
built-in CR
circuits
Models with built-in
CR circuits and
operation indicators
18,000 operations/h
1,800 operations/h
100 MΩ min.
2,000 VAC at 50/60 Hz for 1 min.
Insulation resistance
*3
Between coil and contacts
Dielectric
strength
Between contacts of
different polarity
Between contacts of the
same polarity
Vibration
resistance
Shock
resistance
Endurance
Destruction
Malfunction
Destruction
Malfunction
Mechanical
Electrical
*4
2 poles
1,000 VAC at 50/60 Hz for 1 min.
10 to 55 to 10 Hz, 0.5-mm single amplitude (1.0-mm double amplitude)
10 to 55 to 10 Hz, 0.5-mm single amplitude (1.0-mm double amplitude)
1,000 m/s
2
200 m/s
2
50,000,000 operations min. (operating frequency: 18,000 operations/h)
200,000 operations min. (rated load, switching frequency: 1,800 operations/h)
Item
Number of poles
Failure rate P value
(reference value)
*5
Weight
Note:
These are initial values.
*1.
Measurement conditions: 1 A at 5 VDC using the voltage drop method.
100 µA at 1 VDC
*2.
Measurement conditions: With rated operating power applied.
Ambient temperature condition: 23° C
*3.
Measurement conditions: For 500 VDC applied to the same location as for dielectric strength measurement.
Approx. 35 g
*4.
Ambient temperature condition: 23°C
*5.
This value was measured at a switching frequency of 120 operations per minute.
I recently participated in the evaluation of more than a dozen development boards. Along the way, my computer hard drive was full, I was confused about where to find the desktop IDE, I built N develop...
I'm working on a project recently, and the code progress is limited. I hope some experts can help me. Paid is also acceptable. The specific requirements are that the FPGA collects 4 channels of 12-bit...
How to connect a deviceOnce you have a Zigbee device, how do you connect it to the gateway? What are the issues you need to think about? And how to successfully connect it? Here are some summary recor...
IT Home reported on March 30 that digital blogger @数码闲聊站 revealed that Xiaomi and Redmi are developing three engineering machines based on the sm8475 chip, one of which is testing a 50Mp ultra-large ...[Details]
DC/DC Converter Specifications The specification of a board-mounted DC-DC converter is an important and detailed process. When selected correctly, it results in a cost-effective solution that meet...[Details]
Sina Digital News reported on the morning of September 21 that today, the official Weibo account of vivo smart terminal released a poster to cheer for the vivo WATCH smart watch which will be ...[Details]
If you can receive the Asia 3S satellite, you can adjust the azimuth of the satellite antenna and generally you can receive it. The following is a method of adjusting satellite programs collected f...[Details]
AI, artificial intelligence, is a concept full of wisdom and imagination, with a mysterious future. At the same time, it is also a topic that makes people shudder and deeply worried. In fact, ther...[Details]
Simulating highway driving scenes, simulating tunnel scenes with mixed traffic of motor vehicles and non-motor vehicles, simulating extreme weather scenes such as rainy days and heavy fog... The city...[Details]
By establishing a remote monitoring, diagnosis and maintenance center for the automation system, coal mines can achieve the organic integration of the coal mine comprehensive automation platform, the ...[Details]
Indeed, this is a trend that cannot be ignored. With the improvement of hardware processing power and cloud capabilities, the self-learning and intelligent level of speech recognition has advanced by...[Details]
AB Dynamics, a supplier of automotive test systems, has launched a new static driving simulator, the aV DS -S, which brings unprecedented immersion to automotive test drivers and improves its growing...[Details]
Basic Working Principle of Induction Motor
An induction motor is an electric motor that generates torque between the rotor and the stator through induced current. Its basic working principle i...[Details]
illustrate
The Scan Operand for Falling Edges instruction determines whether the signal state of the specified operand ( Operand 1 ) changes from "1" to "0". The instruction compares the curre...[Details]
The microcontroller source program is as follows: #include "mega16.h" #include "1602.h" #include "key.h" float k1,k2; //Record the two numbers of the final input operation uint one,two,three,f...[Details]
GIC is a very important part of ARM architecture. This article is based on the public ARM corresponding data and the MTK development board. I record it after my personal understanding to consolidat...[Details]