Thermal Cutoffs (TCO)
Thermal Cutoffs (TCO)/
Thermal-Links
EYP
Series:
Series:
Series:
Series:
Series:
Series:
N
F
E
H
ML
MU
■
Features
●
Small and Insulation Type
TCO is compact and insulated, featuring quick temperature response, and mountable in a small space without
insulation or protection.
●
High Reliability
TCO opens reliably when the equipment becomes abnormal, and is not resettable.
●
Solid Structure
Unique formed lead provides reliable TCO connection and provides easy assembly handling. (Axial lead type only)
●
Non-Cadomium Alloy
●
Thin Type
Thickness is less than 1 mm. Available for spot welding.(ML and MU series)
■
Approved Safety Standards
●
●
●
●
●
●
(Japan)
: Approved by JET
UL
(U.S.A.)
: E60271
CSA (Canada) : LR67163
VDE (Germany) : 4811. 6-1171-
BEAB (U.K.)
:C
CCC (China)
:
See Ratings in details.
PS
E
■
Recommended Applications
●
Transformers, Solenoids, Ventilation fans, Electric
fans, Small electric motors, Driers, Gas home appliances,
Fluorescent lights, Electric shavers, Adaptors, Heating
devices, ICs, Batteries, etc. The TCO can also be used
for overheating protection.
■
Construction
●
Axial lead type (N, F and E series)
Sealant (Epoxy resin)
Fusible alloy
Fusible alloy
Insulating
Special resin
case(Ceramic)
(Flux)
Special formed
lead wire
(Tin plating copper)
Insulating
case (Ceramic)
Special resin
(Flux)
●
Radial lead type (H series)
●
Thin type (MTand MS series)
Insulating film
Fusible alloy
Sealant
(Epoxy resin)
Special resin
(Flux)
Terminal (Ni)
Lead wire
(Tin plating copper)
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately.
Mar. 2005
Thermal Cutoffs (TCO)
■
Ratings
●
N series
Maximum Temp.
Maximum
Rated
Limit (°C)
½5
Type No. of
Functioning
Holding
Functioning
Operating
½2
½4
Approved
Temp.
Temp.
Temp.
½1
Temp.
½3
UL,VDE,
(°C)
(°C)
Standards
(°C)
(°C)
BEAB
CSA
CCC
52
56
N082
86
82±2
60
60
200
150
45
50
56
60
62
65
N088
92
88±2
200
—
47
52
65
70
75
76
N098
102
98±2
200
150
55
60
76
86
N109
114
110±3
80
90
200
150
65
74
76
86
200
150
80
90
N110
115
110
+3
–2
65
74
90
105
94
105
N124
130
126±2
200
180
80
94
92
108
96
108
N126
133
128±2
200
180
82
96
99
115
103
115
N135
140
136±3
200
180
80
90
105
115
N143
145
141±2
110
120
200
180
80
90
120
130
200
N163
168
163
+4
120
135
–2
90
100
Electrical
Rating
AC/ Amp. Volt.
DC (A)
(V)
AC
AC
DC
AC
AC
DC
AC
AC
DC
AC
AC
DC
AC
AC
DC
AC
AC
DC
AC
AC
DC
AC
AC
DC
AC
AC
DC
AC
AC
DC
3
2
4
3
2
4
3
2
4
3
2
5
3
2
5
3
2
5
3
2
5
3
2
6
3
2
6
3
2
6
125
250
50
125
250
50
125
250
50
125
250
50
125
250
50
125
250
50
125
250
50
125
250
50
125
250
50
125
250
50
PS
E
Approved Safety
Standards
RoHS
UL CSA VDE BEAB CCC
Part No.
EYP2BN082
EYP2BN088
— — — —
— — — —
— — — —
(
Under
)
examination
(
Under
)
examination
EYP2BN098
EYP2BN109
EYP2BN110
EYP2BN124
(
Under
)
examination
(
Under
)
examination
(
Under
)
examination
Under
(
examination
)
EYP2BN126
EYP2BN135
EYP2BN143
EYP2BN163
Note: For long lead types add the letter "L" at the end of the part number.
(Approved Safety Standards File No. UL:E60271, CSA:LR60271, VDE: 4811.6-1171-001, BEAB:C1068, CCC:2002010205004249)
●
F series
Maximum Temp.
Electrical
Approved Safety
Maximum
Rated
Limit (°C)
½5
Rating
Standards
Type No. of
Functioning
Holding
Functioning
Operating
Part No.
Approved
Temp.
½2
Temp.
½4
Temp.
½1
Temp.
½3
UL,VDE,
(°C)
(°C)
Standards
AC/ Amp. Volt.
PS
(°C)
(°C)
UL CSA VDE BEAB CCC
BEAB
CSA
E
DC (A)
(V)
CCC
70
74
AC
2
125
EYP1BF102
75
76
AC
1
250
F102
102
98±2
200
150
55
60
DC 3.5
50
76
90
AC
2
125
EYP1BF115
80
90
200
150
AC
1
250
F115
115
110
+3
–2
70
80
DC
4
50
90
105
AC
2
125
EYP1BF130
F130
130
126±2
200
180
94
105
AC
1
250
74
90
DC 4.5
50
92
108
AC
2
125
EYP1BF133
F133
133
128±2
96
108
200
180
AC
1
250
76
92
DC 4.5
50
99
115
AC
2
125
EYP1BF139
F139
139
135±3
200
180
103
115
AC
1
250
80
95
DC
5
50
120
135
AC
2
125
EYP1BF168
200
F168
168
163
+4
120
142
AC
1
250
–2
95
110
DC
5
50
Note: For long lead types add the letter "L" at the end of the part number.
(Approved Safety Standards File No. UL:E60271, CSA:LR60271, VDE: 4811.6-1171-003, BEAB:C1065, CCC:2002010205004248)
RoHS
(
Under
)
examination
(
Under
)
examination
(
Under
)
examination
(
Under
)
examination
Under
(
examination
)
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately.
Mar. 2005
Thermal Cutoffs (TCO)
●
E series
Maximum Temp.
Maximum
Rated
Limit (°C)
½5
Type No. of
Functioning
Holding
Operating
Functioning
½2
½4
Approved
Temp.
Temp.
Temp.
½1
Temp.
½3
UL,VDE,
(°C)
(°C)
Standards
(°C)
(°C)
BEAB
CSA
CCC
70
78
E102
102
98±2
200
150
75
80
65
70
76
93
E115
115
110±2
80
95
200
150
70
84
90
112
94
112
E130
130
126±2
200
180
83
102
70
81
92
115
96
115
E133
133
128±2
200
180
85
105
99
120
103
120
E139
139
135±2
200
180
92
110
80
90
105
125
E145
145
141±2
200
—
110
125
80
95
Electrical
Rating
AC/ Amp. Volt.
DC (A)
(V)
AC
AC
DC
AC
AC
DC
AC
AC
DC
DC
AC
AC
DC
AC
AC
DC
DC
AC
AC
DC
1.5
0.5
3
1.5
0.5
3
1.5
0.5
3
5
1.5
0.5
3
1.5
0.5
3
5
1.5
0.5
5
125
250
50
125
250
50
125
250
50
50
125
250
50
125
250
50
50
125
250
50
PS
E
Approved Safety
Standards
RoHS
UL CSA VDE BEAB CCC
Part No.
EYP05BE102
(
Under
)
examination
EYP05BE115
EYP05BE130
(
Under
)
examination
(
Under
)
examination
(
Under
)
examination
— — — —
—
—
—
EYP05BE133
EYP05BE139
EYP05BE145
Note: For long lead types add the letter "L" at the end of the part number.
(Approved Safety Standards File No. UL:E60271, CSA:LR60271, VDE: 4811.6-1171-002, BEAB:C1066, CCC:2002010205004246)
●
H series
Maximum Temp.
Maximum
Rated
Limit (°C)
½5
Type No. of
Functioning
Holding
Functioning
Operating
½2
½4
Approved
Temp.
Temp.
Temp.
½1
Temp.
½3
UL,VDE,
(°C)
(°C)
Standards
(°C)
(°C)
BEAB
CSA
CCC
70
74
H102
102
98±2
75
76
200
200
65
70
76
86
H115
115
110±2
80
90
200
200
74
84
90
105
94
105
H130
130
126±2
200
200
86
100
92
108
96
108
H133
133
128±2
200
200
88
102
99
115
H139
139
135±2
200
200
103
115
95
107
120
135
200
200
H168
168
163
+3
120
142
–2
120
135
Electrical
Rating
AC/ Amp. Volt.
DC (A)
(V)
AC
AC
DC
AC
AC
DC
AC
AC
DC
AC
AC
DC
AC
AC
DC
AC
AC
DC
3
2
3.5
3
2
3.5
3
2
3.5
3
2
3.5
3
2
3.5
3
2
3.5
125
250
50
125
250
50
125
250
50
125
250
50
125
250
50
125
250
50
PS
E
Approved Safety
Standards
RoHS
UL CSA VDE BEAB CCC
Part No.
EYP2BH102
(
Under
)
examination
(
Under
)
examination
(
Under
)
examination
(
Under
)
examination
—
EYP2BH115
EYP2BH130
EYP2BH133
EYP2BH139
EYP2BH168
(
Under
)
examination
(Approved Safety Standards File No. UL:E60271, CSA:LR60271, VDE: 4811.6-1171-004, BEAB:C1067, CCC:2002010205004245)
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately.
Mar. 2005
Thermal Cutoffs (TCO)
●
ML series
Part No.
Rated
Maximum
Maximum
Holding
Type No. of
Functioning
Functioning
Operating
Temp.
½2
½4
Temp.
Approved
Temp.
Temp.
½1
Temp.
½3
Limit
(°C)
(°C)
Standards
(°C)
(°C)
(°C)
½5
ML092
—
ML098
—
ML102
—
92
92
98
98
102
102
89±2
89
+3
–4
94±2
94
+3
–2.5
98±2
98
+3
–2.5
55
55
60
60
65
65
60
60
65
65
70
70
135
135
135
135
135
135
Electrical
Rating
AC/
DC
DC
DC
DC
DC
DC
DC
Approved Safety
Standards
RoHS
Volt.
(V)
50
50
50
50
50
50
Under
Under
Under
Application Application Application
Under
Under
Under
Application Application Application
Under
Under
Under
Application Application Application
Amp.
(A)
2
2
2
2
2
2
UL
VDE
CCC
—
EYP2ML092
EYP2ML092U
EYP2ML098
EYP2ML098U
EYP2ML102
EYP2ML102U
—
—
(Approved Safety Standards File No. UL:E60271, VDE: 4811.6-1171-004, CCC:2003010205034615), Last letter "U" of part number means
Pb-free product.
●
MU series
Part No.
Rated
Maximum
Maximum
Type No. of
Functioning
Holding
Functioning
Operating
Temp.
Approved
Temp.
½2
Temp.
½4
Temp.
½1
Temp.
½3
Limit
(°C)
(°C)
Standards
(°C)
(°C)
(°C)
½5
MU092X
92
89±2
55
55
150
Electrical
Rating
AC/
DC
DC
Approved Safety
Standards
RoHS
Volt.
(V)
50
Amp.
(A)
4
UL
VDE
CCC
EYP4MU092X
(
Under
)
examination
(Approved Safety Standards File No. UL:E60271, VDE: 4811.6-1171-009, CCC:2003010205034614)
½1
Rated Functioning Temperature (UL: TF, CSA,VDE, BEAB, CCC: Tf)
The temperature at which a TCO changes its state of conductivity to open circuit with loading detection current only.
PS
Tolerance;
; ±7 °C
E
0
UL,CSA,VDE, BEAB, CCC;
–10
°C
Functioning Temperature (Fusing-off temperature)
The functioning temperature at which a TCO changes its state of conductivity to open circuit in the ambient air oven which increases
temperature by 1 °C per minute and with loading the detective current 0.1 A or less.
Maximum Operating Temperature.
The maximum temperature at which a TCO can be maintained while conducting rated current for 3000 h (N, F, E, H series) or 1000 h (ML, MU
series) For details please refer to specification.
Holding Temperature (UL: TH, CSA: Th, VDE, BEAB, CCC: Tc)
The maximum temperature at which a TCO can be maintained while conducting rated current for 168 h which will not cause a change in
state of conductivity to open circuit.
Maximum Temperature Limit (UL: TM, CSA,VDE, BEAB, CCC: Tm)
The maximum temperature at which a TCO can maintains its mechanical and electrical properties with out closing again for 10
minutes after a TCO has changed its state of conductivity.
½2
½3
½4
½5
■
Dimensions in mm (not to scale)
●
Axial lead type
fD
fd
●
Radial lead type
B
A
C
L
fd
l
L
l
f
D1
Dimensions (mm)
L
N Series
F Series
E Series
9.0±1.0
6.0±1.0
5.0±0.5
fD
2.5±0.2
1.85
+0.20
–0.15
Dimensions (mm)
k
fd
0.60±0.05
0.53±0.02
0.53±0.02
(½) Long lead type
H Series
A
5.0±0.5
B
4.0±0.5
C
2.2±0.3
L
55±3
fd
0.53±0.02
fD1
3 max.
2.2 max.
1.8 max.
38±3 (½78±3)
38±3 (½68±3)
38±3 (½68±3)
1.5±0.1
●
Thin type
F
A
E
G
D
(H)
B
C
Dimensions (mm)
A
ML Series
MU Series
25.0±0.5
26.5±0.5
B
3.2±0.3
4.5±0.4
C
0.65±0.15
1.00±0.15
D
4.5±0.5
11.0
+0.6
–0.4
E
3.0±0.2
3.0±0.2
F
0.10±0.02
0.15±0.02
G
10.25±0.50
7.7±0.5
(H)
(10.25)
(7.7)
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately.
Mar. 2005
Thermal Cutoffs (TCO)
■
Marking
The following items are indicated on TCO.
• N, F, E, H Series : Type No., Date Code, M Mark( ), <PS>E Mark, Rated Functioning Temperature, Rated Current
• ML, MU Series : Type No., Date Code, M Mark( )
■
Packaging Methods
Part No.
EYP2BN
EYP2BN
EYP1BF
EYP1BF
EYP05BE
EYP05BE
EYP2BH
EYP2ML
EYP4MU
L
L
L
Standard Quantity
2000 pcs./Box
2000 pcs./Box
3000 pcs./Box
4000 pcs./Box
4000 pcs./Box
5000 pcs./Box
1500 pcs./Box
2000 pcs./Box
1000 pcs./Box
Bulk
Style
Mass (Weight) [mg/pc.]
340
510
220
330
210
320
350
68
150
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately.
Mar. 2005