PDC500-1024F Overview

DC/DC CONVERTER 24V 500W

PDC500-1024F Parametric

Parameter NameAttribute value
typeisolation
Voltage - Input (minimum)36V
Voltage - input (maximum)75V
Number of outputs1
Voltage - Output 124V
Voltage - Output 2-
Voltage - Output 3-
Voltage - Output 4-
Current - Output (maximum)21A
Power (W)500W
applicationITE (Business)
efficiency75%
Operating temperature0°C ~ 50°C
Installation typerack mount
size/dimensions9.00" long x 5.00" wide x 2.50" high (228.6mm x 127.0mm x 63.5mm)
ApprovalcULus,EN,TUV
PFC500/PDC500 Series Data Sheet
Features
• RoHS lead solder exemption compliant
• Power Factor Correction meets EN61000-3-2 (AC input
versions)
• Fully-regulated outputs
• Remote sense
• Logic level Inhibit
• Current Share, Power Fail, and Power Good Signals
• Overtemperature, overvoltage, and overcurrent protected
• Available with metric or SAE mountings
• Input transient & ESD compliance to
EN61000-4-2/-3/-4/-5
• Fan output voltage and optional fan
• Optional isolation diodes for parallel or redundant
operation
• DC input versions (36-75VDC)
Description
The PFC500/PDC500 products of the PerFormanCe Power Series combine high performance midrange power with
high power density (4.4 watts/in3) and high reliability to meet the requirements of communications, commercial, and
industrial systems.
Providing tightly regulated DC power, the PFC500/PDC500 delivers full output performance with only 300 Linear Feet
per Minute (LFM) forced-air cooling (factory-installed fan optional). Main channel current sharing is provided for
redundant applications, and AC input units can be paralleled with DC input versions. Units are available with SAE
mountings or optional metric mountings.
The PFC500/PDC500 product line is approved to the latest international regulatory standards, and displays the CE
Mark.
Single-Output Model Selection
MODEL
OUTPUT
VOLTAGE
ADJUSTMENT
RANGE
MAXIMUM OUTPUT
CURRENT (NOTE 3)
LINE
REGULATION
LOAD
REGULATION (NOTE 4)
RIPPLE & NOISE
%p-p (NOTE 5)
INITIAL SETTING
ACCURACY
PFC500-1024/PDC500-1024D
24V
(NOTE 1)
21.6V to 26.4V
25.2V to 30.8V
46.0V to 56.0V
21A
17.9A
10.4A
0.5%
0.5%
0.5%
0.2%
0.2%
0.5%
1%
1%
1%
23.88V to 24.12V
27.86V to 28.14V
47.52V to 48.48V
PFC500-1028
(NOTE 2)
PFC500-1048
(NOTE 2)
NOTES:
1)
2)
3)
4)
5)
28V
48V
For AC input, use PFC500 prefix; use PDC500 prefix for DC input versions.
Consult factory for availability of 28V and 48V units with DC input.
Output currents ratings are expressed with 300 LFM forced air.
Remote sense connected. See Application Note #P1 for load regulation when using the D option for 24V units.
Maximum peak to peak noise expressed as a percentage of output voltage, 20 MHz bandwidth.
For ripple/noise on “D” option models, see options data on page 3.
PFC500 Input Specifications
PARAMETER
CONDITIONS/DESCRIPTION
MIN
NOM
MAX
UNITS
Input Voltage - AC
Input Frequency
Brown Out Protection
Hold-Up Time
Input Current
Input Protection
Inrush Surge Current
Power Factor
Operating Frequency
Continuous input range.
AC Input.
Lowest AC input voltage that regulation is maintained with full rated loads.
Over full AC input voltage range at full rated load.
85 VAC at full rated load.
Non-user serviceable internally located AC input line fuse, F10A, 250V.
110 VAC
Internally limited by thermistor, one cycle, 25°C.
220 VAC
85
47
85
20
264
63
7.8
35
65
0.98
100
VAC
Hz
VAC
ms
A
RMS
A
PK
W/VA
kHz
Per EN61000-3-2.
Switching frequency of main transformer.
AUG 01, 2003 revised to JUL 13, 2006
Page 1 of 4
www.power-one.com

PDC500-1024F Related Products

PDC500-1024F PFC500-1048 PFC500-1048FM
Description DC/DC CONVERTER 24V 500W Power Factor Controller, 10.4A, 100kHz Switching Freq-Max, PACKAGE-9 AC-DC Regulated Power Supply Module, 500W
Maker - Bel Bel
Reach Compliance Code - unknown compliant
Other features - ALSO OPERATES IN ADJUSTABLE MODE FROM 46 V TO 56 V REMOTE SHUTDOWN
Analog Integrated Circuits - Other Types - POWER FACTOR CONTROLLER AC-DC REGULATED POWER SUPPLY MODULE
Certification - UL, CSA, TUV CSA, TUV, UL
Efficiency (main output) - 75% 75%
high - 63.5 mm 63.5 mm
Maximum input voltage - 264 V 264 V
Minimum input voltage - 85 V 85 V
length - 228.6 mm 266.7 mm
Maximum grid adjustment rate - 0.5% 0.5%
Maximum load regulation - 0.5% 0.5%
Maximum operating temperature - 50 °C 50 °C
Maximum output current - 10.4 A 10.4 A
Nominal output voltage - 48 V 48 V
Protect - OUTPUT OVER CURRENT; OUTPUT OVER VOLTAGE; THERMAL OUTPUT OVER CURRENT; OUTPUT OVER VOLTAGE; THERMAL
Maximum total power output - 500 W 500 W
width - 127 mm 127 mm
Internet of Things For Dummies 2nd Edition
The Internet of Things (IoT) is creating a new world, a quantifiable and measurable world. In this world, people can better manage their lives, cities can better manage their infrastructure, and compa...
石榴姐 RF/Wirelessly
RISC-V RVB2601 First Experience
1. The development board comes with a JLINK simulation interface, which only requires a USB cable for easy download and debugging 2. The W800 module has no antenna, so I equipped it with an FPC antenn...
qq4988 XuanTie RISC-V Activity Zone
What voltage is suitable for TL431?
Now design an analog circuit with 12V and 5V voltages. The circuit needs a 2.5V reference source, and TL431 is used as the reference source. The problem is that 12V and 5V seem to be OK, and 5V is con...
bigbat Analog electronics
How to keep the voice chip stable for a long time?
High-quality voice chips usually have clear sound quality, long storage time, large sound coverage area, built-in storage voice recognition MP3 high-quality audio single/loop playback, and the sound e...
九芯语音ic Domestic Chip Exchange
Importing an old MPLAB IDE V8.9 project into MPLAB X IDE shows 'other' has different root
I previously used MPLAB IDE V8.9 to create a project using assembly. The project can run normally and contains only one assembly file and one header file. I want to use MPLAB X IDE V5.45 to convert. W...
LB2019 Microchip MCU
[Smartwatch for environmental experts] Part 8: Code migration for personnel going down the mine
1. Introduction Originally, this article was going to write about activity status recognition, but there were some problems with the code for the personnel going down the mine, so I did a code migrati...
w494143467 onsemi and Avnet IoT Innovation Design Competition

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号