T-1 3/4 (5 mm)
SOLID STATE LAMPS
HIGH EFF. RED
HIGH EFF. RED
HLMP-3300
HLMP-3301
HIGH EFF. RED
HIGH EFF. RED
STANDARD RED
FEATURES
• Popular, general purpose lamps
• Wide and narrow viewing angle devices for direct
view or backlighting
C
L
HLMP-3315
HLMP-3316
FLV110
PACKAGE DIMENSIONS
• Solid state reliability
• Sturdy leads for easy assembly
0.200 (5.08)
0.180 (4.57)
0.040 (1.02)
SEE
NOTES
DESCRIPTION
The HLMP-33XX series consists of high efficiency red T-1 3/4
lamps with a viewing angle of 35° or 65°. FLV110 is a low profile
standard red T-1 3/4 lamp with a diffused lens, providing a
viewing angle of 70°.
NOTES:
1. ALL DIMENSIONS ARE IN INCHES (mm).
0.050 (1.27)
0.100 (2.54)
Ø 0.230 (5.84)
0.050 (1.27)
REF.
0.100 (2.54)
REF.
1.00 (25.4)
MIN
2. TOLERANCES ARE ±.010” INCH UNLESS SPECIFIED.
3. AN EPOXY MENISCUS MAY EXTEND ABOUT .040”
(1 mm) DOWN THE LEADS.
4. DIMENSIONS X.
PACKAGE HEIGHT HLMP = .330 (8.38)/.350 (8.89)
FLV = .275 (6.98)/.295 (7.49)
5. FLV FLANGE HEIGHT = 0.040 (1.02)
0.060 (1.53)
0.023 (0.58)
0.017 (0.43)
SQ. TYP. (2X)
FLAT DENOTES
CATHODE
ABSOLUTE MAXIMUM RATING
Parameter
Power Dissipation
Average Forward Current
Peak Forward Current
(T
A
=25°C)
HLMP33XX
135
30
90
5
5
-55 to +100
-55 to +100
FLV110
135
30
90
5
5
-55 to +100
-55 to +100
UNITS
mW
mA
mA
V
sec
°C
°C
(1
µS
pulsewidth, 0.3% duty cycle)(FLV110 1 amp)
Reverse Voltage
Lead Soldering Time at 260° C
Operating Temperature
Storage Temperature
2001 Fairchild Semiconductor Corporation
DS300005
2/27/01
1 OF 4
www.fairchildsemi.com
T-1 3/4 (5 mm)
SOLID STATE LAMPS
ELECTRICAL / OPTICAL CHARACTERISTICS
Part Number
Luminous Intensity (mcd)
Minimum
Typical
Forward Voltage (V)
Maximum
Typical
Peak Wavelength (nm)
Reverse Voltage (V)
Viewing Angle (°)
* For FLV110 Test I
F
= 20mA
3.0
2.2
635
5
65
3.0
2.2
635
5
65
3.0
2.2
635
5
35
3.0
2.2
635
5
35
2.0
1.6
660
5
70
I
F
= 10mA
I
R
= 100µA
I
F
= 10mA
2.0
3.5
4.0
7.0
12
18
20
35
0.8*
3.0*
I
F
= 10mA
HLMP-3300
(T
A
=25°C)
HLMP-3315
HLMP-3316
FLV110
Condition
I
F
= 10mA
HLMP-3301
www.fairchildsemi.com
2 OF 4
2/27/01
DS300005
T-1 3/4 (5 mm)
SOLID STATE LAMPS
TYPICAL PERFORMANCE CURVES
(T
A
=25°C)
90
2.5
RELATIVE LUMNOUS INTENSITY
(NORMALIZED AT 20 mA)
80
AlGaAs
RED
I
F
- FORWARD CURRENT (mA)
70
60
50
40
30
20
10
0
1.0
2.0
3.0
4.0
5.0
HER
2.0
1.5
HER
1.0
AlGaAs
RED
0.5
0.0
0
5
10
15
20
25
30
V
F
- FORWARD VOLTAGE (V)
I
F
- DC FORWARD CURRENT (mA)
Fig. 1 Forward Current vs. Forward Voltage
Fig. 2 Relative Luminous Intensity vs.
DC Forward Current
50
1.0
AlGaAs RED
I
F
- FORWARD CURRENT (mA)
40
RELATIVE INTENSITY
HER, AlGaAs RED
30
0.5
20
HER
10
0
500
550
600
650
700
750
0
0
20
40
60
85
100
WAVELENGTH (nm)
T
A
- AMBIENT TEMPERATURE (˚C)
Fig. 3 Relative Intensity vs. Peak Wavelength
Fig. 4 Current Derating Curve
DS300005
2/27/01
3 OF 4
www.fairchildsemi.com
T-1 3/4 (5 mm)
SOLID STATE LAMPS
DISCLAIMER
FAIRCHILD SEMICONDUCTOR RESERVES THE THE RIGHT TO MAKE CHANGES WITHOUT FURTHER NOTICE
TO ANY PRODUCTS HEREIN TO IMPROVE RELIABILITY, FUNCTION OR DESIGN. FAIRCHILD DOES NOT
ASSUME ANY LIABILITY ARISING OUT OF THE APPLICATION OR USE OF ANY PRODUCT OR CIRCUIT
DESCRIBED HEREIN; NEITHER DOES IT CONVEY ANY LICENSE UNDER ITS PATENT RIGHTS, NOR THE
RIGHTS OF OTHERS.
LIFE SUPPORT POLICY
FAIRCHILD’S PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT
DEVICES OR SYSTEMS WITHOUT THE EXPRESS WRITTEN APPROVAL OF THE PRESIDENT OF FAIRCHILD
SEMICONDUCTOR CORPORATION. As used herein:
1. Life support devices or systems are devices or
systems which, (a) are intended for surgical
implant into the body,or (b) support or sustain life,
and (c) whose failure to perform when properly
used in accordance with instructions for use provided
in labeling, can be reasonably expected to result in a
significant injury of the user.
2. A critical component in any component of a life support
device or system whose failure to perform can be
reasonably expected to cause the failure of the life
support device or system, or to affect its safety or
effectiveness.
www.fairchildsemi.com
4 OF 4
2/27/01
DS300005