New Product
Digital Temperature Controller
E5@C/E5@C-T
E5@C Series That Pursues Greater Visibility with Large White PV Display.
Models with Push-In Plus Terminal Blocks That Reduce Wiring Work, DIN
Track-mounting Models That Are Ideal for Connecting to PLCs, Plug-in
Models That Are Convenient for Maintenance, and Programmable Models for
a Wider Range of Application. A Wide Lineup of Models to Meet a Wide
Range of User Needs.
Digital Temperature Controllers: E5@C Series
48 × 24 mm
Models with Screw Terminal Blocks/
Models with Screwless Clamp
Terminal Blocks
Models with Screw Terminal Blocks
E5GC
page 2
E5CC
page 18
48 × 48 mm
Models with Push-In Plus Terminal Blocks
E5CC-B
page 18
Plug-in Models
E5CC-U
page 18
Models with Screw Terminal Blocks
48 × 96 mm
Models with Push-In Plus Terminal Blocks
E5EC
page 40
E5EC-B
page 40
96 × 96 mm
DIN 22.5-mm-wide
Controllers That
Mount to DIN Track
Models with Screw Terminal Blocks
E5AC
page 40
Models with Screw Terminal Blocks
E5DC
page 58
Programmable Digital Temperature Controllers: E5@C-T Series
48 × 48 mm
Models with Screw Terminal Blocks
E5CC-T
page 74
48 × 96 mm
Models with Screw Terminal Blocks
E5EC-T
page 92
96 × 96 mm
Models with Screw Terminal Blocks
E5AC-T
page 92
1
Digital Temperature Controller
E5GC
(48
×
24 mm)
Easy Operation and High Performance of
the E5@C Series in a Compact 48
×
24-
mm Body
• A compact body of 48
×
24
×
90 mm (W
×
H
×
D) that is ideal for
small equipment, laboratory instruments, and others.
• White PV display with a height of 10.5 mm for high visibility even
with the compact body.
• Removable terminal block to simplify maintenance. Select from
screw terminal blocks or screwless clamp terminal blocks for the
wiring method.
• High-speed sampling at 50 ms.
• Easy connections to a PLC with programless communications.
• Set up the Controller without wiring the power supply by
connecting to the computer with a Communications Conversion
Cable (sold separately). Setup is easy with the CX-Thermo (sold
separately).
48
×
24 mm
Models with Screw
Terminal Blocks
E5GC-@6
48
×
24 mm
Models with Screwless
Clamp Terminal Blocks
E5GC-@C
Refer to your OMRON website for the most recent
information on applicable safety standards.
Refer to
Safety Precautions
on 118.
Main I/O Functions
Sensor Input
Universal input
•
Thermocouple
•
Pt
•
Analog current/voltage
Indication Accuracy
•
Thermocouple input:
±0.3%
of PV
•
Pt input:
±0.2%
of PV
•
Analog input:
±0.2%
of FS
Sampling Period
•
50 ms
E5GC
Dual displays: PV/SV
4-digit displays
Control Output 1
• Relay output
• Voltage output (for driving SSR)
• Linear current output
Auxiliary Outputs
• None
•1
•2
Event Inputs
• None
•1
•2
Serial Communications
• None
• RS-485
• PF (shift) Key
• Temperature status display
• Simple programming
• Independent heating and
cooling PID control
• Changed parameter display
• Display brightness setting
• Simple transfer output (only on
models with liner current outputs)
• Work Bit Message
This datasheet is provided as a guideline for selecting products.
Be sure to refer to the following manuals for application precautions and other information required for operation before attempting
to use the product.
E5@C Digital Temperature Controllers User’s Manual (Cat. No. H174)
E5@C Digital Temperature Controllers Communications Manual (Cat. No. H175)
2
E5GC
Model Number Legend and Standard Models
Model Number Legend
E5GC-@@
@ @ @
M-@@@ (Example: E5GC-RX1A6M-015)
−− − − − − −−−
A
B C D E
F
A
B
No. of
Model Control
outputs 1 auxiliary
and 2
outputs
E5GC
RX
QX
*1
CX
*2
0
1
2
A
D
6
C
M
000
015
016
023
024
C
Power
supply
voltage
D
Terminal
type
E
Input
type
F
Options
Meaning
48
×
24 mm
Control output 1
Relay output
Voltage output
(for driving SSR)
Linear current output
Control output 2
None
None
None
*3
*3, *4
*5
None
1
2
100 to 240 VAC
24 VAC/DC
Screw terminal blocks (with cover)
Screwless clamp terminal blocks
*6
Universal input
HB alarm and HS alarm
Communications Event inputs
---
---
---
---
RS-485
---
---
---
1
1
---
---
---
---
2
*1.
The control output can be used as a simple transfer output.
*2.
Only option 000 can be selected if an auxiliary output is zero.
*3.
Option 016 and 023 can be selected only if two auxiliary outputs are selected.
*4.
Option with HB and HS alarms (023) cannot be selected if a linear current output is selected for the control output.
*5.
Option 024 can be selected only if one auxiliary output is selected.
*6.
The specifications are different for Temperature Controllers with Push-In Plus terminal blocks. Refer to
Precautions when Wiring
on page 124.
Heating and Cooling Control
Using Heating and Cooling Control
A
Control Output Assignment
An auxiliary output is used as the cooling control output.
B
Control
If PID control is used, you can set PID control separately for heating and cooling.
This allows you to handle control systems with different heating and cooling response characteristics.
3
E5GC
Optional Products (Order Separately)
USB-Serial Conversion Cable
Model
E58-CIFQ2
Waterproof Packing
Model
Y92S-P12
Note:
This Waterproof Packing is provided with the Digital
Temperature Controller.
Communications Conversion Cable
Model
E58-CIFQ2-E
Note:
Always use this product together with the E58-CIFQ2.
This Cable is used to connect to the bottom-panel Setup Tool
port.
Draw-out Jig
Model
Y92F-55
Current Transformers (CTs)
Hole diameter
5.8 mm
5.8 mm
12.0 mm
12.0 mm
Model
E54-CT1
E54-CT1L*
E54-CT3
E54-CT3L*
CX-Thermo Support Software
Model
EST2-2C-MV4
Note:
CX-Thermo version 4.62 or higher is required for the E5GC.
For the system requirements for the CX-Thermo, refer to
information on the EST2-2C-MV4 on the OMRON website
(www.ia.omron.com).
*Lead
wires are included with these CTs. If UL certification is required, use
these CTs.
Mounting Adapter
Model
Y92F-53 (2pcs)
Note:
This Mounting Adapter is provided with the Digital Temperature
Controller.
4
E5GC
Specifications
Ratings
Power supply voltage
Operating voltage range
Power consumption
A in model number: 100 to 240 VAC, 50/60 Hz
D in model number: 24 VAC, 50/60 Hz; 24 VDC
85 to 110% of rated supply voltage
5.9 VA max. at 100 to 240 VAC, and 3.2 VA max. at 24 VAC or 1.8 W max. at 24 VDC
Temperature input
Thermocouple: K, J, T, E, L, U, N, R, S, B, C/W, or PL II
Platinum resistance thermometer: Pt100 or JPt100
Infrared temperature sensor (ES1B): 10 to 70°C, 60 to 120°C, 115 to 165°C, or 140 to 260°C
Analog input
Current input: 4 to 20 mA or 0 to 20 mA
Voltage input: 1 to 5 V, 0 to 5 V, or 0 to 10 V
Current input: 150
Ω
max., Voltage input: 1 MΩ min.
(Use a 1:1 connection when connecting the ES2-HB-N/THB-N.)
ON/OFF control or 2-PID control (with auto-tuning)
SPST-NO, 250 VAC, 2 A (resistive load), electrical life: 100,000 operations, minimum applicable load: 5
V, 10 mA (reference value)
Output voltage 12 VDC
±20%
(PNP), max. Load current: 21 mA, with short-circuit protection circuit
4 to 20 mA DC/0 to 20 mA DC, load: 500
Ω
max., resolution: Approx. 10,000
1 or 2 (depends on model)
SPST-NO relay outputs, 250 VAC, 2 A (resistive load),
Electrical life: 100,000 operations, Minimum applicable load: 10 mA at 5 V (reference value)
1 or 2 (depends on model)
Contact input ON: 1 kΩ max., OFF: 100 kΩ min.
Non-contact input ON: Residual voltage 1.5 V max.; OFF: Leakage current 0.1 mA max.
Current flow: approx. 7 mA per contact
Digital setting using front panel keys
11-segment digital displays and individual indicators
Character height: PV: 10.5 mm, SV: 5.0 mm
Up to eight set points (SP0 to SP7) can be saved and selected using the event inputs, key operations, or
serial communications.
*
None
Manual output, heating/cooling control, loop burnout alarm, SP ramp, other alarm functions, heater
burnout (HB) alarm (including SSR failure (HS) alarm), 40% AT, 100% AT, MV limiter, input digital filter,
self tuning, robust tuning, PV input shift, run/stop, protection functions, extraction of square root, MV
change rate limit, logic operations, temperature status display, simple programming, moving average of
input value, display brightness setting, simple transfer output, and work bit message
−10
to 55°C (with no condensation or icing), For 3-year warranty:
−10
to 50°C with standard mounting (with
no condensation or icing)
25 to 85%
−25
to 65°C (with no condensation or icing)
2,000 m max.
T2A, 250 VAC, time-lag, low-breaking capacity
Overvoltage category II, Pollution Degree 2 (EN/IEC/UL 61010-1)
Sensor input
Input impedance
Control method
Relay output
Control
output
Voltage output
(for driving SSR)
Linear current output
Number of outputs
Output specifications
Number of inputs
Event
input
External contact input
specifications
Auxiliary
output
Setting method
Indication method
Multi SP
Bank switching
Other functions
Ambient operating temperature
Ambient operating humidity
Storage temperature
Altitude
Recommended fuse
Installation environment
*
There are up to four event inputs.
5