Disc Ceramic Capacitors
Safety Ceramic Capacitors
DEFINITIONS (IEC 384-14 1993)
X FUNCTION:
applications where the capacitor failure
does not lead to danger of electrical shock. There are
three subclasses related to the peak voltage of the
impulses superimposed to the mains voltage:
Subclass X1: impulses up to 4000V
Subclass X2: impulses up to 2500V
Subclass X3: impulses up to 1200V
Y FUNCTION:
applications where the capacitor failure
may lead to danger of electrical shock. There are four
subclasses related to the peak voltage of the impulses
applied before the life test:
Subclass Y1: impulses up to 8000V
Subclass Y2: impulses up to 5000V
Subclass Y3: rated 250Vac without impulses
Subclass Y4: impulses up to 2500V
ANTENNA:
the capacitors are used to decouple the
antenna leads of video and audio equipment, whose
failure may lead to danger of electrical shock.
TPC Safety Capacitors:
61V (GZO): meets subclasses X1, Y1 Test voltage 4000 VAC
62O (GKO): meets subclasses X1, Y2 Test voltage 2500 VAC
65N (GAY): meets subclasses X2, Y3 Test voltage 1800 VAC
HOW TO ORDER
61
Product Code
V
Voltage
101
Capacitance
K
Tolerance
B
Lead
Forming
D
Capacitor
Diameter
C
Finishing
A
Packaging
PERFORMANCE CHARACTERISTICS
61V
Measured at
Capacitance Tolerance
D.F max. @ 25ºC
Insulation Resistance (IR)
Test Voltage Between Leads*
Test Voltage Leads to Body
Operating Temperature Range (ºC)
* Main reference voltage
62O
1.0 kHz / 0.3 Vrms / 25ºC
±20% / -20 +50%
1.5%
≥
10 GΩ
2.500 VAC
2.500 VAC
-40 +125
65N
1.0 kHz / 0.3 Vrms / 25ºC
±20% / -20 +50%
1.5%
≥
10 GΩ
1.800 VAC
1.800 VAC
-40 +125
1.0 kHz / 0.3 Vrms / 25ºC
±20% / -20 +50%
1.5%
≥
10 GΩ
4.000 VAC
4.000 VAC
-40 +125
CERTIFICATION BODY APPROVALS
Standard
UL
UL 1414
DIN BDE 0560
Part 2
DIN EN 132400: 1995
IEC 384-14: 1993
IMQ
EN 132400: 1994
IEC 384-14: 1993
Certificate
Number
E 147842 (N)
LR 100430-2
–
94612
94610
94634
V4551
61V
Rated
Voltage
250 VAC
250 VAC
–
X1: 400 VAC
Y1: 250 VAC
X1: 400 VAC
Y1: 250 VAC
Climatic
Category
Certificate
Number
E 147842 (N)
LR 100430-1
76830
76804
62O
Rated
Voltage
250 VAC
250 VAC
400 VAC
X1: 400 VAC
Y1: 250 VAC
X1: 400 VAC
Y2: 250 VAC
Climatic
Category
Certificate
Number
E 147842 (N)
–
65N
Rated
Voltage
250 VAC
–
–
–
–
Climatic
Category
–
–
–
–
–
CAS CAN/CSA - C22.2 No. 1-94
25/85/21
40/85/21/C
40/125/21C
–
–
–
VDE
40/85/21/C
101384
40/125/21/C
V4635
17
Disc Ceramic Capacitors
Safety Ceramic Capacitors Epoxy Coated
APPROVED LOGOS
CSA
IMQ
UL
VDE
TYPICAL APPLICATION FOR SAFETY CERAMIC DISCS AND SWITCH MODE
Across the line capacitors for noise suppression
Line by-pass for noise suppression
Cy
Cy
Cx
Cx=TPC 61V or 62O series
Cx
Cy
Cy=TPC 61V or 62O series
Cy
Typical X and Y function application
Protection and suppression of a motor
(X and Y function)
Chassis
Y Function
Cy
Cy
Cx
Cx
Cy
M
Y Function
Capacitor
61V or 62O series
R
X Function
S
19