DC/DC CONVERTER 48V 182W
Parameter Name | Attribute value |
type | closed |
Voltage - Input (minimum) | 43V |
Voltage - input (maximum) | 160V |
Number of outputs | 1 |
Voltage - Output 1 | 48V |
Voltage - Output 2 | - |
Voltage - Output 3 | - |
Voltage - Output 4 | - |
Current - Output (maximum) | 3.8A |
Power (W) | 182W |
Voltage - Isolation | 2.25kV |
application | Hazardous Locations, ITE (Commercial), Railway |
efficiency | 89% |
Operating temperature | -40°C ~ 105°C |
Installation type | Base installation |
size/dimensions | 4.06" long x 3.50" wide x 3.45" high (103.1mm x 88.9mm x 87.6mm) |
Approval | CB,cULus,cURus |
TEQ 160-7218WIR | TEQ 160-7212WIR | TEQ 160-7215WIR | TEQ 160-7216WIR | TEQ 160-4812WIR | TEQ 160-4815WIR | TEQ 160-4816WIR | TEQ 160-4818WIR | |
---|---|---|---|---|---|---|---|---|
Description | DC/DC CONVERTER 48V 182W | DC/DC CONVERTER 12V 180W | DC/DC CONVERTER 24V 180W | DC/DC CONVERTER 28V 182W | DC/DC CONVERTER 12V 156W | DC/DC CONVERTER 24V 156W | DC/DC CONVERTER 28V 154W | DC/DC CONVERTER 48V 154W |
type | closed | closed | closed | closed | closed | closed | closed | closed |
Voltage - Input (minimum) | 43V | 43V | 43V | 43V | 19V | 19V | 19V | 19V |
Voltage - input (maximum) | 160V | 160V | 160V | 160V | 75V | 75V | 75V | 75V |
Number of outputs | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 |
Voltage - Output 1 | 48V | 12V | 24V | 28V | 12V | 24V | 28V | 48V |
Current - Output (maximum) | 3.8A | 15A | 7.5A | 6.5A | 13A | 6.5A | 5.5A | 3.2A |
Power (W) | 182W | 180W | 180W | 182W | 156W | 156W | 154W | 154W |
Voltage - Isolation | 2.25kV | 2.25kV | 2.25kV | 2.25kV | 2.25kV | 2.25kV | 2.25kV | 2.25kV |
application | Hazardous Locations, ITE (Commercial), Railway | Hazardous Locations, ITE (Commercial), Railway | Hazardous Locations, ITE (Commercial), Railway | Hazardous Locations, ITE (Commercial), Railway | Hazardous Locations, ITE (Commercial), Railway | Hazardous Locations, ITE (Commercial), Railway | Hazardous Locations, ITE (Commercial), Railway | Hazardous Locations, ITE (Commercial), Railway |
efficiency | 89% | 89% | 89% | 89% | 90% | 90% | 90% | 90% |
Operating temperature | -40°C ~ 105°C | -40°C ~ 105°C | -40°C ~ 105°C | -40°C ~ 105°C | -40°C ~ 105°C | -40°C ~ 105°C | -40°C ~ 105°C | -40°C ~ 105°C |
Installation type | Base installation | Base installation | Base installation | Base installation | Base installation | Base installation | Base installation | Base installation |
size/dimensions | 4.06" long x 3.50" wide x 3.45" high (103.1mm x 88.9mm x 87.6mm) | 4.06" long x 3.50" wide x 3.45" high (103.1mm x 88.9mm x 87.6mm) | 4.06" long x 3.50" wide x 3.45" high (103.1mm x 88.9mm x 87.6mm) | 4.06" long x 3.50" wide x 3.45" high (103.1mm x 88.9mm x 87.6mm) | 4.06" long x 3.50" wide x 3.45" high (103.1mm x 88.9mm x 87.6mm) | 4.06" long x 3.50" wide x 3.45" high (103.1mm x 88.9mm x 87.6mm) | 4.06" long x 3.50" wide x 3.45" high (103.1mm x 88.9mm x 87.6mm) | 4.06" long x 3.50" wide x 3.45" high (103.1mm x 88.9mm x 87.6mm) |
Approval | CB,cULus,cURus | CB,cULus,cURus | CB,cULus,cURus | CB,cULus,cURus | CB,cULus,cURus | CB,cULus,cURus | CB,cULus,cURus | CB,cULus,cURus |