EEWORLDEEWORLDEEWORLD

Part Number

Search

GB30S48K01

Description
MEDICAL & ITE, SWITCHING INTERNA
CategoryPower/power management   
File Size14MB,4 Pages
ManufacturerSL Power
Environmental Compliance
Download Datasheet Parametric Compare View All

GB30S48K01 Online Shopping

Suppliers Part Number Price MOQ In stock  
GB30S48K01 - - View Buy Now

GB30S48K01 Overview

MEDICAL & ITE, SWITCHING INTERNA

GB30S48K01 Parametric

Parameter NameAttribute value
typeopen framework
Number of outputs1
Voltage - input100 ~ 240 VAC
Voltage - Output 148V
Voltage - Output 2-
Voltage - Output 3-
Voltage - Output 4-
Current - Output (maximum)630mA
Power (W)30W
applicationITE (Business), Medical
Voltage - Isolation4kV
efficiency88%
Operating temperature-25°C ~ 70°C (with derating)
characteristicuniversal input
Installation typeBase installation
size/dimensions4.00" long x 1.90" wide x 1.00" high (101.6mm x 48.3mm x 25.4mm)
Minimum load requirednone
ApprovalCE,cURus,UL
GB30 Family
Medical
30W Single Output
Medical & Industrial Grade
FEATURES AND BENEFITS
30W Open Frame and PCB-mount Power Supply
1.9” x 4.0” x 1.0” Package
Test &
Measurement
Approved to CSA/EN/IEC/UL60601-1, 3
rd
Edition
E-cap Life of >8 Years
>1,000,000 Hours MTBF
3 Year Warranty
Meets Class B Radiated & Conducted EMI, with
Margin
Universal Input 90-264VAC
<0.1W No Load Input Power
Approved to CSA/EN/IEC/UL62368-1
Industrial
Meets Heavy Industrial and IEC60601-1-2
4
th
Edition Levels of EMC
Note:
*Consult Factory for compliance information.
MODEL SELECTION
Model Number
2
GB30S05K01
GB30S07K01
GB30S09K01
GB30S12K01
GB30S15K01
GB30S24K01
GB30S48K01
Volts
5.0V
7.5V
9.0V
12.0V
15.0V
24.0V
48.0V
Rated
Current
4.0A
3.0A
3.0A
2.5A
2.0A
1.33A
0.63A
Output
Power
20W
22.5W
27W
30W
30W
30W
30W
Ripple &
Noise
1
75mV pk-pk
75mV pk-pk
90mV pk-pk
120mV pk-pk
120mV pk-pk
240mV pk-pk
480mV pk-pk
Line
Regulation
±1%
±1%
±1%
±1%
±1%
±1%
±1%
Load
Regulation
±2%
±2%
±2%
±2%
±2%
±2%
±2%
Input
Class/Termination
Class I (Grounded) input,
3-pin AMP/Molex type
connector
Change “K” to “C” for
class II input
Change “K” to “P” for PCB
mount pins, class I input
Change “K” to “PCB mount
pins”, class II input
Output
Termination
4-pin AMP/Molex type
connector for “K” and “C”
versions
PCB mount pins for
“P” and “V” versions
Note:
1. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uF & 47uF parallel capacitor.
2. Other output voltages available, consult factory.
3. All specifications are typical at 230VAC, full load, at 25°C ambient unless noted.
INPUT
Input Voltage and
Frequency
Input Current
Inrush Current
Input Fuses
Earth Leakage Current
(Input to Ground)
Earth Leakage Current
(Output to Ground)
Efficiency
Power Factor
100-240VAC, ±10%, 47-63Hz, 1Ø
115VAC: 1.2A, 230VAC: 0.6A
264VAC, cold start: will not exceed 40A peak
3.15A, 250VAC fuse in both line and neutral
<500μA@264VAC, 60Hz, NC
<1mA@264VAC, 60Hz, SFC
<100μA@264VAC, 60Hz, NC
<500μA@264VAC, 60Hz, SFC
>88%, typical
0.9, min., 230VAC, 80-100% load vector, 25°C
ambient
OUTPUT
Turn On Time
Hold-Up Time
Output Power
Output Voltage
<700ms
20ms/100VAC at full load
20W-30W continuous – See models chart for specific
voltage model ratings
See models chart
500μs
resp. time for return to w/in 0.5% of final value
for any 50% load step from 5% to 100% of rated load,
∆i/∆t<0.2A/μs
Max voltage deviation is +/-3.5%
+/-2%
Transient Response
Regulation
Note:
All specifications are typical at 230VAC input, full load, at 25°C ambient unless noted.
Note:
All specifications are typical at 230VAC input, full load, at 25°C ambient unless noted.
GB30 Datasheet v0818
Copyright © 2018 SL Power Electronics Corp. - All rights reserved.
Page 1

GB30S48K01 Related Products

GB30S48K01 GB30S05K01 GB30S07K01 GB30S09K01 GB30S12K01 GB30S15K01 GB30S24K01
Description MEDICAL & ITE, SWITCHING INTERNA MEDICAL & ITE, SWITCHING INTERNA MEDICAL & ITE, SWITCHING INTERNA MEDICAL & ITE, SWITCHING INTERNA MEDICAL & ITE, SWITCHING INTERNA MEDICAL & ITE, SWITCHING INTERNA MEDICAL & ITE, SWITCHING INTERNA
type open framework open framework open framework open framework open framework open framework open framework
Number of outputs 1 1 1 1 1 1 1
Voltage - input 100 ~ 240 VAC 100 ~ 240 VAC 100 ~ 240 VAC 100 ~ 240 VAC 100 ~ 240 VAC 100 ~ 240 VAC 100 ~ 240 VAC
Voltage - Output 1 48V 5V 7.5V 9V 12V 15V 24V
Current - Output (maximum) 630mA 4A 3A 3A 2.5A 2A 1.33A
Power (W) 30W 20W 23W 27W 30W 30W 32W
application ITE (Business), Medical ITE (Business), Medical ITE (Business), Medical ITE (Business), Medical ITE (Business), Medical ITE (Business), Medical ITE (Business), Medical
Voltage - Isolation 4kV 4kV 4kV 4kV 4kV 4kV 4kV
efficiency 88% 88% 88% 88% 88% 88% 88%
Operating temperature -25°C ~ 70°C (with derating) -25°C ~ 70°C (with derating) -25°C ~ 70°C (with derating) -25°C ~ 70°C (with derating) -25°C ~ 70°C (with derating) -25°C ~ 70°C (with derating) -25°C ~ 70°C (with derating)
characteristic universal input universal input universal input universal input universal input universal input universal input
Installation type Base installation Base installation Base installation Base installation Base installation Base installation Base installation
size/dimensions 4.00" long x 1.90" wide x 1.00" high (101.6mm x 48.3mm x 25.4mm) 4.00" long x 1.90" wide x 1.00" high (101.6mm x 48.3mm x 25.4mm) 4.00" long x 1.90" wide x 1.00" high (101.6mm x 48.3mm x 25.4mm) 4.00" long x 1.90" wide x 1.00" high (101.6mm x 48.3mm x 25.4mm) 4.00" long x 1.90" wide x 1.00" high (101.6mm x 48.3mm x 25.4mm) 4.00" long x 1.90" wide x 1.00" high (101.6mm x 48.3mm x 25.4mm) 4.00" long x 1.90" wide x 1.00" high (101.6mm x 48.3mm x 25.4mm)
Minimum load required none none none none none none none
Approval CE,cURus,UL CE,cURus,UL CE,cURus,UL CE,cURus,UL CE,cURus,UL CE,cURus,UL CE,cURus,UL
To prevent smog, don’t use this weird “Japanese portable air purifier”!
[align=left][font=微软雅黑][size=4]When it comes to haze days, we all know to turn on the air purifier at home and wear a mask when going out. As everyone pays more attention to preventing haze, related a...
eric_wang Talking
【Featured Q&A】Battery protection and fuel gauge design
In battery pack design, battery safety, battery life, battery life, fast charging, etc. are important design considerations. Currently, the battery pack design solutions provided by TI can be applied ...
qwqwqw2088 Analogue and Mixed Signal
First transceiver to support all open source smart home protocols simultaneously
On January 16, 2020, Qorvo launched the breakthrough IoT transceiver Qorvo QPG7015M. The transceiver is said to support all low-power open-source standard smart home technologies to operate simultaneo...
alan000345 RF/Wirelessly
Please recommend a single op amp to implement a second-order or higher-order high-gain (32dB) active low-pass filter solution
[i=s]This post was last edited by 向阳xl on 2019-11-27 15:24[/i]Origin of the problem: In order to simplify the circuit and reduce costs, it is hoped to realize an active second-order low-pass filter po...
向阳xl Analog electronics
RSL10 Family Portrait
...
dql2016 onsemi and Avnet IoT Innovation Design Competition
Ways to reduce belly fat
Fat loss method 1: control diet Your belly could not have been formed naturally. It could only be caused by your bad living and eating habits. So the first thing you should do is to change your bad ea...
led2015 Talking

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号