WSL 600 SERIES, 60 WATTS
L-CASE
HIGH EFFICIENCY, COMPACT DESIGN SWITCHMODE TECHNOLOGY
UL, cUL, TUV Certified CE marked for European Compliance CEC /
DOE EISA 2007 Compliant
CF Version in UL File 3
rd
Edition
MODEL NUMBER
CF LOW LEAKAGE
(Y = YES)
VDC
AMPS
WATTS
Standard Specifications
8
7.6
7.1
6.7
6.3
5.8
5.5
5
5
4.6
4.3
4
3.75
3.3
3
2.7
2.5
2.3
2.15
2
1.85
1.65
1.5
1.35
1.25
40
42
43
44
44
44
44
45
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
• Universal Input Voltage: 90-264Vac 47-63Hz Class I or II
• Output Voltage Tolerance: +/-2.5% Typical, +/-5% Max, from
Full Load to No Load.
• Operating Temperature: 0 - 40°C
• Maximum Output Ripple:
• 5 - 6V: 50mVp-p
• 6.1 - 24V: 100mVp-p
• 24.1 - 36V: 150mVp-p
• 36.1 - 48V 200mVp-p
• Designed for Continuous Duty
• Hold-Up Time : 20mS Minimum @ 120 Vin
• Short Circuit and Over Load Protection
• SELV Output
• MTBF Calculated > 100,000 Hours @ 40°C
• 2 Hour Minimum Loaded Burn-in at 40°C Ambient for
standard output cord configurations
• Leakage current compliant to IEC60601-1 Category B and BF
• 5 Year Warranty
WSL650
WSL655
WSL660
WSL665
WSL670
WSL675
WSL680
WSL690
WSL612
WSL613
WSL614
WSL615
WSL616
WSL618
WSL620
WSL622
WSL624
WSL626
WSL628
WSL630
WSL632
WSL636
WSL640
WSL644
WSL648
Y
Y
Y
Y
Y
Y
Y
5
5.5
6
6.5
7
7.5
8
9
12
13
14
15
16
18
20
22
24
26
28
30
32
36
40
44
48
Available Features
•
•
•
•
•
•
•
•
•
•
•
•
Precision Output Voltage setting
Expanded Operating Temperatures
Power On/Off Switch
400 Hz Input Rating
DC Input Rating
Additional Noise and/or Surge Protection
LED Power On Indicator
Fixed-in-place Input Cord
Wall plug-in configuration
Output Cord Sets and Connector Configurations
Case Colors, Markings & Logos
16 Hour Burn-in
*Add a suffix, “M” for Medical or leave it blank for non-medical.
All specifications are typical at nominal input, full load, and 25°C unless
otherwise noted
© Copyright 2015, Astrodyne, Inc
This document is believed to be correct at time of publication and Astrodyne, Inc
accepts no responsibility for consequences from printing errors or inaccuracies.
Specifications are subject to change without notice
www.AstrodyneTDI.com
PH: 908-353-5700 | FAX: 908-353-1021
WSL 600 SERIES, 60 WATTS
L CASE ENCLOSURE
HIGH EFFICIENCY, COMPACT DESIGN SWITCHMODE TECHNOLOGY
4.75
3.00
1.89
1.89
3.00
ALSO AVAILABLE WITH INTERNATIONAL
PLUG-IN CONFIGURATION
4.75
A. WALL PLUG-IN OPTION
B. INPUT CORD OPTION
3.00
1.89
C. IEC 320 OPTION
VARIOUS INPUT AND OUTPUT CORD
OPTIONS AVAILABLE
4.75
Regulatory Compliance
Designed for use with medical, information technology, and gen-
eral purpose equipment to the following standards: All models are
approved to:
•
•
•
•
•
UL 60601-1 / 60950-1
CSA 22.2 601-1 / 60950-1
TUV EN 60601-1 / 60950-1
CE LVD directive
*cUL Mark
IEC 320 OPTION
USED FOR MOST
INTERNATIONAL APPLICATIONS
4.75
EMC: All models meet European EMC directive and FCC requirements.
Meets all EMC requirements from EN60601-1-2.
Emissions: Level B requirements of FCC CFR 47 part 15 and CISPR11
(EN55011) and CISPR22 (EN55022), EN61000-6-3 (light industrial)
and line harmonic emissions EN61000-3-2.
Immunity: CISPR24 (EN55024), EN61326 and EN61000-3-2.
Certification records are available upon project request.
3.00
TOP SURFACE MARKING
AREA = 4.41 X 2.09
© Copyright 2015, Astrodyne, Inc
This document is believed to be correct at time of publication and Astrodyne, Inc
accepts no responsibility for consequences from printing errors or inaccuracies.
Specifications are subject to change without notice
www.AstrodyneTDI.com
PH: 908-353-5700 | FAX: 908-353-1021