EEWORLDEEWORLDEEWORLD

Part Number

Search

8345-B01A-S3K2-DB1B2B-X8345-S01HW102M-15A

Description
Circuit Breakers
CategoryCircuit protection   
File Size700KB,10 Pages
ManufacturerE-T-A Circuit Breakers
Download Datasheet Parametric View All

8345-B01A-S3K2-DB1B2B-X8345-S01HW102M-15A Overview

Circuit Breakers

8345-B01A-S3K2-DB1B2B-X8345-S01HW102M-15A Parametric

Parameter NameAttribute value
Product AttributeAttribute Value
ManufacturerE-T-A Circuit Breakers
Product CategoryCircuit Breakers
ProductHydraulic Magnetic Circuit Breakers
Current Rating15 A
Number of Poles1 Pole
Actuator TypeLever
Minimum Operating Temperature- 40 C
Maximum Operating Temperature+ 85 C
IlluminatedNot Illuminated
Height19.1 mm
Length63.5 mm
Width48 mm
Mounting StyleFlange
Magnetic and Hydraulic-Magnetic Circuit Breaker 8345-...
Description
Single or multipole hydraulic-magnetic circuit breakers with trip-free-
mechanism and toggle actuation. A choice of switching characteristics
ensures suitability for a wide range of applications. Industry standard
dimensions and panel mounting. Auxiliary contacts optional. Low
temperature sensitivity at rated load.
Approved to CBE standard EN 60934 (IEC 60934) S-type HM CBE.
Typical applications
In the business fields Communication and Transport: power supplies,
switchgear, instrumentation and process control engineering.
1-pole
Standard current ratings and typical internal resistance values
Current
rating (A)
0,05
0,1
1
2
3
5
10
15
20
25
30
40
50
60
80
100
125
Trip curves and internal resistance (Ω) per pole
F1
---
---
0,578
0,144
0,0644
0,0250
0,00901
0,00597
0,00468
0,00410
0,00385
0,00371
0,00358
---
---
---
---
---
---
0,347
0,0959
0,0477
0,0192
0,00714
0,00483
0,00410
0,00385
0,00371
0,00371
0,00358
---
---
---
---
F2
K1, M1, T1
531
129
1,10
0,295
0,121
0,0437
0,0147
0,00794
0,00597
0,00456
0,00458
0,00373
0,00335
0,00333
0,00325
0,00316
0,00314
K2, M2, T2
542
127
1,08
0,291
0,118
0,0449
0,0133
0,00794
0,00597
0,00456
0,00458
0,00373
0,00335
0,00333
0,00325
0,00316
0,00314
8345
1
2-pole
Technical data
Voltage rating
3 AC 415 V; AC 277/480 V;
AC 120/240 V; AC 240 V; DC 80 V
(higher DC voltages to special order)
0.02...125 A single and multipole
higher ratings upon request
AC 240 V 6 A
DC 28 V 3 A
DC 65 V 1 A
DC 80 V 0.5 A
10,000 operations at 1 x I
N
-40...+85 °C (-40...+185 °F)
2.5 kV/2
reinforced insulation in operating area
test
test
test
test
test
voltage
voltage
voltage
voltage
voltage
AC
AC
AC
AC
AC
3,000
1,500
1,500
3,000
1,500
V
V
V
V
V
Current rating range
Auxiliary circuit
Typical life
Ambient temperature
Insulation co-ordination
(IEC 60664)
Dielectric strength
operating area
Line to Load
pole to pole
(2- and 3-pole)
main to auxiliary circuit
switching to trip circuit
(version -X)
Insulation resistance
Degree of protection
(IEC 60529)
Vibration
mounting attitude
toggle down:
other mounting attitudes:
with curves F1, F2:
> 100 MΩ (DC 500 V)
operating area IP40
terminal area IP00
10 g (57-2000 Hz) ± 0,76 mm (10-57 Hz)
at 0.9 x I
N
10 g at 1 x I
N
10 g at 0.8 x I
N
in all mounting attitudes
(57-2000 Hz) ± 0.76 mm (10-57 Hz)
to IEC 60068-2-6, test Fc
10 frequency cycles/axis
100 g (11 ms) at 1 x I
N
,
100 g (11 ms) at 0.8 x I
N
,
100 g (11 ms) at 0.8 x I
N
to IEC 60068-2-27, test Ea
96 hours at 5 % salt mist,
to IEC 60068-2-11, test Ka
240 hours at 95 % RH,
to IEC 60068-2-78, test Cab
approx. 90 - 120 g per pole
depending on version
Interrupting capacity
to EN 60934, CCC, UL 489, UL 1077
IEC 60934 / CCC (3-pole) – test series E:
voltage
DC 80 V
AC 240/415 V
AC 240 V
voltage
DC 80 V
AC 120 V
AC 120/240 V
AC 240 V
voltage
DC 80 V
AC 277/480 V
number of
poles
1+2
1–4
1
number of
poles
1+2
1
1 (2)
1
UL 1077:
number of
poles
1+2
1–4
I
N
max. (A)
0.02...125
0.02...70
I
cn
(A)
10 000
5 000
I
N
max. (A)
0.02...125
0.016...80
0.016...20
I
N
max. (A)
0.5...125
0.5...80
0.5...80
0.5...20
I
cn
(A)
10 000
6 x I
N
5 000
I
cn
(A)
10 000
5 000
5 000
5 000
Shock
directions 1, 2, 3, 4, 5:
direction 6:
with curves F1, F2:
Corrosion
Humidity
Mass
UL 489 – test sequence Z:
1801
www.e-t-a.de
1
Advantages of the STOP function in low-noise data acquisition applications
Electromagnetic noise is any unwanted electromagnetic energy that is strong enough to distort a signal. Therefore, noise must be overcome when designing high-performance data acquisition applications ...
alan000345 Microcontroller MCU
UC3842 power supply problem
(Picture from the Internet, please delete if infringed)Image Description: As shown in the figure, line 1 passing through the rectifier bridge provides a starting voltage to 3842 through the starting r...
普拉卡图 Switching Power Supply Study Group
I would like to ask how to set up Xnet in allegro
I would like to ask how to set up Xnet in allegro...
asionl PCB Design
The problem of STM8L151k4t6 with programmed code being damaged by soldering?
[table=98%] [tr][td] [align=center] [/align] [color=#333333][size=16px][align=center][color=rgb(102, 102, 102)][ size=18px][color=#4183c4][url=][img=16,0]http://bbs.elecfans.com/template/elecfans_2018...
轻轻飘过shn stm32/stm8
DSP28335 external interrupt configuration process
28335 External Interrupt Basic Features 7 maskable interrupt sources and 1 non-maskable external interrupt sourceGPIO0-31 optional interrupt sources are XINT1 (maskable interrupt), XINT2 and XNMI (non...
fish001 DSP and ARM Processors
Circuit PCB Design
The two development boards communicate with each other through a network cable. Now we need to design the two boards into one board, eliminating the crystal head and network cable, connect the network...
dabing88 PCB Design

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号