EEWORLDEEWORLDEEWORLD

Part Number

Search

175D

Description
Autotransformers 500VA 230 TO 115VAC
CategoryPower management    transformer   
File Size339KB,2 Pages
ManufacturerHammond
Websitehttp://www.hammondmfg.com
Download Datasheet Parametric Compare View All

175D Online Shopping

Suppliers Part Number Price MOQ In stock  
175D - - View Buy Now

175D Overview

Autotransformers 500VA 230 TO 115VAC

175D Parametric

Parameter NameAttribute value
MakerHammond
Reach Compliance Codecompliant
ECCN codeEAR99
Transformer typeAUTO TRANSFORMER
~
Single winding for use where equipment is already isolated
and only voltage change is required
~ Does not provide isolation
~
Input is circuit breaker protected
~
Hi-pot tested to 2 KV RMS
~
Standard 3-wire, grounded plug (can also be used with
adaptors for proper grounding)
~
Input connected to a 5 foot cord & grounded North American
230V plug
~
Output connected to a standard N. American 115V - 3 wire
grounded receptacle (NEMA 5-15R)
~
North American Mark of Safety: cUL & UL listed
230VA
115VA
230VAC to 115VAC
Down (North American
Step Down (Nor th Amer ican 230V Plug & 115V Receptacle)
Pa r t No.
175A-NA
175B-NA
175C-NA
175D-NA
175E-NA
175F-NA
175G-NA
Capacity
VA
VA
100
200
300
500
750
1000
1500
Di mensi ons ( I nches)
W
3.16
3.16
3.16
3.80
3.80
3.80
4.40
D
4.25
4.50
5.00
6.00
7.06
7.06
6.63
H
3.81
3.81
3.81
4.68
4.68
4.68
5.39
Mount i ng Hol e
Centers (Inches)
W
D
2.50
2.94
2.50
3.19
2.50
3.69
3.00
4.38
3.00
5.38
3.00
538
3.50
6.09
Shipping
We i g h t
3.5
4.5
6.0
10.0
14.0
14.5
22.0
~
Single winding for use where equipment is already isolated
and only voltage change is required
~ Does not provide isolation
~
Input is circuit breaker protected
~
Hi-pot tested to 2 KV RMS
~
Standard 3-wire, grounded plug (can also be used with
adaptors for proper grounding)
~
Input connected to a 5 foot cord & standard grounded
European (Schuko) plug
~
Output connected to a standard N. American 115V - 3 wire
grounded receptacle (NEMA 5-15R)
~
North American Mark of Safety: cUL & UL listed
230VA
115VA
230VAC to 115VAC
Down
North American
Step Down (European Plug & Nor th Amer ican Receptacle)
Pa r t No.
175A-EU
175B-EU
175C-EU
175D-EU
175E-EU
175F-EU
175G-EU
Capacity
VA
VA
100
200
300
500
750
1000
1500
Di mensi ons ( I nches)
W
3.16
3.16
3.16
3.80
3.80
3.80
4.40
D
4.25
4.50
5.00
6.00
7.06
7.06
6.63
H
3.81
3.81
3.81
4.68
4.68
4.68
5.39
Mount i ng Hol e
Centers (Inches)
W
D
2.50
2.94
2.50
3.19
2.50
3.69
3.00
4.38
3.00
5.38
3.00
538
3.50
6.09
Shipping
We i g h t
3.5
4.5
6.0
10.0
14.0
14.5
22.0
28
©
Hammond Manufacturing Co. Ltd.
394 Edinburgh Rd. North
Guelph, Ontario N1H 1E5 CANADA
Phone: 519-822-2960 Fax: 519-822-0715
ww
w.h
am m
ond
mfg
.co
m
Hammond Manufacturing Co. Inc.
256 Sonwil Dr.
Cheektowaga, NY 14225
USA
Phone: 716-651-0086 Fax: 716-651-0726

175D Related Products

175D 175G-EU 175E-EU
Description Autotransformers 500VA 230 TO 115VAC Autotransformers 1500VA STEPDOWN EURO Autotransformers 750VA STEPDOWN EURO
Reach Compliance Code compliant compliant compliant
Transformer type AUTO TRANSFORMER AUTO TRANSFORMER AUTO TRANSFORMER
Is it Rohs certified? - conform to conform to
Is Samacsys - N N
Base Number Matches - 1 1
Design and implementation of temperature control system based on MSP430
Temperature control devices such as refrigerators, freezers, and air conditioners have been widely used in the general public. These devices have brought more comfort to people, and people are becomin...
fish001 Microcontroller MCU
[Erha Image Recognition Artificial Intelligence Vision Sensor] Evaluation 2: Built-in 7 functions, face recognition and other tests
[i=s]This post was last edited by mameng on 2021-12-13 16:03[/i]Built-in 7 functions: face recognition, object tracking, object recognition, line tracking, color recognition, label recognition, object...
mameng Domestic Chip Exchange
【TouchGFX Design】Decomposition of the generated project directory structure and recommendation of two C++ introductory books
[i=s] This post was last edited by boming on 2019-4-22 21:44 [/i] The generated project directory structure is decomposed and two C++ introductory books are recommended. In the previous section, in or...
boming stm32/stm8
consult
How to change the name of cellview in cadence617?...
nbh1234 Analogue and Mixed Signal
Nuvoton's new development board Chili allows you to complete Linux application development in 40 minutes
Currently, Ethernet and Wi-Fi are widely used in the IoT world. The demand for related network applications is increasing year by year. In addition to Ethernet and Wi-Fi, wireless transmission interfa...
火辣西米秀 Domestic Chip Exchange
Common basic knowledge of 4G DTU
1. What is DTU? Answer: DTU is the abbreviation of Data Terminal Unit. In a broad sense, during communication, the module units responsible for sending data information at both ends of the data transm...
baimatech77 Industrial Control Electronics

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号