Max.
1000
m /h
3
AC axial fans
225 x 80 mm
– Material:
Housing: Die-cast-aluminum
Impeller: Sheet steel, painted black
Rotor: Painted black
Number of blades:
7
Direction of air flow:
"V"
Direction of rotation:
Counterclockwise, looking towards rotor
Degree of protection:
IP 44, depending on installation and position
Insulation class:
"B"
Installation position:
Any
Condensation drainage holes:
None
Mode of operation:
Continuous operation (S1)
Bearings:
Maintenance-free ball bearings
–
–
–
–
–
–
–
–
–
Admissible amb. temp.
Max. back-pressure
Power consumption
Capacitor
Sound power level
Nominal voltage
Nominal speed
Input current
Frequency
Air flow
Nominal data
Type
W2E 200-HK86-01
W2E 200-HK38-01
Subject to change
Motor
M2E 068-BF
M2E 068-BF
A
B
VAC
1~115
1~115
1~230
1~230
Hz
50
60
50
60
m
3
/h
880
1000
880
1000
rpm
-1
2550
2800
2550
2800
W
64
80
64
80
A
0.58
0.70
0.29
0.35
F/VDB
5.0/220
5.0/220
1.5/450
1.5/450
dB(A)
—-
—-
—-
—-
Pa
°C
80 -25...+60
95 -25...+65
80
95
-25...+60
-25...+65
Weight
Curve
kg
2.0
2.0
2.1
2.1
P. 263 / A1)
P. 263 / A1)
C
D
Curves:
n
rpm
-1
B D
A
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
P
ed
W
56
58
61
64
67
71
75
80
60
64
66
69
70
73
77
83
I
A
0.56
0.57
0.58
0.60
0.58
0.62
0.65
0.69
0.30
0.31
0.31
0.32
0.31
0.32
0.34
0.36
L
W
A
dB(A)
—-
—-
—-
—-
—-
—-
—-
—-
—-
—-
—-
—-
—-
—-
—-
—-
in wg
Pa
0.4
100
2640
2595
2550
2480
2980
2880
2790
2660
2630
2585
2530
2480
3000
2935
2850
2705
A
A
A
80
A C
B
B
B
60
0.2
B
C
C
40
C
C
D
20
D
D
D
P
fs
0
100
200
300
400
500
cfm
q
v
200
400
600
800
m³/h
Air performance measured according to: ISO 5801, Installation category A. For detailed information on the measurement setup, contact ebm-
papst. Suction-side noise levels: L
W
A according to ISO 13347, L
p
A measured at 1 m distance from fan axis. The values given are applicable only
under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard
configuration, the parameters must be checked after installation! For detailed information see http://www.ebmpapst.com/general conditions
2016-01
220
Connection diagram
–
–
–
–
–
–
–
Motor protection:
Touch current:
Cable exit:
Electrical hookup:
Protection class:
Conformity with standard(s):
Approvals:
Thermal overload protector (TOP) connected internally
< 0.75 mA acc. to IEC 60990 (test circuit, illustration 4)
Variable
Via terminal strips, capacitor connected
I (with customer connection to grounding conductor)
EN 60335-1, CE
A B
EAC, UL 507, VDE, CSA C22.2 no. 113, CCC
C D
EAC, UL 2111, VDE, CSA C22.2 no. 113, CCC
"V"
›
N
L
PE
N L
221
2016-01
Finger guards
from p. 245
Connection diagrams
P. 263
Representatives
Ø240
Ø260
7
80
±0.3
7
Accessories
Ø4.5
+0.2
(8x)
AC centrifugal fans
AC axial fans
22
5
ACmaxx /
EC fans
fans
ACmaxx
DC fans
- specials
DC centrifugal fans
DC axial fans
Information