5600/5700 Series Delay On Release Timers
Fixed/Adjustable Timing, Relay Output
Product Facts
■
■
■
■
■
■
DC input delay on release
timer offered in fixed (5600)
and adjustable (5700) types
Up to 10A loads
Reverse polarity protection
CMOS digital design
Built to MIL-R-83726
environmentals
Many customizing options
■
Extended timing ranges
■
Tighter timing tolerances
■
Header and mounting
■
Different Aux. voltages
■
Different control line
voltages
■
Input either 115Vac, 60 Hz.
or 400 Hz.
CII 5600/6700 series delay on
release timers combine solid
state timing circuits with
electromechanical output
relays in robust hermetically
sealed enclosures. The 5600
types are fixed timers, while the
5700 models are adjustable via
an external resistor. Numerous
output options include 2A, 5A
and 10A rated contacts in 1,
and 2 form C (SPDT and DPDT)
arrangements.
Electrical Specifications
Timing Range:
5600 series (fixed):
50 ms to 600 s.
5700 series (adjustable):
50 ms to
240 s.
Tolerance:
±10% or ±15ms, whichever
is less
Recycle Time:
10 ms .
Reset Time:
20 ms .
Operate Time (Max.) :
10 ms (2A
and 5A models), 20ms (10A models).
Input Voltage:
18 to 31Vdc.
Control Voltage:
10 to 31Vdc. Ground
common to aux. power line. 10Vdc
minimum must be applied for a
minimum duration of 20ms to energize
output and initiate the timing circuit.
Current Drain (at 25°C, 28Vdc):
Control Line:
15mA typ., 25mA max.
Input Line De-energized (after
completion of delay period):
125
mA.
Input Line Energized:
1-pole, 2 & 5A models:
100mA.
1-pole, 10A models:
150mA.
2-pole, 2 & 5A models:
150mA.
2-pole,10A models:
240mA.
Contact Ratings:
10A contacts:
10A resistive @ 30Vdc.
5A inductive @ 30Vdc.
5A resistive @ 115 Vrms, 400 Hz
3A inductive @ 115 Vrms, 400 Hz
5A contacts:
5A resistive @ 30Vdc.
1.5A inductive @ 30Vdc.
3A resistive @ 115 Vrms, 400 Hz
1A inductive @ 115 Vrms, 400 Hz
2A contacts:
2A resistive @ 30Vdc.
1A inductive @ 30Vdc.
1A resistive @ 115 Vrms, 400 Hz
0.3A inductive @ 115 Vrms, 400 Hz
Specifications by Model Number
Fixed Timer
Model Number
5601
5602
5605
5606
5610
5611
Adjustable Timer Input
Model Number Voltage
5701
DC
5702
DC
5705
5706
5710
5711
DC
DC
DC
DC
Temperature
Range
-55°C to +85°C
-55°C to +85°C
-55°C to +85°C
-55°C to +85°C
-55°C to +85°C
-55°C to +85°C
Contact
Rating
2 Amp
2 Amp
5 Amp
5 Amp
10 Amp
10 Amp
Contact
Arrangement
1 Form C (SPDT)
2 Form C (DPDT)
1 Form C (SPDT)
2 Form C (DPDT)
1 Form C (SPDT)
2 Form C (DPDT)
Available
Enclosures
A-C-D-E
A-C-D-E
D-E
D-E
D-E
D-E
A-C-D-E
A-C-D-E
D-E
D-E
5621
5721
DC
-55°C to +125°C
2 Amp
1 Form C (SPDT)
5622
5722
DC
-55°C to +125°C
2 Amp
2 Form C (DPDT)
5625
5725
DC
-55°C to +125°C
5 Amp
1 Form C (SPDT)
5626
5726
DC
-55°C to +125°C
5 Amp
2 Form C (DPDT)
See next page for complete ordering information and outline dimensions for the available enclosures.
Environmental Specifications
Temperature Range:
-55°C to +85°C or -55°C to +125°C.
Vibration:
20 G’s, 10 - 2,000 Hz.
Shock:
50 G’s, 11 ± 1ms duration.
Insulation Resistance:
1,000
megohms, min., at 500Vdc.
Dielectric Strength:
1,000Vrms, 60
Hz., at sea level, all terminals to case.
Sealing:
Hermetic, 1.3 in. (33.0mm) of
mercury.
Life:
100,000 operations, min. (2A and
5A models); 50,000 operations, min.
(10A models);
Weight:
8.5 oz (240g) max.
Adjustable Timing Formula
(4700 types)
The resistance required to obtain timing
within this range is determined by using
the formula:
Rx = 400K (T/Tmax.) – 40K, where
Rx = External Resistance in Ohms,
T - Desired Time in Seconds, and
Tmax. = Maximum Time (Code).
A high quality deposited carbon ±1%,
0.1W (min.) resistor is recommended for
external resistance.
Timing Diagram
INPUT
CONTROL
OUTPUT
ON
OFF
ON
OFF
ON
OFF
<--- DELAY --- >
Apply input power. Upon application of
control power, the output will energize.
Remove control power and initiate delay
period.
Special Notes
10Vdc mimimum must be applied for a
minimum duration of 20ms to energize
output and initiate timing.
Units rated 10A have a minimum time
delay of 100ms.
© 2005 by Tyco Electronics Corporation. All Rights Reserved.
CII and TYCO are trademarks.
Other products and company names mentioned herein may be trademarks of their respective owners.
1
Catalog 8-1773439-1
Revised 4-05
www.tycoelectronics.com
Dimensions are in inches and
millimeters unless otherwise
specified. Values in brackets
are metric equivalents.
Dimensions are shown for
reference purposes only.
Specifications subject
to change.
USA: 1-800-522-6752
Canada: 1-905-470-4425
Mexico: 01-800-733-8926
C. America: 52-55-5-729-0425
South America: 55-11-3611-1514
Hong Kong: 852-2735-1628
Japan: 81-44-844-8013
UK: 44-141-810-8967
High Performance Electronic Products
5600/5700 Series Delay On Release Timers
(Continued)
Part Numbering System
Typical Part Number
5722
–C
– 1102
Model Number:
Four digit code from table on the previous page.
Mounting (see outline dimension drawings):
A = Studs on bottom of 2.5 in tall case
C = Studs on side of 2.5 in. tall case
D = Studs on bottom of 1.812 in. tall case
E = Bracket on side of 1.812 in. tall case
Timing Code:
Four-digit code for any value between 50ms and 600s for fixed (5600) timers and between 50ms and 240s for adjustable (5700) timers.
The timing code consists of four digits and gives the time in ms. The first three digits are the significant figures and the last digit is the number of zeros following the significant
figures; thus 50 ms would be coded 0500, 1.1 s would read 1101, and 1 m (60 s) would be 6002.
Adjustable timers cover one decade, e.g., 62 ms to 620 ms. The upper decade limit is Tmax. in the timing formula and is the the value defined by the timing code in the part
number.
Note: Units with 10A contacts have a minimum time delay of 100ms.
A typical part number for an adjustable timer would be 5722–C–1102. This DC unit is in the -55°C to +125°C temperature range with a 2 amp contacts in a 2 form C (DPDT)
arrangement, enclosed in case with a style “C” mounting, with a maximum time delay of 11s.
Outline Dimensions
.625
[15.875]
.305
[7.747]
2.491 MAX.
2.09 [63.27]
[53.09]
.875
[22.22]
1.812 MAX.
[46.02]
2.50 MAX.
[63.5]
2.50 MAX.
[63.5]
.625
[15.875]
.281 MAX.
[7.14]
.375
[9.53]
#4-40 UNC-2A
INDEX DOT
4 PLACES
1.0 MAX.
[25.4]
.625
[15.875]
.875
1.25 MAX. [22.22]
[31.75]
.81 DIA.
[20.57]
MAX.
.469 MAX.
[11.91]
.380 TYP.
[9.53]
.063 MAX.
[1.60]
1.0 MAX.
[25.4]
1.25 MAX.
[31.75]
.810 DIA.
[20.57]
MAX.
.547
[13.89]
1.25
[31.75]
1.812
[46.02]
.063 MAX.
[1.60]
.375
[9.53]
.281 MAX.
[9.53]
INDEX DOT
#6-32 UNC-2A
4 PLACES
.531
[13.49]
1.542
[39.17]
INDEX DOT
#4-40 UNC-2A
4 PLACES
1.542
[39.17]
1.187
[30.15]
1.542
[39.17]
.063 MAX.
[1.60]
INDEX
DOT
1.187
1.542 [30.15]
[39.17]
Mounting Option A
Mounting Option C
Mounting Option D
Mounting Option E
Wiring Diagrams
–
–
AUX.
INPUT
+
CONTROL +
CONTROL +
–
–
AUX.
INPUT
TIMING
RESISTOR
CONTROL +
+
5600 Series
(Fixed)
AUX.
INPUT
+
5700 Series
(Adjustable)
AUX.
INPUT
+
+
CONTROL
TIMING
RESISTOR
1 Form C
2 Form C
1 Form C
2 Form C
2
Catalog 8-1773439-1
Revised 4-05
www.tycoelectronics.com
Dimensions are in inches and
millimeters unless otherwise
specified. Values in brackets
are metric equivalents.
Dimensions are shown for
reference purposes only.
Specifications subject
to change.
USA: 1-800-522-6752
Canada: 1-905-470-4425
Mexico: 01-800-733-8926
C. America: 52-55-5-729-0425
South America: 55-11-3611-1514
Hong Kong: 852-2735-1628
Japan: 81-44-844-8013
UK: 44-141-810-8967