Note: In case of 5 V drive circuit, it is recommended to use 4.5 V type relay.
ASCTB76E 201201-T
Panasonic Corporation
Automation Controls Business Unit
industrial.panasonic.com/ac/e
TK
TYPES
1) Standard PC board terminal
Contact
arrangement
Nominal coil
voltage
1.5V DC
3V DC
4.5V DC
1 Form C
5V DC
6V DC
9V DC
12V DC
24V DC
Standard packing: Tube: 50 pcs.; Case: 1,000 pcs.
Single side stable
Part No.
TK1-1.5V
TK1-3V
TK1-4.5V
TK1-5V
TK1-6V
TK1-9V
TK1-12V
TK1-24V
1 coil latching
Part No.
TK1-L-1.5V
TK1-L-3V
TK1-L-4.5V
TK1-L-5V
TK1-L-6V
TK1-L-9V
TK1-L-12V
TK1-L-24V
2 coil latching
Part No.
TK1-L2-1.5V
TK1-L2-3V
TK1-L2-4.5V
TK1-L2-5V
TK1-L2-6V
TK1-L2-9V
TK1-L2-12V
TK1-L2-24V
2) Self-clinching terminal
Contact
arrangement
Nominal coil
voltage
1.5V DC
3V DC
4.5V DC
5V DC
6V DC
9V DC
12V DC
24V DC
Single side stable
Part No.
TK1-H-1.5V
TK1-H-3V
TK1-H-4.5V
TK1-H-5V
TK1-H-6V
TK1-H-9V
TK1-H-12V
TK1-H-24V
1 coil latching
Part No.
TK1-L-H-1.5V
TK1-L-H-3V
TK1-L-H-4.5V
TK1-L-H-5V
TK1-L-H-6V
TK1-L-H-9V
TK1-L-H-12V
TK1-L-H-24V
2 coil latching
Part No.
TK1-L2-H-1.5V
TK1-L2-H-3V
TK1-L2-H-4.5V
TK1-L2-H-5V
TK1-L2-H-6V
TK1-L2-H-9V
TK1-L2-H-12V
TK1-L2-H-24V
1 Form C
Standard packing: Tube: 50 pcs.; Case: 1,000 pcs.
RATING
1. Coil data
1) Single side stable
Nominal coil
voltage
1.5V DC
3V DC
4.5V DC
5V DC
6V DC
9V DC
12V DC
24V DC
Pick-up voltage
(at 20°C
68°F)
Drop-out voltage
(at 20°C
68°F)
Nominal operating
current
[±10%] (at 20°C
68°F)
93.8mA
46.7mA
31mA
28.1mA
23.3mA
15.5mA
11.7mA
11.3mA
Coil resistance
[±10%] (at 20°C
68°F)
16Ω
64.3Ω
145Ω
178Ω
257Ω
579Ω
1,028Ω
2,133Ω
Nominal operating
power
Max. applied voltage
(at 20°C
68°F)
75%V or less of
nominal voltage*
(Initial)
10%V or more of
nominal voltage*
(Initial)
140mW
150%V of
nominal voltage
270mW
120%V of
nominal voltage
2) 1 coil latching
Nominal coil
voltage
1.5V DC
3V DC
4.5V DC
5V DC
6V DC
9V DC
12V DC
24V DC
*Pulse drive (JIS C 5442-1986)
Set voltage
(at 20°C
68°F)
Reset voltage
(at 20°C
68°F)
Nominal operating
current
[±10%] (at 20°C
68°F)
66.7mA
33.3mA
22.2mA
20mA
16.7mA
11.1mA
8.3mA
6.3mA
Coil resistance
[±10%] (at 20°C
68°F)
22.5Ω
90Ω
202.5Ω
250Ω
360Ω
810Ω
1,440Ω
3,840Ω
150mW
120%V of
nominal voltage
Nominal operating
power
Max. applied voltage
(at 20°C
68°F)
75%V or less of
nominal voltage*
(Initial)
75%V or less of
nominal voltage*
(Initial)
100mW
150%V of
nominal voltage
Panasonic Corporation
Automation Controls Business Unit
industrial.panasonic.com/ac/e
ASCTB76E 201201-T
TK
3) 2 coil latching
Nominal coil
voltage
1.5V DC
3V DC
4.5V DC
5V DC
6V DC
9V DC
12V DC
24V DC
*Pulse drive (JIS C 5442-1986)
Set voltage
(at 20°C
68°F)
Reset voltage
(at 20°C
68°F)
Nominal operating
current
[±10%] (at 20°C
68°F)
Set coil
133.9mA
66.7mA
44.5mA
40mA
33.3mA
22.2mA
20.8mA
16.7mA
Reset coil
133.9mA
66.7mA
44.5mA
40mA
33.3mA
22.2mA
20.8mA
16.7mA
Coil resistance
[±10%] (at 20°C
68°F)
Set coil
11.2Ω
45Ω
101.2Ω
125Ω
180Ω
405Ω
576Ω
1,440Ω
Reset coil
11.2Ω
45Ω
101.2Ω
125Ω
180Ω
405Ω
576Ω
1,440Ω
250mW
400mW
250mW
400mW
120%V of
nominal voltage
110%V of
nominal voltage
200mW
200mW
150%V of
nominal voltage
Nominal operating
power
Set coil
Reset coil
Max. applied voltage
(at 20°C
68°F)
75%V or less of
nominal voltage*
(Initial)
75%V or less of
nominal voltage*
(Initial)
2. Specifications
Characteristics
Arrangement
Contact
Initial contact resistance, max.
Contact material
Nominal switching capacity
Max. switching power
Max. switching voltage
Max. switching current
Min. switching capacity (Reference value)*
1
Single side stable
Nominal operating
1 coil latching
power
2 coil latching
Insulation resistance (Initial)
Breakdown voltage
(Initial)
Electrical
characteristics
Surge breakdown
voltage (Initial)
Between open contacts
Between contact and coil
Between open contacts
Between contacts and coil
Item
1 Form C
Max. 50 mΩ (By voltage drop 6 V DC 1A)
Ag+Au clad
2 A 30 V DC (resistive load)
60 W (DC) (resistive load)
220 V DC
2A
10µA 10mV DC
140 mW (1.5 to 12 V DC), 270 mW (24 V DC)
100 mW (1.5 to 12 V DC), 150 mW (24 V DC)
200 mW (1.5 to 9 V DC), 250 mW (12 V DC), 400 mW (24 V DC)
Min. 1,000MΩ (at 500V DC)
Measurement at same location as “Initial breakdown voltage” section.
750 Vrms for 1 min. (Detection current: 10 mA)
1,500 Vrms for 1 min. (Detection current: 10 mA)
1,500 V (10×160µs) (FCC Part 68)
2,500 V (2×10µs) (Telcordia)
Max. 50°C
(By resistive method, nominal coil voltage applied to the coil; contact carrying current: 2A.)
Max. 3 ms [Max. 3 ms] (Nominal coil voltage applied to the coil, excluding contact bounce
time.)
Max. 2 ms [Max. 3 ms] (Nominal coil voltage applied to the coil, excluding contact bounce
time.) (without diode)
Min. 750 m/s
2
(Half-wave pulse of sine wave: 6 ms; detection time: 10µs.)
Min. 1,000 m/s
2
(Half-wave pulse of sine wave: 6 ms.)
10 to 55 Hz at double amplitude of 3.3 mm (Detection time: 10µs.)
10 to 55 Hz at double amplitude of 5 mm
Min. 10
8
(Single side stable), Min. 5×10
7
(1 or 2 coil latching) (at 180 cpm)
Min. 10
5
(2 A 30 V DC resistive) (at 20 cpm)
Ambient temperature: –40°C to 85°C
–40°F to 185°F*
3
;
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
20 cpm
Approx. 1 g
.035 oz.
Specifications
Rating
Temperature rise (at 20°C
68°F)
Operate time [Set time] (at 20°C
68°F)
Release time [Reset time] (at 20°C
68°F)
Functional
Destructive
Functional
Vibration resistance
Destructive
Mechanical
Electrical
Shock resistance
Conditions for operation, transport and storage*
2
Max. operating speed (at rated load)
Unit weight
Mechanical
characteristics
Expected life
Conditions
Notes: *1 This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the
actual load. (TX/TX-S/TX-D relay AgPd contact type are available for low level load switching [10V DC, 10mA max. level])
*2 Refer to 6. Conditions for operation, transport and storage mentioned in AMBIENT ENVIRONMENT .
*3 The maximum ambient temperature allows for coil temperature rise at maximum allowable coil voltage.
As for the applicable range of continuous carrying current against temperature, please refer to “Maximum value of continuous carrying current” chart.
ASCTB76E 201201-T
Panasonic Corporation
Automation Controls Business Unit
industrial.panasonic.com/ac/e
TK
REFERENCE DATA
1. Maximum value of continuous carrying current
Test conditions:
Coil applied voltage: 110% of rated voltage
Continuous carrying current: 1,000 hours
Continuous carrying current, A
3.0
Switching current, A
2
2.0
DC load
100
No. of operations,
×10
4
2. Maximum switching capacity
3. Life curve
1.0
30 V DC resistive
10
1
0.5
0.4
0.3
0.2
0
40
50
60
70
80 85 90
Ambient temperature,
°
C
20 30
50
100
200 300
Switching voltage, V
0
1
2
Switching current, A
4. Mechanical life
Tested sample: TK1-12V, 8 pcs.
Switching frequency: 30 Hz
100
Ratio against the rated voltage, %V
90
80
70
60
50
40
30
20
10
0
10
Drop-out voltage
Max.
Min.
100
1,000
10,000
No. of operations,
×10
4
Min.
Pick-up voltage
Max.
5. Electrical life (DC load)
Tested sample: TK1-12V, 10 pcs.
Condition: 2 A 30 V DC resistive load, 20 cpm
Change of pick-up and drop-out voltage
Ratio against the rated voltage, %V
100
90
80
70
60
50
40
30
20
10
0
No. of operations,
×10
4
Min.
10
Drop-out voltage
Max.
Pick-up voltage
Max.
Min.
Change of contact resistance
100
Contact resistance, mΩ
90
80
70
60
50
40
30
20
10
0
No . of operations,
×10
4
10
Max.
Min.
6.-(1) Coil temperature rise
Tested sample: TK1-12V, 6 pcs.
Measured portion: Inside the coil
Ambient temperature: 25°C
77°F
Room temperature
0A
60
1A
2A
50
40
30
20
10
0
6.-(2) Coil temperature rise
Tested sample: TK1-12V, 6 pcs.
Measured portion: Inside the coil
Ambient temperature: 70°C
158°F
70°C
Temperature rise,
°C
60
50
40
30
20
10
0
0A
1A
2A
Temperature rise,
°C
80 90 100 110 120 130 140 150
Coil applied voltage, %V
80 90 100 110 120 130 140 150
Coil applied voltage, %V
7.-(1) Operate/release time characteristics
Tested sample: TK1-5 V, 50 pcs.
7.-(2) Operate/release time characteristics
Tested sample: TK1-5 V, 50 pcs.
8. Ambient temperature characteristics
Tested sample: TK1-12V, 5 pcs.
Variation ratio, %
40
30
20
10
20 40
60
Drop-out
voltage
−
x
−
x
Pick-up
voltage
<Without diode>
<With diode>
Operate/release time, ms
4
Operate/release time, ms
4
3
3
–40 –20
2
Release time
Max.
Max.
Min.
Min.
Operate time
80
90
100 110 120
Coil applied voltage, %V
0
0
80
Ambient
–10 temperature,
°C
–20
–30
–40
2
Operate time
Max.
Max.
Min.
Min.
1
Release time
0
80
1
90
100 110 120
Coil applied voltage, %V
0
Panasonic Corporation
Automation Controls Business Unit
industrial.panasonic.com/ac/e
ASCTB76E 201201-T
TK
9.-(1) High-frequency characteristics
(Isolation)
9.-(2) High-frequency characteristics (Insertion
loss)
1.8
1.6
1.4
Insertion loss, dB
Isolation, dB
100
1.2
1.0
0.8
0.6
0.4
N.O.
N.C.
0
10
100
Frequency, MHz
1,000
0.2
0
Y
10
100
Frequency, MHz
1,000
N.C.
,
Z
980m/s
2
980m/s
2
,
980m/s
2
X
,
N.O.
Z
Y
,
Y
,Z XX
10. Malfunctional shock
Tested sample: TK1-12V, 6 pcs. (single side stable);
1. Circuit composition of switching power supplyThe main circuit of the switching power supply is composed of input electromagnetic interference filter (EMI), rectifier filter circuit, power conversio...
[size=4][color=#000000][backcolor=white][font=宋体] The SCI module supports communication between the CPU and other asynchronous devices using standard formats. It has two I/O pins, SCIRXD (serial data ...
One of the most common challenges when creating industrial power supplies is converting AC voltage power to DC voltage power. Almost all applications require changing AC voltage to DC voltage, from ch...
There are 4 types of timing devices in S5PV210, with different functions and features.
1. PWM timer(1) This is the most commonly used timer. The timer we usually refer to is this one. The timer in a s...