Product data sheet
Characteristics
XCSPL583
safety switch XCSPL - elbowed flush lever -
centred - 1NC+1NO -1/2"NPT
Product availability: Non-Stock - Not normally stocked in distribution facility
Main
Commercial Status
Range of product
Product or component
type
Component name
Material
Head type
Insulation
Type of operator
Operator direction
information
Electrical connection
Contacts type and
composition
Contacts operation
Clamping connection
capacity
Cable entry
Number of poles
Commercialised
Preventa Safety detection
Guard switch
XCSPL
Plastic
Turret head rotary lever
Double insulated
Elbowed flush lever
Centred
The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein.
This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications.
It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof.
Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein.
Terminal
1 NC + 1 NO
Slow-break, break before make
1 x 0.5...2 x 1.5 mm² with or without cable end
1 entry tapped 1/2" NPT
2
Complementary
Cable outer diameter
Positive opening
Tripping angle
Mechanical durability
Minimum torque for tripping
Positive opening minimum torque
Contact code designation
0.28...0.39 in (7...10 mm)
With NC contact
5°
1000000 cycles
0.88 lbf.in (0.1 N.m)
2.21 lbf.in (0.25 N.m)
Q300, DC-13 (Ue = 250 V, Ie = 0.27 A) conforming to EN/IEC 60947-5-1
Q300, DC-13 (Ue = 125 V, Ie = 0.55 A) conforming to EN/IEC 60947-5-1
A300, AC-15 (Ue = 240 V, Ie = 3 A) conforming to EN/IEC 60947-5-1
A300, AC-15 (Ue = 120 V, Ie = 6 A) conforming to EN/IEC 60947-5-1
10 A
500 V (degree of pollution: 3) conforming to EN/IEC 60947-1
300 V conforming to CSA C22.2 No 14
300 V conforming to UL 508
6 kV conforming to EN/IEC 60947-5-1
<= 30 mOhm conforming to EN/IEC 60947-5-4
10 A cartridge fuse type gG (gl)
Can reach SIL 3 with the appropriate monitoring system and correctly wired
conforming to IEC 61508
Can reach PL = e with the appropriate monitoring system and correctly wired
conforming to EN/ISO 13849-1
Can reach category 4 with the appropriate monitoring system and correctly wired
conforming to EN/ISO 13849-1
B10d = 5000000 (value given for a life time of 20 years limited by mechanical or
contact wear)
Polyamide PA66 fibre glass impregnated
Stainless steel
1.18 in (30 mm)
6.34 in (161 mm)
1.18 in (30 mm)
0.21 lb(US) (0.095 kg)
1
[Ithe] conventional enclosed thermal current
[Ui] rated insulation voltage
[Uimp] rated impulse withstand voltage
Resistance across terminals
Short circuit protection
Safety level
Safety reliability data
Enclosure material
Lever material
Width
Height
Depth
Product weight
Feb 29, 2016
Environment
Standards
EN 1088/ISO 14119
EN/IEC 60204-1
EN/IEC 60947-5-1
EN/IEC 60947-5-4
EN/ISO 12100
UL 508
CSA C22.2 No 14
BG
CSA
UL
TC
TH
-13...158 °F (-25...70 °C)
-40...158 °F (-40...70 °C)
50 gn (f = 10...500 Hz) conforming to IEC 60068-2-6
50 gn for 11 ms conforming to IEC 60068-2-27
Class II conforming to IEC 60536
IP67 conforming to IEC 60529
Product certifications
Protective treatment
Ambient air temperature for operation
Ambient air temperature for storage
Vibration resistance
Shock resistance
Class of protection against electric shock
IP degree of protection
Ordering and shipping details
Category
Discount Schedule
GTIN
Nbr. of units in pkg.
Package weight(Lbs)
Product availability
Returnability
Country of origin
22411 - LIMIT SWITCHES,IEC,XCKJ
T
00785901326717
1
0.70
Non-Stock - Not normally stocked in distribution facility
N
FR
Offer Sustainability
Sustainable offer status
RoHS
REACh
Product environmental profile
Not Green Premium product
Compliant - since 1136 -
Available
Schneider Electric declaration of conformity
Reference not containing SVHC above the threshold
Download Product Environmental
Contractual warranty
Period
18 months