Parameter NameAttribute value
MakerFuji Electric Co., Ltd.
Reach Compliance Codeunknown
ECCN codeEAR99
body width43 mm
body height80 mm
Body length or diameter108 mm
Maximum coil voltage (AC)48 V
Contact (AC) maximum rated R load10A@600VAC
Maximum contact current (AC)10 A
Maximum contact current (DC)10 A
Contact (DC) maximum rated R load10A@300VDC
Maximum contact voltage (AC)600 V
Maximum contact voltage (DC)300 V
Contact/Output Power TypeAC/DC
Electrical life250000 Cycle(s)
Manufacturer's serial number4SH
Installation featuresDIN-RAIL MOUNT
physical size108mm X 43mm X 80mm
GuidelineBS; CSA; IEC, NEMA; UL; VDE
Relay actionMOMENTARY
Relay function8PST
Relay typePOWER/SIGNAL RELAY
surface mountNO
Termination typeSCREW
Base Number Matches1
"ORANGE LINE" INDUSTRIAL RELAY
Features and Ratings
FEATURES
NEW SH SERIES EXPANDABLE INDUSTRIAL RELAY
APPLICATIONS (U.S. Catalog No.4SH and 4GH Series)
High contact reliability that accommodates electronic devices.
All contacts are bifurcated, providing high contact reliability
(minimum operational voltage and current: 5V and 3mA DC)
and enabling direct input to an electronic control circuit.
A wide variety of optional units.
In addition to an auxiliary contact block (two or four poles),
many function units such as a coil surge suppression unit and
terminal covers can be installed on standard industrial relays.
This allows for flexibility and easy modification in the field.
Snap-on mounting on an IEC or DIN rail.
All models can be mounted on an IEC or DIN Standard
35mm rail.
Meets International Standards.
The SH Series industrial relays conform to the following
International Standards: IEC, NEMA, BS and VDE. They are
also UL, CSA, BV and Lloyd approved.
Compatible with conventional models.
SH Series industrial relays are compatible with the
discontinued Fuji SRCa50-3/X, SRCa50-3F/X, and SRC50-05/X
industrial relays. In addition to the mounting holes needed for
the compatibility, mounting holes based on the IEC Standard
are also provided.
Terminal numbers conforming to IEC Standards.
Terminal numbers are based on IEC Standards.
New design.
The arc extinguishing cover is ivory colored with orange
accents, providing a new look to the conventional industrial
relay.
AC OPERATED INDUSTRIAL RELAYS
U.S. Catalog No.
4SH440#
4SH431#
4SH422#
4SH880#
4SH871#
4SH862#
4SH853#
4SH844#
4SH550#
4SH541#
4SH532#
4SH523#
4SH514#
4SH505#
Aux. Contact
4NO
3NO+1NC
2NO+2NC
8NO
7NO+1NC
6NO+2NC
5NO+3NC
4NO+4NC
5NO
4NO+1NC
3NO+2NC
2NO+3NC
1NO+4NC
5NC
Fuji Type
SH-4
4 POLE
DC OPERATED INDUSTRIAL RELAYS
U.S. Catalog No.
4GH440#
4GH431#
4GH422#
4GH880#
4GH871#
4GH862#
4GH853#
4GH844#
4GH550#
4GH541#
4GH532#
4GH523#
4GH514#
4GH505#
Aux. Contact
4NO
3NO+1NC
2NO+2NC
8NO
7NO+1NC
6NO+2NC
5NO+3NC
4NO+4NC
5NO
4NO+1NC
3NO+2NC
2NO+3NC
1NO+4NC
5NC
Fuji Type
SH-4/G
4 POLE
SH-4
8 POLE
SH-4/G
8 POLE
SH-5
5 POLE
SH-5/G
5 POLE
EXPLANATION OF PART NUMBER SYSTEM
4 S H 4 2 2 #
APPROVAL
4= UL Listed
JIS Approved
OPERATION
S=AC Coil
G=DC Coil
COIL VOLTAGE
Select code from chart on next page
For AC: use Table 1
For DC: use Table 2
DESCRIPTION
QUANTITY OF N.C. AUX. CONTACTS
QUANTITY OF N.O. AUX. CONTACTS
TOTAL NUMBER OF CONTACTS
H=Industrial Relay
iic communication, the host cannot receive relevant data
Problem description: During the master-slave communication process, the host cannot always receive the key value sent when the touch screen is pressed, but can receive the key value sent when it is li...
柯小西 Microchip MCU
280049Solution to the problem of LaunchPad emulator not being able to connect
This time I got a TI official LAUNCHXL-F280049C, the board comes with an XDS110 emulator, 280049 belongs to the Piccolo F28004x series To use F280049C, you need to install a higher version of CCS, bec...
火辣西米秀 DSP and ARM Processors
Commonly used algorithms for drones - Kalman filter (XI)
4.3 Jacobian Matrix The Jacobian matrix is widely used in various occasions. The Jacobian is the differential ratio of the output to the input, indicating the influence of the change (differential) of...
sigma Electronics Design Contest
What is PWM "dead zone"?
PWM is pulse width modulation. In power electronics, the most commonly used are rectification and inversion. This requires the use of rectifier bridges and inverter bridges. For three-phase electricit...
qwqwqw2088 Analogue and Mixed Signal
E-sports data: Design and practice of common analog systems for e-sports based on TI devices - high-speed DAC module design
High-speed DAC module designThe high-speed DAC module includes two circuits: D/A output and signal conditioning. Most of the controlled objects are voltage-controlled, while most high-speed D/A chips ...
Jacktang Electronics Design Contest
How to choose 18650 charging IC?
The battery is a 18650 parallel battery pack as shown in the picture, with a voltage of 4.2V. The maximum charging current is required to be 2A. Is there any suitable charging IC recommended? Is this ...
dianhang Analog electronics

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号