Part Number

Search

4SH431A

Description
Power/Signal Relay, 4PST, Momentary, 10A (Contact), 300VDC (Contact), AC/DC Output, DIN-Rail Mount
CategoryMechanical and electronic products    relay   
File Size219KB,4 Pages
ManufacturerFuji Electric Co., Ltd.
Download Datasheet Parametric View All

4SH431A Overview

Power/Signal Relay, 4PST, Momentary, 10A (Contact), 300VDC (Contact), AC/DC Output, DIN-Rail Mount

4SH431A Parametric

Parameter NameAttribute value
MakerFuji Electric Co., Ltd.
Reach Compliance Codeunknown
ECCN codeEAR99
body width43 mm
body height80 mm
Body length or diameter80 mm
Maximum coil voltage (AC)100 V
Contact (AC) maximum rated R load10A@600VAC
Maximum contact current (AC)10 A
Maximum contact current (DC)10 A
Contact (DC) maximum rated R load10A@300VDC
Maximum contact voltage (AC)600 V
Maximum contact voltage (DC)300 V
Contact/Output Power TypeAC/DC
Electrical life250000 Cycle(s)
Manufacturer's serial number4SH
Installation featuresDIN-RAIL MOUNT
physical size80mm X 43mm X 80mm
GuidelineBS; CSA; IEC, NEMA; UL; VDE
Relay actionMOMENTARY
Relay function4PST
Relay typePOWER/SIGNAL RELAY
surface mountNO
Termination typeSCREW
Base Number Matches1
"ORANGE LINE" INDUSTRIAL RELAY
Features and Ratings
FEATURES
NEW SH SERIES EXPANDABLE INDUSTRIAL RELAY
APPLICATIONS (U.S. Catalog No.4SH and 4GH Series)
High contact reliability that accommodates electronic devices.
All contacts are bifurcated, providing high contact reliability
(minimum operational voltage and current: 5V and 3mA DC)
and enabling direct input to an electronic control circuit.
A wide variety of optional units.
In addition to an auxiliary contact block (two or four poles),
many function units such as a coil surge suppression unit and
terminal covers can be installed on standard industrial relays.
This allows for flexibility and easy modification in the field.
Snap-on mounting on an IEC or DIN rail.
All models can be mounted on an IEC or DIN Standard
35mm rail.
Meets International Standards.
The SH Series industrial relays conform to the following
International Standards: IEC, NEMA, BS and VDE. They are
also UL, CSA, BV and Lloyd approved.
Compatible with conventional models.
SH Series industrial relays are compatible with the
discontinued Fuji SRCa50-3/X, SRCa50-3F/X, and SRC50-05/X
industrial relays. In addition to the mounting holes needed for
the compatibility, mounting holes based on the IEC Standard
are also provided.
Terminal numbers conforming to IEC Standards.
Terminal numbers are based on IEC Standards.
New design.
The arc extinguishing cover is ivory colored with orange
accents, providing a new look to the conventional industrial
relay.
AC OPERATED INDUSTRIAL RELAYS
U.S. Catalog No.
4SH440#
4SH431#
4SH422#
4SH880#
4SH871#
4SH862#
4SH853#
4SH844#
4SH550#
4SH541#
4SH532#
4SH523#
4SH514#
4SH505#
Aux. Contact
4NO
3NO+1NC
2NO+2NC
8NO
7NO+1NC
6NO+2NC
5NO+3NC
4NO+4NC
5NO
4NO+1NC
3NO+2NC
2NO+3NC
1NO+4NC
5NC
Fuji Type
SH-4
4 POLE
DC OPERATED INDUSTRIAL RELAYS
U.S. Catalog No.
4GH440#
4GH431#
4GH422#
4GH880#
4GH871#
4GH862#
4GH853#
4GH844#
4GH550#
4GH541#
4GH532#
4GH523#
4GH514#
4GH505#
Aux. Contact
4NO
3NO+1NC
2NO+2NC
8NO
7NO+1NC
6NO+2NC
5NO+3NC
4NO+4NC
5NO
4NO+1NC
3NO+2NC
2NO+3NC
1NO+4NC
5NC
Fuji Type
SH-4/G
4 POLE
SH-4
8 POLE
SH-4/G
8 POLE
SH-5
5 POLE
SH-5/G
5 POLE
EXPLANATION OF PART NUMBER SYSTEM
4 S H 4 2 2 #
APPROVAL
4= UL Listed
JIS Approved
OPERATION
S=AC Coil
G=DC Coil
COIL VOLTAGE
Select code from chart on next page
For AC: use Table 1
For DC: use Table 2
DESCRIPTION
QUANTITY OF N.C. AUX. CONTACTS
QUANTITY OF N.O. AUX. CONTACTS
TOTAL NUMBER OF CONTACTS
H=Industrial Relay
How can LM3447 achieve constant power control?
[b][size=4]Question: [/size][/b] [size=4]I have read the PDF of LM3447 3-4 times, but I cannot figure out how to achieve constant power control. Actually, the idea of Ti or NS is very good. [/size] [s...
qwqwqw2088 Analogue and Mixed Signal
【Nucleo G071 Review】 Final Conclusion
[size=5] The final project was used in conjunction with the QT host computer program. The host computer program uses serial port communication. The principle is similar to the serial port assistant. I...
donatello1996 stm32/stm8
Differences between CPU and CLA and Error Handling Techniques
The C2000 microprocessor with C28x+FPU architecture adds some registers and instructions to the original C28x fixed-point CPU to support IEEE single-precision floating-point operations. For programs w...
Jacktang DSP and ARM Processors
WeChat applet Bluetooth communication
WeChat Mini Programs currently only support Bluetooth Low Energy (BLE) and not classic Bluetooth. According to actual tests, the latest version of WeChat Mini Program has good support for IOS, but ver...
Jacktang Wireless Connectivity
Automobile crankshaft dynamic balance problem-N600
[align=left][font=宋体]The staff is inspecting the journal. Due to the complex stress on the journal, its wear is uneven. It is worn into an ellipse along the radial direction and a cone along the axial...
missu11 Automotive Electronics
PD fast charging technology has been significantly updated, USB PD3.1 has been released, supporting 48V and 240W output
Recently, the USB PD3.0 fast charging standard has been upgraded. The new USB PD3.1 fast charging standard will support a maximum voltage output of 48V, and the charging power will be increased to 240...
Legendary008 Domestic Chip Exchange

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号