Green Laser Diode in TO56 Package
Version 1.1
PLT5 510
Features
•
Optical output power (continuous wave): 10 mW (T
case
= 25 °C)
•
Typical emission wavelength: 515 nm
•
Efficient radiation source for cw and pulsed operation
•
Single transverse mode semiconductor laser
•
High modulation bandwidth
•
TO56 package with photo diode
Applications
•
Laser projection
•
Laser shows
•
Presenter
•
Biomedical Applications
•
Metrology
Safety Advice
Depending on the mode of operation, these devices emit highly concentrated visible light which can be
hazardous to the human eye. Products which incorporate these devices have to follow the safety
precautions found in IEC 60825-1 “Safety of laser products”.
ATTENTION – Observe Precautions For Handling – Electrostatic Sensitive Device
04.04.2016
1
Version 1.1
Ordering Information
Type:
PLT5 510_B1-3
Optical Output Power
P
opt
(T
case
=
25°C)
10 mW
Q65111A6310
Ordering Code
PLT5 510
Maximum Ratings
Operation outside these conditions may damage the device. Operation at the maximum ratings influences
lifetime.
Parameter
Operating Current
Operating Temperature
Storage Temperature
Reverse Voltage
Soldering Temperature max. 10 sec.
Junction temperature
Laser Characteristics
(T
case
= 25 °C)
Parameter
Symbol
min.
I
F
T
case
T
stg
V
R
T
solder
T
j
-20
-40
Values
max.
120
+60
+85
2
260
120
mA
°C
°C
V
°C
°C
Unit
Symbol
min.
B1
B2
B3
λ
peak
510
515
520
–
–
–
–
5x
19
–
–
–
–
Values
typ.
–
–
–
2
30
60
5.4
6.6 x
21.4
100:1
>100
34
150
max.
515
520
530
–
60
100
7.0
9x
25
–
–
–
–
Unit
nm
Emission Wavelength
1)
Spectral Width (FWHM)
1)
Threshold Current
Operating Current
1)
Operating Voltage
1)
Δλ
I
th
I
F
V
F
θ
∥
x
θ
⊥
P
gr
f
R
th
I
m
nm
mA
mA
V
deg
Beam Divergence (FWHM)
1)
Polarization
1)
Modulation Frequency
Thermal resistance (junction to case)
Monitor current
1)
2)
MHz
K/W
µA
1) 2)
Standard operating conditions refer to a continuous wave output power of
P
opt
= 10 mW.
Photo current refers to a reverse voltage of
V
R
= 5 V.
04.04.2016
2