capacitors are specifically designed for interference-sup-
pression AC line filtering applications. Having internation-
ally recognized safety certifications, these capacitors are
well-suited for applications that require keeping potentially
disruptive or damaging line transients and EMI out of sus-
ceptible equipment. They are also an ideal solution when
needing to suppress line disturbances at the source.
Safety Certified Capacitors are classified as either X and/
or Y capacitors. Class X capacitors are primarily used in
line-to-line (across-the-line) applications. In this applica-
tion, there is no danger of electric shock to humans should
the capacitor fail, but could result in a risk of fire. The class
Y capacitor is primarily used in line-to-ground (line by-pass)
applications. In this application, failure of the capacitor
could lead to danger of electric shock.
With a working voltage of 440 VAC in line-to-line (Class X)
and 300 VAC in line-to-ground (Class Y) applications, these
safety capacitors meet the impulse test criteria outlined in
IEC Standard 60384. Meeting subclass X1 and Y2 require-
ments, these devices are certified to withstand impulses up
to 4 KV (X1) and 5 KV (Y2) respectively. These encapsulated
devices also meet the flame test requirements outlined in UL
Standard 94V–0.
Click image above for interactive 3D content
Ordering Information
C9
Ceramic
Series
C9 =
Ceramic
900
Series
Open PDF in Adobe Reader for full functionality
7
Body
Diameter
0 = 7.0 mm
1 = 8.0 mm
2 = 9.0 mm
3 = 10.0 mm
4 = 11.0 mm
6 = 13.0 mm
8 = 15.0 mm
1
Lead
Spacing
1,2,4
7 = 7.5 mm
1 = 10.0
mm
U
Spec.
U=
Safety
472
M
Z
W
D
A
Lead
Config.
1,3,4
A = Straight
B = Vertical
Kink
C = Outside
Kink
D = Inside
Kink
A
Failure
Rate
A=
N/A
7317
Packaging
(C-Spec)
See
"Packaging
C-Spec
Ordering
Options
Table"
below
Capacitance Capacitance
Code (pF)
Tolerance
Two
significant
digits and
number of
zeroes
J = ±5%
K = ±10%
M = ±20%
Rated
Dielectric/
Design
Voltage Temp. Char.
Z = X1
440 VAC
/Y2 300
VAC
S = SL
Y = Y5P
W = Y5U
V = Y5V
D=
Disc
Due to a high risk of arcing, "Inside Kink" lead configuration cannot be combined with the 5 mm lead spacing option. The "Inside Kink" option is only
available on capacitors with lead spacing of 7.5 mm or greater. A potential for arcing may exist when combining the "Inside Kink" lead configuration
with a 7.5mm lead spacing option, especially in high humidity environments and/or when exposure to voltages and transients may impact creepage and
clearance requirements.
2
Capacitor body diameter will limit available lead spacing and packaging options. See "Dimensions" and "Product Ordering Codes and Ratings" sections
of this document to determine availability.
3
"Vertical Kink", "Outside Kink" and "Inside Kink" lead configurations cannot be combined with the bulk/20 mm lead length option (WL20). 20 mm lead
length is only available on capacitors with straight leads (lead configuration ordering code "A"). For nonstandard lead length inquiries, please contact
KEMET.
4
Bulk packaging lead length availability is dependent upon "Lead Configuration" and "Lead Spacing." See "Dimensions" section of this document to
verify availability of a specific lead length option. For nonstandard lead length inquiries, please contact KEMET.
Safety Standard Recognized, C900, Encapsulated, AC Type, X1 440 VAC/Y2 300 VAC (Industrial Grade)
Packaging C-Spec Ordering Options Table
Packaging Type
Ammo Pack
Lead Length
(mm)
2,3
20.0+1.5/−1.0 (straight leads)
18.0+2.0/−0 (preformed leads
1
)
3.0±1.0
3.5±1.0
4.0±1.0
4.5±1.0
5.0±1.0
20.0 minimum
4
Packaging
Ordering Code (C-Spec)
7317
WL30
WL35
WL40
WL45
WL50
WL20
Bulk Bag
Preformed (crimped) lead configurations include vertical kink, outside kink and inside kink. See "Lead Configurations" and "Ordering Information"
sections of this document for further details.
2
"Vertical Kink", "Outside Kink" and "Inside Kink" lead configurations cannot be combined with the bulk/20 mm lead length option (WL20). 20 mm lead
length is only available on capacitors with straight leads (lead configuration ordering code "A"). For nonstandard lead length inquiries, please contact
KEMET.
3
For nonstandard lead length inquiries, please contact KEMET.
4
Lead length of 20.0 mm minimum only available for straight leads.
1
Benefits
•
•
•
•
•
•
•
•
•
•
•
•
Safety standard recognized (IEC 60384–14)
Reliable operation up to 125°C
Class X1/Y2
7.5 mm and 10 mm lead spacing
Lead (Pb)-free and RoHS Compliant
Halogen-free
Capacitance offerings ranging from 10 pF up to 10 nF
Available capacitance tolerances of ±5%, ±10% and ±20%
High reliability
Preformed (crimped) or straight lead configurations
Safety Standard Recognized, C900, Encapsulated, AC Type, X1 440 VAC/Y2 300 VAC (Industrial Grade)
Table 1 – Product Ordering Codes and Ratings
Dielectric/
Temp.
Char.
Dimensions (mm)
KEMET
Part Number
C90(1)U100JZSD(2)A(3)
C90(1)U120JZSD(2)A(3)
C90(1)U150JZSD(2)A(3)
C90(1)U180JZSD(2)A(3)
C90(1)U200JZSD(2)A(3)
C90(1)U220JZSD(2)A(3)
C90(1)U240JZSD(2)A(3)
C90(1)U270JZSD(2)A(3)
C90(1)U300JZSD(2)A(3)
C90(1)U330JZSD(2)A(3)
C90(1)U360JZSD(2)A(3)
C90(1)U390JZSD(2)A(3)
C90(1)U470JZSD(2)A(3)
C90(1)U500JZSD(2)A(3)
C90(1)U510JZSD(2)A(3)
C91(1)U560JZSD(2)A(3)
C91(1)U620JZSD(2)A(3)
C91(1)U680JZSD(2)A(3)
C91(1)U750JZSD(2)A(3)
C92(1)U820JZSD(2)A(3)
C93(1)U101JZSD(2)A(3)
C90(1)U101KZYD(2)A(3)
C90(1)U151KZYD(2)A(3)
C90(1)U221KZYD(2)A(3)
C90(1)U331KZYD(2)A(3)
C90(1)U471KZYD(2)A(3)
C91(1)U561KZYD(2)A(3)
C91(1)U681KZYD(2)A(3)
C92(1)U821KZYD(2)A(3)
C92(1)U102KZYD(2)A(3)
C90(1)U102MZWD(2)A(3)
C92(1)U152MZWD(2)A(3)
C92(1)U222MZWD(2)A(3)
C94(1)U332MZWD(2)A(3)
C96(1)U392MZWD(2)A(3)
C96(1)U472MZWD(2)A(3)
C90(1)U102MZVD(2)A(3)
C90(1)U152MZVD(2)A(3)
C90(1)U222MZVD(2)A(3)
C92(1)U332MZVD(2)A(3)
C94(1)U392MZVD(2)A(3)
C94(1)U472MZVD(2)A(3)
C96(1)U682MZVD(2)A(3)
C98(1)U103MZVD(2)A(3)
KEMET Part Number
Lead Spacing
Lead
Diameter
Bulk
Packaging
Ammo
Packaging
Capacitance
10 pF
12 pF
15 pF
18 pF
20 pF
22 pF
24 pF
27 pF
30 pF
33 pF
36 pF
39 pF
47 pF
50 pF
51 pF
56 pF
62 pF
68 pF
75 pF
82 pF
100 pF
100 pF
150 pF
220 pF
330 pF
470 pF
560 pF
680 pF
820 pF
1,000 pF
1,000 pF
1,500 pF
2,200 pF
3,300 pF
3,900 pF
4,700 pF
1,000 pF
1,500 pF
2,200 pF
3,300 pF
3,900 pF
4,700 pF
6,800 pF
10,000 pF
Capacitance
Capacitance
Tolerance
Body
Diameter
(Maximum)
Body
Thickness
(Maximum)
7.0
7.5 mm
or
10 mm
SL
±5%
5.0
0.55 ±0.1
8.0
9.0
10.0
7.0
±10%
8.0
9.0
7.0
±20%
9.0
11.0
13.0
5.0
0.55 ±0.1
7.5 mm
or
10 mm
5.0
0.55 ±0.1
7.5 mm
or
10 mm
Y5P
Y5U
7.0
±20%
9.0
11.0
13.0
15.0
Capacitance
Tolerance
Body Diameter
(Maximum)
Body Thickness
(Maximum)
Lead Diameter
Lead Spacing
5.0
0.55 ±0.1
7.5 mm
or
10 mm
Y5V
(1) To properly complete ordering code, insert the one-digit numeric code to reflect required lead spacing: (Note that select capacitance values and
packaging options may limit lead spacing availability. See table above to verify availability.)
7 = 7.5 mm
1 = 10.0 mm
(2) To properly complete ordering code, insert the one-digit character code to reflect the required lead configuration: (See "Lead Configuration" section
of this document, page 2, for further details.)
A = Straight
B = Vertical Kink
C = Outside Kink
D = Inside Kink
(3) To properly complete ordering code, enter the four-digit numeric or alphanumeric "Packaging C-Spec Ordering Code." See "Dimensions" section of
When developing an embedded system, one of the options is to base the computing hardware on a microcontroller rather than a microprocessor MPU. Both approaches have their appeal, but generally they wi...
[i=s]This post was last edited by Tronlong Team on 2020-9-21 16:55[/i]CMOS camera test
The CMOS camera module used in this section is Tronlong's TL2659, which captures and displays video through the C...
Texas Instruments recently launched a solution to use Ethernet to power the industrial market, which really refreshed everyone's cognition. In fact, power supply in some environments is indeed a probl...
The wiring schematic diagram of the three-phase four-wire active energy meter with current transformer, current meter and voltage transformer: The three transformers S1 are connected to meters 1, 4 a...
How to export the data of mems sensor for programming data processing and calculation, and how to export and calculate the quaternion data measured by sensorfusion. I mean real-time data calculation, ...
Experiment name: Research on vibration-driven rotating and climbing soft robots
Research direction: Using the vibration drive principle, two soft drive structures that can achieve rapid rotation and c...
I/O Port Layout
All I/O ports of the STC2C5201AD series microcontrollers can be configured by software to one of four working types, as shown in the following table. The four types are: qu...[Details]
SmartConfig Now when we buy a lot of smart devices, we need to connect them to the Internet, but they don’t have any effective input methods, such as keyboards and screens. So the so-called one-click...[Details]
AAPCS defines some standards for the ARM architecture. Here we only focus on the function call part. As shown in Figure 8, AAPCS defines the R0~R15 registers of ARM and clarifies their responsibiliti...[Details]
At present, unlisted inverter companies are accelerating their pace, and listed inverter companies are actively expanding production and increasing volume to increase market share.
Benefit...[Details]
In order to fully support the orderly resumption of work and production of Tibetan enterprises, State Grid Tibet Electric Power Co., Ltd. has introduced a phased policy to reduce electricity costs....[Details]
Former Microsoft executive joins RPA industry firm UiPath to accelerate widespread adoption of automation in the region
Beijing, April 7, 2022 - UiPath, an enterprise automation soft...[Details]
Frequency characteristics are the response characteristics of a system (or component) to input signals of different frequencies, and are one of the most important characteristics of a network. The ...[Details]
The core element of pure electric vehicles is the battery, which not only determines the vehicle's range but also affects the safety of daily use. However, no matter how long the range is, it cannot ...[Details]
1. What principle does the density meter use? Density meter The weight of an object pulls it toward the ground, but if you place the object in a liquid, a force called buoyancy acts in the opposite d...[Details]
Affected by the overall slowdown of the global consumer electronics market and the Sino-US trade war, the MCU market has shrunk after two years of high prosperity. Unlike the global MCU market, under...[Details]
This morning, Huawei Investment Holding Co., Ltd. announced its decision to sell the entire Honor business assets to Shenzhen Zhixin New Information Technology Co., Ltd. After the transaction, Huawei...[Details]
Think of a passenger car as a collection of electronic control units (ECUs) spread across the length and width of the car, using different networks to talk to each other. When more advanced automotiv...[Details]
Abstract: With the continuous improvement of living standards, cars have gradually entered thousands of households. The pursuit of fashion and individuality has made car owners do their best to dress ...[Details]
High voltage differential probe is a kind of probe. Differential probe is an oscilloscope probe designed using the differential amplification principle. It is mainly used to observe differential sign...[Details]
Analysis of LCD working principle:
1. LCD hardware architecture:
LCD hardware system: You can see that the LCD controller is in the ARM processor, and the LCD screen and p...[Details]