Part Number

Search

VI-J3H-EX-B1

Description
Isolated DC/DC Converters VI J00/200 - 48 Vin, 52 Vout, 75 W, E Product Grade
CategoryPower/power management    The power supply circuit   
File Size655KB,8 Pages
ManufacturerVICOR
Websitehttp://www.vicorpower.com/
Download Datasheet Parametric View All

VI-J3H-EX-B1 Online Shopping

Suppliers Part Number Price MOQ In stock  
VI-J3H-EX-B1 - - View Buy Now

VI-J3H-EX-B1 Overview

Isolated DC/DC Converters VI J00/200 - 48 Vin, 52 Vout, 75 W, E Product Grade

VI-J3H-EX-B1 Parametric

Parameter NameAttribute value
Is it Rohs certified?incompatible
MakerVICOR
Reach Compliance Codenot_compliant
Other featuresREMOTE SHUTDOWN
Analog Integrated Circuits - Other TypesDC-DC REGULATED POWER SUPPLY MODULE
CertificationTUV, UL
Efficiency (main output)88%
high27.4 mm
Maximum input voltage60 V
Minimum input voltage42 V
Nominal input voltage48 V
JESD-609 codee0
length61 mm
Maximum grid adjustment rate0.2%
Maximum load regulation0.2%
Maximum operating temperature100 °C
Minimum operating temperature-10 °C
Terminal surfaceTin/Lead (Sn/Pb)
Maximum total power output75 W
width57.9 mm
Half Brick, DC-DC Converters
VI-J00
VE-J00
®
S
C
US
C
NRTL
US
25 to 100 Watts
Features & Benefits
Isolated output
Up to 50W/in
3
cURus, cTÜVus
CE Marked
Up to 90% efficiency
Size: 2.28” x 2.4” x 0.5”
(57,9 x 61,0 x 12,7mm)
Remote sense and current limit
Logic disable
Wide range output adjust
ZCS power architecture
Low noise FM control
RoHS compliant (VE verisons)
Product Highlights
The VI-J00 MiniMod family established a new standard in component-level DC-DC
converters. This “junior” size complement to the higher power VI-200 family offers up
to 100W of isolated and regulated power in a board mounted package. With thousands
of input/output/power combinations, and with a maximum operating temperature
rating of 100°C, the MiniMod provides nearly unlimited flexibiliy for power system
designers to meet demanding time to market requirements.
Utilizing Vicor’s “zero-current-switching” forward converter technology, proven
by an installed base of over 8 million units, the MiniMod family combines state of
the art power density with the efficiency, low noise and reliability required by next
generation power systems.
Part Numbering
VI
J
6
1
C
W
Family
VI
=Non-RoHS
VE
= RoHS
Series
J
= J00
0
= 12V
V
= 24V
1
= 24V
W
= 24V
2
= 36V
3
= 48V
Input
N
= 48V
4
= 72V
T
= 110V
5
= 150V
6
= 300V
7
= 150/300V
Z
= 2V
Y
= 3.3V
0
= 5V
X
= 5.2V
W
= 5.5V
V
= 5.8V
T
= 6.5V
R
= 7.5V
Output
M
= 10V
1
= 12V
P
= 13.8V
2
= 15V
N
= 18.5V
3
= 24V
L
= 28V
J
= 36V
K
= 40V
4
= 48V
H
= 52V
F
= 72V
D
= 85V
B
= 95V
Grade
E
= –10 to 100°C
I
= – 40 to 100°C
M
= –55 to 100°C
≥ 5V
Power
< 5V
W
= 20A
X
= 15A
Y
= 10A
Z
= 5A
C
= –25 to 100°C
W
= 100W
X
= 75W
Y
= 50W
Z
= 25W
Note:
For additional
packaging options,
please see page 5.
VI-J00 DC-DC Converters
Page 1 of 7
Rev 3.0
06/2017
TI Embedded Live Month - Registration starts now to support efficient, intelligent and low-power system design~
TI Embedded Live Month - Registration starts now to support efficient, intelligent and low-power system design~Click here to participate in the eventLive Broadcast IntroductionLive broadcast time Live...
EEWORLD社区 TI Technology Forum
Four input modes of MCU
MCU input modes include floating, pull-up, pull-down, and analog input. If the pull-up or pull-down mode is used for input, wouldn't it force the real signal to become the power supply VCC or GND? In ...
QWE4562009 MCU
How to replace TMS320C6416TGLZ7 chip
Can TMS320C6416TGLZ7 be replaced pin to pin with TMS320C6416TBGLZ7 or TMS320C6416TBCLZ7?They can be used interchangeably. For the difference, please refer to:e2echina.ti.com/.../73254Thank you very mu...
灞波儿奔 DSP and ARM Processors
I would like to ask how to connect the ground on the PCB board of the monitoring equipment and the board ground?
I am currently designing an outdoor device, powered by 24V, with 4 external sensors. The sensors need to be buried underground. Each sensor has 2 signal lines, a ground line, and a shield line. The de...
天天1 Analog electronics
Overvoltage, overcurrent and overtemperature detection circuit
The input voltage of a power module is 24VDC (ranging from 20 to 26V), and the rated output voltage and current is 12VDC/50A. Now we design an output overvoltage, overcurrent and overtemperature alarm...
洗洗睡 Analog electronics
Recruitment: Assistant Optical Engineer, Assistant Electronic Engineer, Assistant CAE Engineer, Assistant Structural Engineer
Recruitment: Assistant Optical Engineer (3) people, bachelor's degree, more than 1 year of work experience 1. Understand the standards of the automotive industry, familiar with the standards of electr...
解优人才网 Talking about work

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号