AC-DC Power Supplies PCB Mount type
Ordering information
YS5
R
Y
1
2
S
3
5
05A
4
1Series
name
2Single
output
3Output
wattage
4Output
voltage
MODEL
MAX OUTPUT WATTAGE[W]
DC OUTPUT
YS505A
5.0
5V 1.0A
YS512A
5.4
12V 0.45A
SPECIFICATIONS
MODEL
VOLTAGE[V]
ACIN 100V
CURRENT[A]
FREQUENCY[Hz]
EFFICIENCY[%] ACIN 100V
INRUSH CURRENT[A] ACIN 100V
VOLTAGE[V]
CURRENT[A]
LINE REGULATION[mV]
LOAD REGULATION[mV]
*
1
RIPPLE[mVp-p]
RIPPLE NOISE[mVp-p]
*
1
TEMPERATURE REGULATION[mV] 0 to +55
C
START-UP TIME[ms]
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
OUTPUT VOLTAGE SETTING[%]
HOLD-UP TIME[ms]
OVERCURRENT PROTECTION
INPUT-FG, OUTPUT
OUTPUT-FG
OPERATING TEMP.,HUMID.AND ALTITUDE
STORAGE TEMP.,HUMID.AND ALTITUDE
VIBRATION
IMPACT
AGENCY APPROVALS
CONDUCTED NOISE
YS505A
AC85 - 132 1
f
or DC110 - 170
0.15typ (Io=100%)
47 - 440 or DC
68typ (Io=100%)
15typ (Io=100%)
YS512A
INPUT
70typ (Io=100%)
OUTPUT
Y
PROTECTION
CIRCUIT
ISOLATION
ENVIRONMENT
SAFETY AND
NOISE
REGULATIONS
5
12
1
0.45
20max
48max
40max
100max
80max
120max
120max
150max
50max
150max
200max (ACIN 85V, Io=100%)
Fixed
t
5max (Rated input/output, Ta=25
C
)
10typ (ACIN 85V, Io=100%)
Works over 105% of rating and recovers automatically
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50M
W
min (At Room Temperature)
AC500V 1minute, Cutoff current = 100mA, DC500V 50M
W
min (At Room Temperature)
-10 to +70
C
, 20 - 95%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000feet) max
-20 to +75
C
, 20 - 95%RH (Non condensing), 9,000m (30,000feet) max
10 - 55Hz, 98.0m/s
2
(10G), 3minutes period, 30minutes each along X, Y and Z axis
490.3m/s
2
(50G), 11ms, once each X, Y and Z axis
UL60950-1, C-UL
Complies with FCC-B
*1
Measured by 20MHz oscilloscope.
*
Parallel operation with other model is not possible.
Y-2
YS5
External view
Performance data
¡
STATIC CHARACTERISTICS (YS512A)
¡
RISE TIME & FALL TIME (YS512A)
20ms/DIV
Y
¡
OVERCURRENT CHARACTERISTICS (YS512A)
¡
DERATING CURVE
Y-3
AC-DC Power Supplies PCB Mount type
Ordering information
YS10
R
Y
1
2
S
3
10
05A
4
1Series
name
2Single
output
3Output
wattage
4Output
voltage
MODEL
MAX OUTPUT WATTAGE[W]
DC OUTPUT
YS1005A
10.0
5V 2.0A
YS1012A
10.8
12V 0.9A
SPECIFICATIONS
MODEL
VOLTAGE[V]
ACIN 100V
CURRENT[A]
FREQUENCY[Hz]
EFFICIENCY[%] ACIN 100V
INRUSH CURRENT[A] ACIN 100V
VOLTAGE[V]
CURRENT[A]
LINE REGULATION[mV]
LOAD REGULATION[mV]
*
1
RIPPLE[mVp-p]
RIPPLE NOISE[mVp-p]
*
1
TEMPERATURE REGULATION[mV] 0 to +55
C
START-UP TIME[ms]
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
OUTPUT VOLTAGE SETTING[%]
HOLD-UP TIME[ms]
OVERCURRENT PROTECTION
INPUT-FG, OUTPUT
OUTPUT-FG
OPERATING TEMP.,HUMID.AND ALTITUDE
STORAGE TEMP.,HUMID.AND ALTITUDE
VIBRATION
IMPACT
AGENCY APPROVALS
CONDUCTED NOISE
YS1005A
AC85 - 132 1
f
or DC110 - 170
0.3typ (Io=100%)
47 - 440 or DC
73typ (Io=100%)
15typ (Io=100%)
YS1012A
INPUT
75typ (Io=100%)
OUTPUT
Y
PROTECTION
CIRCUIT
ISOLATION
ENVIRONMENT
SAFETY AND
NOISE
REGULATIONS
5
12
2
0.9
20max
48max
40max
100max
80max
120max
120max
150max
50max
150max
200max (ACIN 85V, Io=100%)
Fixed
t
5max (Rated input/output, Ta=25
C
)
10typ (ACIN 85V, Io=100%)
Works over 105% of rating and recovers automatically
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50M
W
min (At Room Temperature)
AC500V 1minute, Cutoff current = 100mA, DC500V 50M
W
min (At Room Temperature)
-10 to +70
C
, 20 - 95%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000feet) max
-20 to +75
C
, 20 - 95%RH (Non condensing), 9,000m (30,000feet) max
10 - 55Hz, 98.0m/s
2
(10G), 3minutes period, 30minutes each along X, Y and Z axis
490.3m/s
2
(50G), 11ms, once each X, Y and Z axis
UL60950-1, C-UL
Complies with FCC-B
*1
Measured by 20MHz oscilloscope.
*
Parallel operation with other model is not possible.
Y-4
YS10
External view
Performance data
¡
STATIC CHARACTERISTICS (YS1012A)
¡
RISE TIME & FALL TIME (YS1012A)
20ms/DIV
Y
¡
OVERCURRENT CHARACTERISTICS (YS1012A)
¡
DERATING CURVE
Y-5
AC-DC Power Supplies PCB Mount type
Ordering information
YS15
R
Y
1
2
S
3
15
05A
4
1Series
name
2Single
output
3Output
wattage
4Output
voltage
MODEL
MAX OUTPUT WATTAGE[W]
DC OUTPUT
YS1505A
15.0
5V 3.0A
YS1512A
15.6
12V 1.3A
SPECIFICATIONS
MODEL
VOLTAGE[V]
ACIN 100V
CURRENT[A]
FREQUENCY[Hz]
EFFICIENCY[%] ACIN 100V
INRUSH CURRENT[A] ACIN 100V
VOLTAGE[V]
CURRENT[A]
LINE REGULATION[mV]
LOAD REGULATION[mV]
*
1
RIPPLE[mVp-p]
RIPPLE NOISE[mVp-p]
*
1
TEMPERATURE REGULATION[mV] 0 to +55
C
START-UP TIME[ms]
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
OUTPUT VOLTAGE SETTING[%]
HOLD-UP TIME[ms]
OVERCURRENT PROTECTION
INPUT-FG, OUTPUT
OUTPUT-FG
OPERATING TEMP.,HUMID.AND ALTITUDE
STORAGE TEMP.,HUMID.AND ALTITUDE
VIBRATION
IMPACT
AGENCY APPROVALS
CONDUCTED NOISE
YS1505A
AC85 - 132 1
f
or DC110 - 170
0.4typ (Io=100%)
47 - 440 or DC
75typ (Io=100%)
25typ (Io=100%)
YS1512A
INPUT
78typ (Io=100%)
OUTPUT
Y
PROTECTION
CIRCUIT
ISOLATION
ENVIRONMENT
SAFETY AND
NOISE
REGULATIONS
5
12
3
1.3
20max
48max
40max
100max
80max
120max
120max
150max
50max
150max
200max (ACIN 85V, Io=100%)
Fixed
t
5max (Rated input/output, Ta=25
C
)
10typ (ACIN 85V, Io=100%)
Works over 105% of rating and recovers automatically
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50M
W
min (At Room Temperature)
AC500V 1minute, Cutoff current = 100mA, DC500V 50M
W
min (At Room Temperature)
-10 to +70
C
, 20 - 95%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000feet) max
-20 to +75
C
, 20 - 95%RH (Non condensing), 9,000m (30,000feet) max
10 - 55Hz, 98.0m/s
2
(10G), 3minutes period, 30minutes each along X, Y and Z axis
490.3m/s
2
(50G), 11ms, once each X, Y and Z axis
UL60950-1, C-UL
Complies with FCC-B
*1
Measured by 20MHz oscilloscope.
*
Parallel operation with other model is not possible.
Y-6