Basic information of INA118U-TR amplifier:
INA118U-TR is an INSTRUMENTATION AMPLIFIER.
INA118U-TR amplifier core information:
The minimum operating temperature of INA118U-TR is -40 °C and the maximum operating temperature is 85 °C. Its maximum average bias current is 0.01 µA and its maximum input offset current (IIO) is only 0.01 µA
How to simply check the efficiency of an amplifier? Looking at its slew rate, the INA118U-TR has a nominal slew rate of 0.9 V/us. Its maximum voltage gain is 10000 and its minimum voltage gain is 1. When the op amp is used in closed loop, at a certain closed-loop gain (usually 1 or 2, 10, etc.), the frequency when the INA118U-TR gain becomes 0.707 times the low-frequency gain is 0.8 MHz.
The nominal supply voltage of INA118U-TR is 15 V, and its corresponding nominal negative supply voltage is -15 V. The input offset voltage of INA118U-TR is 1125 µV (input offset voltage: the compensation voltage added between the two input terminals to make the output terminal of the operational amplifier 0V (or close to 0V).)
Related dimensions of INA118U-TR:
INA118U-TR has 8 terminals. Its terminal position type is: DUAL.
INA118U-TR amplifier additional information:
Its temperature grade is: INDUSTRIAL. The corresponding JESD-30 code is: R-PDSO-G8. The package code of INA118U-TR is: SOP. INA118U-TR packaging materials are mostly PLASTIC/EPOXY. The package shape is RECTANGULAR.
INA118U-TR package pin formats are: SMALL OUTLINE. Its terminal forms are: GULL WING.