Staircase and corridor light automatic control circuit
Source: InternetPublisher:aerobotics Keywords: BSP lighting electric lamp Updated: 2021/10/14
The circuit is shown in Figure 2-50. This circuit uses field effect
tubes, and through the clever cooperation of electronic components, it forms a unique lighting automatic controller. The lights are not turned off when working informally
, but the light is dim. This is needed in some situations. At the same time, this can also greatly extend the service life of the lighting lamp ,
because before the lamp is fully lit, the filament has a greater resistance than the cold filament, thus avoiding the impact of large current when the lamp
is connected to the power grid
. The delay time is determined by Ci and Ri. If the value shown in Figure 2-50 is used, it is approximately 6 minutes.
In order to disconnect the automatic controller and enhance the light, for example when cleaning the stairs, the switch SA can be turned to the "off" position. At this time, the full grid voltage will be applied to
the lamp .
- Fire safety evacuation emergency signs
- IR2153 emergency fluorescent lamp circuit diagram
- Practical sensitive light-controlled switch circuit diagram
- Resistor value selection circuit
- Power outage emergency lighting
- SC3071 touch step dimming light circuit
- Lighting audio control circuit
- Application circuit of CAT3606
- Electronic rapid starter for fluorescent lamps
- Reverse polarity drive circuit
- Voice controlled flash LED light circuit diagram
- Inpatient pager circuit
- soil content measurement circuit
- Agricultural spraying and insecticide control circuit
- Diode Balanced Mixer Circuit
- ring amplitude modulation circuit
- Series crystal oscillator
- OTL low frequency power amplifier circuit
- common emitter amplifier circuit
- Voltage-controlled voltage source second-order band-pass filter circuit