T3/E3 protection circuit and solution
Source: InternetPublisher:闪电杰克 Keywords: Protection Circuit Updated: 2024/10/24
Interface parameters
Signal rate: 34.368Mbit/s±20ppm
Load impedance: 75Ω
Signal level: 1.0V
Empty number level: 0V±0.1V
The signal transmission rate of T3/E3 is relatively high, so it should be protected by a TVS with low junction capacitance. The device selected is LC03-6. There is no common-mode protection device in the figure. The main reason is that the interface circuit is isolated by a transformer. The insulation withstand voltage of the primary and secondary sides of the transformer can generally reach 1500VAC, which can effectively suppress external common-mode overvoltage.
The transmission distance of the T3/E3 interface is within 50 meters, and the cable is generally not pulled outdoors. However, in some low-end routers, the application environment is relatively harsh, and the cable may be pulled from one room along the outdoor wall to another room. In this case, the protection energy should be considered to be greater.
The shielding layer of the coaxial cable is reliably connected to the housing, that is, it is grounded. At this time, the external overvoltage and overcurrent are reflected in the form of differential mode, so only differential mode protection is performed. The front stage needs to add a diode gas discharge tube N81-A90, the back stage uses SLVU2.8-4, and the middle stage uses a surge protection resistor 2.2Ω/2W resistor for decoupling.
- Replace the GE LOGIQ a200 ultrasound measurement key with a self-made touch switch
- Controlling stepper motors with wireless remote control transceiver and PE-51 board
- One-way rotation circuit of motor controlled by contactor
- Design and principle analysis of practical electric curtain remote control device
- Design and production of wireless multi-location control switch circuit
- Electric vehicle battery charging protection circuit
- Homemade short circuit alarm device
- Night dog barking anti-theft reminder circuit
- Automatic power off switch when power outage occurs
- CD4017 simple and easy to make zero-crossing power regulation circuit
- Relay fixed time overcurrent protection circuit a
- Relay protection circuit a
- Three-phase motor phase failure transistor protection circuit
- Asynchronous motor protection circuit composed of photoelectric coupler
- AC electronic voltage regulator overvoltage protection circuit
- Overcurrent protection circuit for TH78H5 adjustable integrated voltage regulator power supply
- Thyristor overcurrent protection circuit 2
- Thyristor overcurrent protection circuit one b
- Mains overvoltage protection circuit
- Alarm and protection circuit using operational amplifier