Electric energy measurement circuit b
Source: InternetPublisher:supremeOne Keywords: Electric energy measurement BSP current transformer Updated: 2021/10/25
An electric energy meter is an instrument that measures electrical energy. Electric energy meter is available. To measure AC electric energy, DC electric energy can also be measured. tE tI Electric meters that measure AC electric energy
can be divided into two types of meters that measure active electric energy and reactive electric energy. Electric energy meters that measure active electric energy can be divided into two types: single-phase and three-phase electric energy meters. .
Measuring circuit of single-phase active electric energy meter,
1) Requirements for single-phase active electric energy meter measurement wiring:
① Before wiring, check whether the model and specifications of the electric energy meter are suitable for the load. The rated voltage of the electric energy meter should not be lower than the power supply voltage, and the rated
current should not be lower than the load current. When distributing a current transformer , it should not be less than the secondary maximum load current of the transformer.
② The connecting wires of the electric energy meter must use single-strand insulated copper wires. For the current loop, the cross-sectional area of the wires is not less than 2. 5mmz, and
the cross-sectional area of the voltage loop wires is not less than 1. 5mmz:
③ The wires connecting the electric energy meter and other components , no joints are allowed in the middle.
④The neutral line should be connected from one terminal of the electric energy meter and then taken out from the other terminal.
⑤The switch and fuse should be connected to the load side of the energy meter. @When wiring
, pay attention to the polarity of the electric ship meter, that is ,
the voltage coil and current coil marked "*... Connect to the ground.
⑧ The crimping screws connecting all terminals of the electric energy meter to the wires must be tightened, and the wire ends must have clear and obvious signs.
2) Measuring circuit: Connect the electric energy meter to a single-phase 220V AC circuit . The electric energy consumed by the phase load is measured. This wiring method
is called straight-in wiring. The straight-in wiring method of single-head active energy meter is generally divided into two types: jump-in wiring and drop-in wiring.
- Schematic diagram of car cigarette lighter to USB power port
- Lithium battery overcharge, over discharge, short circuit protection circuit design
- Introduction and principle analysis of switching regulated power supply
- Basic connection circuit of signal and power supply composed of ISOll3
- Principles and precautions of active discharge circuit
- Low cost and high performance LED constant current power supply
- A simple positive and negative power supply circuit
- A novel and practical DC low voltage stabilized power supply
- Integrated regulated power supply with continuously adjustable output voltage
- The production of adjustable voltage-stabilized power supply composed of LM317
- Poultry warming temperature control circuit
- Farmland irrigation automatic control circuit b
- Farmland irrigation automatic control circuit a
- Integrated synchronous detector composed of analog multiplier MC1596
- Simple AGC circuit in transistor radio
- Audio function generator composed of ICL8038
- Broadband high frequency power amplifier circuit
- Voltage-controlled voltage source second-order band-pass filter circuit
- Three primary color display circuit
- Sine wave signal generator circuit