Natural gas stove flameout alarm

Source: InternetPublisher:武林萌主 Keywords: Natural gas alarm BSP gas Updated: 2020/01/08

15.<strong>Natural gas</strong> stove flameout<strong>alarm</strong>.gif

The circuit shown is the second type of natural gas (gas)
stove flameout alarm . After the gas stove ignites and burns normally, close
the power switch S. Because the photoresistor RG is irradiated by the strong light of the flame,
its resistance value is very small, the transistors VT1 and VT2 are turned on, the relay
K is closed, its normal contact point II1 K is disconnected, and the music integrated block IC does not
make any sound. But once the gas stove is turned off, the light exposure of RG is greatly
weakened, and its resistance value increases, causing Vri and VTZ to cut off, the relay
K is released, the normally open contact K is closed, and
the power , IC works, and the speaker BL Sounds a music alarm to remind the owner
to close the gas valve in time.
    Except as noted in the circuit, the small relay uses JRX-13F with a working voltage of 12V. Transistor VT3 is 9014, which can
be replaced by 3DG4M, 3DG201, 3DG401 or 3DG8A, B, etc.
    Adjust the potentiometer RP to change the alarm sensitivity.


EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

About Us Customer Service Contact Information Datasheet Sitemap LatestNews


Room 1530, 15th Floor, Building B, No.18 Zhongguancun Street, Haidian District, Beijing, Postal Code: 100190 China Telephone: 008610 8235 0740

Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号