Home > Control Circuits > Non-inductor analog relay circuit diagram

Non-inductor analog relay circuit diagram

Source: InternetPublisher:三岁就很酷 Keywords: Inductive circuit diagram relay circuit Updated: 2021/04/07

As shown in the figure is the principle of the non -inductive analog relay circuit . 

Click to enlarge

working principle:

The 220V power supply provides bias for Q4 and Q3 in turns in the positive and negative half cycles through the load RL, R1, D1~D4, and ZD1; at the same time, it provides power for the photocoupler Q1 through R3, D5~D8. When the front-stage TTL circuit outputs a high-level signal, the photocoupler is turned on during the positive half cycle of the mains power, so a voltage drop occurs across R5, triggering the SCR to turn on, and the load RL is powered to work. The entire circuit functions like a relay, but does not generate reverse induced voltage, thus avoiding the possibility of the load being damaged by high back voltage breakdown. C1 and R6 are pulse absorption components, and R3 plays the role of current limiting.

In order to avoid the 90° phase between the voltage of the thyristor and the power supply of the photocoupler when RL is an inductive load, the power supply of the photocoupler in this circuit is taken from the anode of the SCR and not directly from the mains power supply.
 

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

About Us Customer Service Contact Information Datasheet Sitemap LatestNews


Room 1530, 15th Floor, Building B, No.18 Zhongguancun Street, Haidian District, Beijing, Postal Code: 100190 China Telephone: 008610 8235 0740

Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号