Maintenance skills and common faults of switching power supply

Source: InternetPublisher:Lemontree Keywords: Power supply and other power circuits Zener diodes no DC voltage output Updated: 2020/07/19

The main circuit of the switching power supply is composed of an input electromagnetic interference filter (EMI), a rectifier filter circuit, a power conversion circuit, a PWM controller circuit, and an output rectifier filter circuit. Auxiliary circuits include input over-under voltage protection circuit, output over-under voltage protection circuit, output over-current protection circuit, output short-circuit protection circuit, etc.

Maintenance skills and common faults of switching power supply

1. Maintenance skills

Maintenance of switching power supply can be divided into two steps:

In case of power outage, "look, smell, ask, and measure"

Look: Open the casing of the power supply, check whether the fuse is blown, and then observe the internal conditions of the power supply. If you find burnt spots or broken components on the PCB of the power supply, you should focus on checking the components here and related circuit components.

Smell: Smell if there is a paste smell inside the power supply, and check if there are any burnt components.

Question: I want to ask how the power supply was damaged and whether any illegal operations were performed on the power supply.

t8.png

Measurement: Before powering on, use a multimeter to measure the voltage across the high-voltage capacitor. If the fault is caused by the failure of the switching power supply to vibrate or the open circuit of the switch tube, in most cases, the voltage at both ends of the high-voltage filter capacitor is not discharged. This voltage is more than 300 volts, so be careful. Use a multimeter to measure the forward and reverse resistance at both ends of the AC power cord and the charging condition of the capacitor. The resistance value should not be too low, otherwise there may be a short circuit inside the power supply. Capacitors should be able to charge and discharge. Disconnect the load and measure the resistance to ground of each group of output terminals. Normally, the needle of the meter should swing when charging and discharging the capacitor, and the final indication should be the resistance of the bleeder resistor of that circuit.

Power on test

After powering on, observe whether the power supply has burnt fuses or smoke from individual components. If so, cut off the power supply in time for maintenance.

Measure whether there is 300 volt output at both ends of the high-voltage filter capacitor. If not, focus on checking the rectifier diode, filter capacitor, etc.

Measure whether there is output from the secondary coil of the high-frequency transformer. If not, you should focus on checking whether the switch tube is damaged, whether it is oscillating, whether the protection circuit operates, etc. If so, you should focus on checking the rectifier diode, filter capacitor, and three-way stabilizer on each output side. Pressure tube etc.

If the power supply stops as soon as it is started, the power supply is in a protection state. You can directly measure the voltage of the PWM chip protection input pin. If the voltage exceeds the specified value, it means that the power supply is in a protection state. You should focus on checking the cause of the protection.

2. Common faults

(1)The fuse is blown

Generally, a blown fuse indicates there is a problem with the internal wiring of the power supply. Since the power supply operates at high voltage and high current, fluctuations and surges in the grid voltage will cause the current in the power supply to increase instantaneously and cause the fuse to blow. The focus should be to check the rectifier diode, high-voltage filter electrolytic capacitor, inverter power switch tube, etc. at the power input end to check whether these components have breakdown, open circuit, damage, etc. If the fuse is indeed blown, you should first check the various components on the circuit board to see if the appearance of these components is burned and whether the electrolyte has overflowed. If the above conditions are not found, use a multimeter to measure whether the switch tube has a breakdown or short circuit. . Special attention should be paid to this: when a component is found to be damaged, you must not turn it on directly after replacing it. This is very likely to damage the replaced component because other high-voltage components are still faulty. Be sure to conduct a comprehensive inspection of all high-voltage components in the above circuit. Only after checking and measuring can the fault of the blown fuse be completely eliminated.

(2) No DC voltage output or unstable voltage output

If the fuse is intact, there will be no DC voltage output at all levels under load. This situation is mainly caused by the following reasons: open circuit or short circuit in the power supply, failure of the overvoltage and overcurrent protection circuit, auxiliary power supply failure, oscillation circuit not working, overload of the power supply, rectifier diode in the high-frequency rectifier filter circuit Breakdown, filter capacitor leakage, etc. After measuring the secondary components with a multimeter and ruling out the breakdown of the high-frequency rectifier diode and the load short circuit, if the output is zero at this time, it is certain that the control circuit of the power supply is faulty. If there is some voltage output, it means that the front-end circuit is working normally, and the fault lies in the high-frequency rectifier and filter circuit. The high-frequency filter circuit mainly consists of a rectifier diode and a low-voltage filter capacitor to form a DC voltage output. The breakdown of the rectifier diode will cause the circuit to have no voltage output, and the leakage of the filter capacitor will cause unstable output voltage and other faults. Damaged components can be detected by statically measuring the corresponding components with a multimeter. Example: There is no 24-volt DC output after a certain 24-volt DC motor power supply is powered on. Open the power supply casing and observe that the fuse is not blown and that the circuit board has no obvious burnt spots or cracked components. Measure the AC input terminal when the power is not supplied. The resistance value and DC output terminal resistance are normal, and important components such as switch tubes, rectifier bridges, and rectifier tubes are normal. Therefore, it is judged that there is no possibility of serious internal short circuit, and the protection circuit is estimated to be activated. After checking that this switching power supply uses the U3842 PWM control chip, and searching for relevant information, we found that when the 3-terminal voltage of the U3842 chip is higher than 1 volt, the internal current-sensitive comparator outputs a high level, which resets the PWM latch and causes the output closure. The power-on measurement shows that terminal 3 of U3842 is higher than 1 volt, and terminal 6 has no output. After checking the relevant circuit, it is found that the voltage regulator tube D2 has broken down, as shown in Figure 3, so PC1 is turned on, causing terminal 3 of U3842 to be at a high level, so 6 There is no output at the terminal, the switch tube does not work, and there is no DC output on the DC side. Replace the voltage regulator tube D2 of the same model and the fault is resolved.

t9.png

(3) Poor power supply load capacity

Poor power supply load capacity is a common fault, which usually occurs in old-fashioned or long-working power supplies. The main reasons are aging of components, unstable switching tubes, and lack of timely heat dissipation. You should focus on checking whether the Zener diode is hot and leaking, the rectifier diode is damaged, the high-voltage filter capacitor is damaged, etc. For example: Our factory's near-red laser spectrometer (VECTOR 22) cannot complete the self-test and alarms after starting up, and the mainboard indicator light keeps flashing. After inspection, the DC 5V power supply for the main board of the spectrometer is only about 2.3 volts. Disconnect the load of the 5V DC power supply and measure the 5V DC power supply again. At this time, there is 5V. It is preliminarily judged that the load capacity of the 5V DC power supply is poor, so we disassemble it. The power supply casing is inspected. Since there is a DC 5V output when there is no load, the focus is on checking the output rectifier circuit on the secondary coil side. Connect the 5V power supply to a dummy load and power on for measurement. It is found that 1 and 2 of the three-way voltage regulator 7805 are The voltage between pins is 5.2 volts, but there is 2.3 volts left between pins 2 and 3, as shown in Figure 4. Therefore, it is judged that the performance of the three-way voltage regulator tube 7805 has deteriorated. Replace the three-way voltage regulator tube 7805 to solve the problem.

t10.png

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

About Us Customer Service Contact Information Datasheet Sitemap LatestNews


Room 1530, 15th Floor, Building B, No.18 Zhongguancun Street, Haidian District, Beijing, Postal Code: 100190 China Telephone: 008610 8235 0740

Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号