Motor protector installation steps

Publisher:DelightfulSmileLatest update time:2023-08-22 Source: elecfansKeywords:Motor Reading articles on mobile phones Scan QR code
Read articles on your mobile phone anytime, anywhere

If a thermal relay is used to protect a large motor in a factory, the large wires will break, that is, the screw wiring in and out of the thermal relay will have problems, which will easily cause heating points and fault points. If a motor integrated protector is used instead of a fuse and a thermal relay, because the protector is a through-type, the break points of the large wires can be reduced, thereby reducing heating points and fault points.


When using a motor protector, you must pay attention to the wiring of the control circuit to ensure the normal operation of the machine. It can replace a low-voltage electrical appliance such as a circuit breaker, contactor, thermal relay, fuse, etc.


The installation steps of the motor protector are as follows:

1. According to the installation location requirements and protection function needs, reasonably select the motor protector model and its various protection action parameter settings;

2. Install correctly according to the product manual, connect the terminals correctly according to their purpose, connect the working power supply before the control circuit, and make sure the nominal voltage is consistent with the actual voltage;

3. When the motor protector is equipped with a current ratio transformer, if an ammeter display is required at the equipment site or in the control room, it is best to equip it with another current transformer, otherwise it will affect the current display of the phase equipped with the ammeter;

4. When installing a split protector, do not use the matching transformers and display parts with different numbers together;

5. It can be improved according to user requirements. The output of the analog 4-20 mA interface should match the connected device;

6. Correct grounding. When the low-voltage system is a TN-C protection system, the grounding protection line of the equipment on the load side of the protector must be changed to an independent protective grounding according to the TT system. The neutral line must not be grounded repeatedly and must not be used as a protection line.


Keywords:Motor Reference address:Motor protector installation steps

Previous article:Siemens S7-200SMART series PLC bit related instructions sharing
Next article:What are the types of motor protectors?

Recommended ReadingLatest update time:2024-11-16 22:51

Akamai adds behavioral DDoS protection engine to App & API Protector
New solution leverages machine learning and global intelligence to deliver powerful detection and mitigation capabilities for application-layer DDoS attacks October 23, 2024 – Akamai Technologies, Inc. (Akamai), a cloud service provider responsible for supporting and protecting online life, recent
[Network Communication]
Latest Embedded Articles
Change More Related Popular Components

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

About Us Customer Service Contact Information Datasheet Sitemap LatestNews


Room 1530, 15th Floor, Building B, No.18 Zhongguancun Street, Haidian District, Beijing, Postal Code: 100190 China Telephone: 008610 8235 0740

Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号