How to prepare and select a motor?

Publisher:genius5Latest update time:2022-12-06 Source: elecfansKeywords:Motor Reading articles on mobile phones Scan QR code
Read articles on your mobile phone anytime, anywhere

Motor selection instructions

Are there many friends who are troubled by the problem of motor selection? Today, the editor will explain motor selection to you.


For example: HCM5-132M-7.5-1500-T4-FITS-B3 indicates that the motor is an HCM5 series ultra-high efficiency magnetic-assisted synchronous reluctance motor, frame size 132M, rated power 7.5kW, rated speed 1500r/min, voltage level 3-phase 380V, self-fan cooling, casing material cast iron, top outlet, single keyway, B3 installation method without flange on the bottom foot.

44fefc82-703d-11ed-8abf-dac502259ad0.png

45118082-703d-11ed-8abf-dac502259ad0.png

01

Product range

Benchmarking the national standard motor energy efficiency limit values ​​and energy efficiency levels, we developed two series of products, HCM5 and HCM4, according to the national energy efficiency requirements. The HCM5 series products meet the first-level energy efficiency of the new national standard (GB18613-2020), and the HCM4 series products meet the second-level energy efficiency of the new national standard (GB18613-2020).

INFORMATION

453ca62c-703d-11ed-8abf-dac502259ad0.png

02

Frame No.

The front part of the number indicates the center height, that is, the vertical height from the center of the motor shaft to the plane of the motor base; the back part of the letter indicates the length of the casing, which is generally available in three types: S, M, and L, just like the size of clothes.

INFORMATION

455b467c-703d-11ed-8abf-dac502259ad0.jpg

03

Cooling method

Self-fan cooling (IC411): With self-fan cooling, the fan is coaxial with the motor main shaft and does not require an external power supply. It is commonly used in scenarios where speed regulation is not required or the speed regulation range is small. Generally, the speed regulation range is not less than 60% of the rated speed.

Forced fan cooling (IC416): Built-in fan cooling, the fan and motor shaft are not coaxial, the fan requires an external power supply, variable frequency motors are more commonly used, and are generally used in scenarios where they often run under low speed conditions.

INFORMATION

4567b02e-703d-11ed-8abf-dac502259ad0.png

04

Outlet mode

Facing the shaft extension end, the terminal box at the 12 o'clock position is the top outlet, the terminal box at the 3 o'clock position is the right outlet, and the terminal box at the 9 o'clock position is the left outlet.

INFORMATION

4596d9ee-703d-11ed-8abf-dac502259ad0.png

05

Shaft extension type

Generally there are optical axis, single-key axis and double-key axis. The specific forms are shown in the figure below.

INFORMATION

45b6c8c6-703d-11ed-8abf-dac502259ad0.jpg

N: Optical axis

45c5bbe2-703d-11ed-8abf-dac502259ad0.jpg

S: Single keyway

45d929b6-703d-11ed-8abf-dac502259ad0.jpg

D: Double keyway

06

Installation

There are many ways to install motors, mainly horizontal and vertical.

The most commonly used installation methods are B3, B5, B35, and V1.

1. B3: with base, without direct mounting flange;

2. B5: no foot, with direct mounting flange;

3. B35: with base and direct mounting flange;

4. V1: Install vertically like B5 motor.

INFORMATION

Common installation methods

45ebca26-703d-11ed-8abf-dac502259ad0.png

460f3fe2-703d-11ed-8abf-dac502259ad0.png

Other installation methods

46202cee-703d-11ed-8abf-dac502259ad0.png


Keywords:Motor Reference address:How to prepare and select a motor?

Previous article:Design and production of inverter maintenance power supply
Next article:Ten inverter maintenance methods

Latest Embedded Articles
Change More Related Popular Components

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

About Us Customer Service Contact Information Datasheet Sitemap LatestNews


Room 1530, 15th Floor, Building B, No.18 Zhongguancun Street, Haidian District, Beijing, Postal Code: 100190 China Telephone: 008610 8235 0740

Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号